Improved resolution in dipolar NMR spectra using constant time evolution PISEMA experiment
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index; 2 of the 27 sources its claims cite were checked for support.
Abstract
The atomic structure of small molecules and polypeptides can be attained from anisotropic NMR parameters such as dipolar couplings (DC) and chemical shifts (CS). Separated local field experiments resolve DC and CS correlations into two dimensions. However, crowded NMR spectra represent a significant obstacle for the complete resolution of these anisotropic parameters. Using the PISEMA (Polarization Inversion Spin Exchange at the Magic Angle) experiment as a foundation, we designed new pulse schemes that use a constant time evolution in the dipolar (indirect) dimension to measure DC and CS correlations at high resolution. We demonstrated this approach on a 4-pentyl-4′-cyanobiphenyl (5CB) liquid crystal sample, achieving a resolution enhancement ranging from 30 to 60 % for the resonances in the dipolar dimension. These new experiments open the possibility of obtaining significant resolution enhancement for multidimensional NMR experiments carried out on oriented liquid crystalline samples as well as oriented membrane proteins.
Overview
CoChat Summary
TL;DR
The authors introduce constant-time (CT) evolution into PISEMA and sensitivity-enhanced PISEMA (SECT-PISEMA) to improve resolution in the dipolar dimension of separated local field NMR. On a 5CB liquid crystal sample, CT evolution enhanced dipolar resolution by 30–60%, and SECT-PISEMA narrowed lines by 100–250 Hz versus conventional PISEMA while improving sensitivity.
Key findings
- CT-PISEMA and SECT-PISEMA use constant time evolution in the dipolar indirect dimension, implemented by refocusing the dipolar Hamiltonian in the doubly tilted rotating frame. For the 5CB liquid crystal, CT evolution reduced line widths with a resolution enhancement ranging from 30 to 60% across the spectrum.
- In SECT-PISEMA, dipolar lines were narrowed by 100 to 250 Hz with respect to conventional PISEMA. The constant-time dipolar oscillations of CT- and SECT-PISEMA were less affected by relaxation than conventional PISEMA.
- SECT-PISEMA sensitivity was ~10 to 30% higher than PISEMA except for carbons 1 and 1′, while the gain over CT-PISEMA ranged from 15 to 35%. The loss of sensitivity for CT-PISEMA was negligible for carbons 2′, 3′, and 4′.
- The sine dipolar spectra showed a drastically reduced zero-frequency peak, making them useful for measuring small dipolar couplings often obliterated by truncation artifacts of the intense zero-frequency peak.
Methods
- Pulse sequence design and theory: CT evolution was incorporated into PISEMA and SE-PISEMA; the dipolar Hamiltonian sign was inverted with 180° pulses, and SECT-PISEMA alternated the phase φ of a 90° pulse on the I spin between y and −y to detect cosine- and sine-modulated dipolar coherences.
- Sample and acquisition: experiments used an oriented 4-pentyl-4′-cyanobiphenyl (5CB) liquid crystal sample on a 700 MHz VNMRS spectrometer at 25°C, with 10 ms acquisition time, 6 s recycle delay, and 5 ms CP contact time. Conventional PISEMA used 64 t1 increments, whereas CT-PISEMA and SECT-PISEMA used 21 t1 increments; SECT-PISEMA acquired two interleaved data sets with φ = y and −y.
- Processing and analysis: data were processed with forward linear prediction of the t1 signal up to 128 points and a 90° phase-shifted sine bell window in F1 and F2; PISEMA and CT-PISEMA t1 dimensions were processed in real mode, while SECT-PISEMA used Rance-Kay mode. Resolution was assessed by comparing 1D dipolar cross-section line widths and signal decay in the indirect dimension.
Limitations
- Stated: CT evolution reduces signal intensity, which can be exacerbated by relaxation effects for specific resonances; the CT period should be optimized with awareness of the relaxation properties of the system. For 5CB, fast relaxation of carbons 1, 3, and 4′ forced the total evolution time T to 1280 μs, corresponding to 21 increments.
