Coupled Particle-In-Cell and Direct Simulation Monte Carlo method for simulating reactive plasma flows
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Plasma flows with high Knudsen numbers cannot be treated with classic continuum methods, as represented for example by the Navier–Stokes or the magnetohydrodynamic equations. Instead, the more fundamental Boltzmann equation has to be solved, which is done here approximately by particle based methods that also allow for thermal and chemical non-equilibrium. The Particle-In-Cell method is used to treat the collisionless Vlasov–Maxwell system, while neutral reactive flows are treated by the Direct Simulation Monte Carlo method. In this article, a combined approach is presented that allows the simulation of reactive, partially or fully ionized plasma flows. Both particle methods are briefly outlined and the coupling and parallelization strategies are described. As an example, the results of a streamer discharge simulation are presented and discussed in order to demonstrate the capabilities of the coupled method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molecular Gas Dynamics And The Direct Simulation Of Gas Flows
Bird, G. A. (1994) · doi:10.1093/oso/9780198561958.001.0001 · Cited by 7,269
Cited by
Intake design for an Atmosphere-Breathing Electric Propulsion System (ABEP)
Romano, F., Espinosa-Orozco, J., Pfeiffer, M., Herdrich, G., Crisp, N. H., Roberts, P. C. E., Holmes, B. E. A., Edmondson, S., Haigh, S., Livadiotti, S., et al. (2021) · Acta Astronautica · doi:10.1016/j.actaastro.2021.06.033 · Cited by 95
“PICLas is a numerical tool for simulating non-equilibrium gas and plasma flows developed by the Institute of Space Systems (IRS) and the Institute of Aerodynamics and Gasdynamics (IAG) at U. Stuttgart [43]. d d c g 𝑣 - h r f i The code is a three-dimensional, parallelized simulation framework for the coupling of, amon…”
MethodSelf-citationBinder, T., Boldini, P. C., Romano, F., Herdrich, G., & Fasoulas, S. (2016) · AIP Conference Proceedings · doi:10.1063/1.4967689 · Cited by 29
Self-citationGueroult, R., Fubiani, G., & Garrigues, L. (2018) · Frontiers in Physics · doi:10.3389/fphy.2018.00128 · Cited by 1
“To address these limitations and guarantee self-consistent results, one has to simulate both charged particles and neutrals through the entire range of timescales, from electron’s to neutral’s [84].”
Background
Metadata
- Authors
- Munz, C.-D., Auweter-Kurtz, M., Fasoulas, S., Mirza, A., Ortwein, P., Pfeiffer, M., & Stindl, T.
- Venue
- Comptes Rendus. Mécanique
- Publisher
- MathDoc/Centre Mersenne
- Published
- 2014-08-08
- Volume
- 342
- Issue
- 10-11
- Pages
- 662-670
- ISSN
- 1873-7234 (ISSN-L)
- 1631-0721
- OpenAlex
- W2082103989
- Cited by
- 65
- References
- 1
- FWCI
- 12.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.