- Stated: the zero-frequency peak remains present, probably caused by pulse imperfections, though drastically reduced; sine-CT-PISEMA zero-frequency components are dispersive due to imaginary Fourier transformation, and the last trace was slightly distorted from pulse imperfection due to a large 13C offset (35 ppm for resonance 1′).
- Stated/evident: resolution enhancement was demonstrated only on a 5CB liquid crystalline molecule; the authors anticipate a significant contribution for congested dipolar spectra of membrane proteins aligned in magnetically aligned lipid bicelles, but do not demonstrate that here. Evident: the study uses a single sample, field, and temperature, with no membrane-protein validation.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
1 Valid · 1 Not valid · 13 Not checked · 31 Own results and interpretations
At least one cited source doesn’t support this claim or points to a different paper, and none confirmed it — see the verdicts below.
In the paper
“The pulse scheme (SECT-PISEMA) is reported in Figure 1C and allows one to detect both cosine and sine modulated dipolar coherences in a single scan right after the CT period(23, 24).”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > THEORY
What the sources say
- Disputedcites [23] Gopinath T Veglia G J Am Chem Soc 131 2009 5754 19351170 PMC3481552 sourceExperimental — accuracy not yet measured
Our copy of Gopinath & Veglia (2009) describes SE-PISEMA, not 'SECT-PISEMA', and its detection step is explicitly two-scan: after t1 evolution and the (90)°(I,S) pulse plus the τ–π–τ dipolar encoding, 'a final π/2 pulse is applied on the S spin with phases x and –x in two separate scans followed by S spin detection... This scheme allows one to detect both sine and cosine dipolar coherences' (Abstract/body, eq. 7). The discussion reinforces this: the scheme 'detects and also uncouples the sine- and cosine-modulated coherences by performing a two-step phase cycle of the last 90° pulse followed by addition and subtraction of the resultant data sets' (eqs. 8–9). So while the source does support detection of both cosine- and sine-modulated dipolar coherences, it contradicts the claim's 'in a single scan right after the CT period' — the source has no coherence-transfer period immediately preceding acquisition and requires two scans per t1 increment. (LLM, conf=0.82)
Checked by a reasoning model — may be wrong.
- Not matchedcites [24] Gopinath T Verardi R Traaseth NJ Veglia G J Phys Chem B 2010 PMC2861489 20349983
More than one paper fits this citation.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Disputed
The cited sources support only part of this claim — read each source’s verdict below.
In the paper
“The atomic structures of both magnetically aligned liquid crystals or polypeptides uniformly aligned in membrane mimetic systems can be obtained by measuring orientational-dependent anisotropic NMR parameters such as dipolar couplings (DC) and chemical shifts (CS) (1, 2, 3, 4, 5).”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > INTRODUCTION
What the sources say
- Not checked yetcites [1] Quine JR Cross TA Chapman MS Bertram R Bull Math Biol 66 2004 1705 15522352 source
Checked before — its earlier verdict is held back until a new check runs.
- Not checked yetcites [2] Ketchem R Roux B Cross T Structure 5 1997 1655 9438865 source
Checked before — its earlier verdict is held back until a new check runs.
- Partly supportedcites [3] Shi L Traaseth NJ Verardi R Cembran A Gao J Veglia G J Biomol NMR 44 2009 195 19597943 PMC2824793 sourceExperimental — accuracy not yet measured
Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.
- Not checked yetcites [4] Bertram R Quine JR Chapman MS Cross TA J Magn Reson 147 2000 9 11042042 source
Checked before — its earlier verdict is held back until a new check runs.
- Not checked yetcites [5] Mo Y Cross TA Nerdal W Biophys J 86 2004 2837 15111401 PMC1304153 source
Checked before — its earlier verdict is held back until a new check runs.
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Not checked yet
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“From the visual inspection of the 2D contours of the 5CB resonances, it is apparent that the 5CB resonances of the PISEMA spectrum have broader dipolar lines than those obtained from both the CT-PISEMA and SECT-PISEMA experiments.”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > RESULTS AND DISCUSSION
hedgedstates an association- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In the CT-PISEMA experiment, the dipolar and zero frequency components are less affected by relaxation (see Results and Discussion).”
- Also stated in: § RESULTS AND DISCUSSION · hedged
“It is apparent, however, that the constant time dipolar oscillation of CT- and SECT-PISEMA is less affected by the relaxation than the conventional PISEMA experiment.”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > THEORY
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Also stated in: § RESULTS AND DISCUSSION · hedged
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“In the SECT-PISEMA experiment, the dipolar lines are narrowed by 100 to 250 Hz with respect to conventional PISEMA experiment.”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > RESULTS AND DISCUSSION
plainstates a cause- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
19 more claims
Create a free account to see all 46 claims and to verify the 20 references still open.
- Probably not a substantial claim. 18
- It may state two separate claims as one. 7
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In static ss-NMR, we designed POE to recover chemical shift or dipolar coupling coherences and convert them into observable terms to enhance the sensitivity of heteronuclear correlations (HET-COR) or separated local field experiments such as PISEMA (polarization inversion spin exchange at magic angle).[5][6][7][8]21”
From Orphan spin operators enable the acquisition of multiple 2D and 3D magic angle spinning solid-state NMR spectra (2013) · cites this paper as [21]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
Each contradiction between two passages listed here was confirmed by an independent check.
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > THEORY
“ρc=2A^(′){Sycos[spisemaωIS(t1^(′)−t1^(″))]e^iωst2}+2B^(′)Sze^iωst2”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > THEORY
“ρ1=A^(′){Szcos[spisemaωIS(t1^(′)−t1^(″))]e^iωst2+sin(cosθmωISτ)Sxsin[spisemaωIS(t1^(′)−t1^(″))]e^iωst2}+B^(′)Sze^iωst2; ρ2=A^(′){Szcos[spisemaωIS(t1^(′)−t1^(″))]e^iωst2−sin(cosθmωISτ)Sxsin[spisemaωIS(t1^(′)−t1^(″))]e^iωst2}+B^(′)Sze^iωst2”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > THEORY
“Where t1^(′)=(T−t1)/2,t1^(″)=(T−t1)/2, and t1 = (i − 1) × duration of one FSLG cycle.”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > THEORY
“Hence, the dipolar evolution takes place for 2× (i − 1) FSLG cycles or DW × (i − 1).”
Rated minor: it would not touch a result — a value no result rests on, a p-value that stays on the same side of the significance level, or a conflict that is clerical, resolved elsewhere in the paper, or outside its own findings.
In the paper
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > EXPERIMENTAL
“The composite (90)° z pulse on the S-channel is obtained by a (90)° y-(180°) x-(90°) −y pulse train of 12 μs”
§ Improved Resolution in Dipolar NMR Spectra Using Constant Time Evolution PISEMA Experiment > THEORY
“a (180)° z pulse on the S spin, where the latter is obtained by a composite pulse (90)° y(180)° x(90)° −y.”
Citations
Cites
Improved spectral resolution in COSY 1H NMR spectra of proteins via double quantum filtering
Rance, M., Sørensen, O. W., Bodenhausen, G., Wagner, G., Ernst, R. R., & Wüthrich, K. (1983) · Biochemical and Biophysical Research Communications · doi:10.1016/0006-291x(83)91225-1 · Cited by 2,312
Investigation of complex networks of spin-spin coupling by two-dimensional NMR
Bax, A., & Freeman, R. (1981) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(81)90287-0 · Cited by 1,225
High-resolution proton solid-state NMR spectroscopy by phase-modulated Lee–Goldburg experiment
Vinogradov, E., Madhu, P. K., & Vega, S. (1999) · Chemical Physics Letters · doi:10.1016/s0009-2614(99)01174-4 · Cited by 466
High-Resolution Heteronuclear Dipolar Solid-State NMR Spectroscopy
Wu, C. H., Ramamoorthy, A., & Opella, S. J. (1994) · Journal of Magnetic Resonance, Series A · doi:10.1006/jmra.1994.1169 · Cited by 434
Vuister, G. W., & Bax, A. (1992) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(92)90144-v · Cited by 400
Transient Oscillations in NMR Cross-Polarization Experiments in Solids
Müller, L., Kumar, A., Baumann, T., & Ernst, R. R. (1974) · Physical Review Letters · doi:10.1103/physrevlett.32.1402 · Cited by 293
Ketchem, R., Roux, B., & Cross, T. (1997) · Structure · doi:10.1016/s0969-2126(97)00312-2 · Cited by 259
Frequency-Switched Lee—Goldburg Sequences in Solids
Bielecki, A., Kolbert, A. C., de Groot, H. J. M., Griffin, R. G., & Levitt, M. H. (1990) · Advances in magnetic and optical resonance · doi:10.1016/b978-0-12-025514-6.50011-3 · Cited by 223
Kovacs, F., & Cross, T. A. (1997) · Biophysical Journal · doi:10.1016/s0006-3495(97)78279-1 · Cited by 196
Hu, J., Asbury, T., Achuthan, S., Li, C., Bertram, R., Quine, J. R., Fu, R., & Cross, T. A. (2007) · Biophysical Journal · doi:10.1529/biophysj.106.090183 · Cited by 194
Research works printed but not linked: 3
- Bax A Freeman R J Mag Res 44 1981 542 561
- Rance M Wagner G Sorensen OW Wuthrich K Ernst RR J Mag Res 59 1984 250 261
- Vuister GW Bax A Bax A J Mag Res 98 1992 428 435
Cited by
Mote, K. R., Gopinath, T., Traaseth, N. J., Kitchen, J., Gor’kov, P. L., Brey, W. W., & Veglia, G. (2011) · Journal of Biomolecular NMR · doi:10.1007/s10858-011-9571-8 · Cited by 40
Self-citationGopinath, T., & Veglia, G. (2013) · The Journal of Chemical Physics · doi:10.1063/1.4803126 · Cited by 39
Self-citationMote, K. R., Gopinath, T., & Veglia, G. (2013) · Journal of Biomolecular NMR · doi:10.1007/s10858-013-9766-2 · Cited by 37
Self-citationSensitivity and resolution enhancement of oriented solid-state NMR: Application to membrane proteins
Gopinath, T., Mote, K. R., & Veglia, G. (2013) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2013.07.004 · Cited by 30
Self-citationGopinath, T., Mote, K. R., & Veglia, G. (2011) · The Journal of Chemical Physics · doi:10.1063/1.3622604 · Cited by 17
Self-citation
Metadata
- Authors
- Gopinath, T., & Veglia, G.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Veglia, Gianluigi
- Venue
- Chemical Physics Letters
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 494
- Issue
- 1-3
- Pages
- 104-110
- ISSN
- 0009-2614 (ISSN-L)
- PMC
- PMC2929988
- OpenAlex
- W2120631579
- Semantic Scholar
- 0396795aacaff62f4efa61a0a6512783b93d65d7
- Cited by
- 10
- References
- 41
- Citations by year
- 2025: 1 · 2017: 1 · 2014: 1 · 2013: 3 · 2012: 2
- FWCI
- 0.87
- Type
- journal article
- Language
- en
- Open access
- green
- pmc.ncbi.nlm.nih.gov
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Chemical Physics Letters (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Heart, Lung, and Blood Institute (K02HL080081)
- National Institute of General Medical Sciences (R01GM064742)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Molecular spectroscopy and chirality
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- dipolar coupling, chemical shift correlation, resolution enhancement, 4-pentyl-4'-cyanobiphenyl, liquid crystals, oriented samples, membrane proteins, multidimensional NMR
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
The claim verdicts this report counts are experimental: their accuracy is not yet measured.
A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Cited sources are checked with a language model’s help (qwen3.8-omni-flash).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.