A review on antimicrobial strategies in mitigating biofilm-associated infections on medical implants
The DOI matches its Crossref record; 247 of the 247 references it cites were found in a registry or an index.
Abstract
Biomedical implants are crucial in providing support and functionality to patients with missing or defective body parts. However, implants carry an inherent risk of bacterial infections that are biofilm-associated and lead to significant complications. These infections often result in implant failure, requiring replacement by surgical restoration. Given these complications, it is crucial to study the biofilm formation mechanism on various biomedical implants that will help prevent implant failures. Therefore, this comprehensive review explores various types of implants (e.g., dental implant, orthopedic implant, tracheal stent, breast implant, central venous catheter, cochlear implant, urinary catheter, intraocular lens, and heart valve) and medical devices (hemodialyzer and pacemaker) in use. In addition, the mechanism of biofilm formation on those implants, and their pathogenesis were discussed. Furthermore, this article critically reviews various approaches in combating implant-associated infections, with a special emphasis on novel non-antibiotic alternatives to mitigate biofilm infections.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Surface coatings (GL13K peptide, AGXX®) reduce bacterial adhesion by 40–94% on medical devices [298,300].”
From Staphylococcus aureus: A Review of the Pathogenesis and Virulence Mechanisms (2025) · cites this paper as [298]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2 retracted
Items 201–247 of 247
Prevention of pacemaker infections with perioperative antimicrobial treatment: an in vitro study
Marsch, G., Mashaqi, B., Burgwitz, K., Bisdas, T., Knigina, L., Stiesch, M., Haverich, A., & Kuehn, C. (2013) · EP Europace · doi:10.1093/europace/eut222 · Cited by 17
Shawcross, J. T., Bakhai, A., Ansaripour, A., Armstrong, J., Lewis, D., Agg, P., de Godoy, R. F., & Blunn, G. W. (2017) · Open Heart · doi:10.1136/openhrt-2015-000357 · Cited by 15
Krishnan, G., Naik, D. G., Uppoor, A. S., Nayak, S. U., Baliga, S., & Maddi, A. (2020) · PeerJ · doi:10.7717/peerj.8441 · Cited by 15
Yang, L., Lan, X., He, Z., Yin, A., Jin, W., Hu, Q., & Wang, Y. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109803 · Cited by 15
Bioactive surface coating for preventing mechanical heart valve thrombosis
Lancellotti, P., Aqil, A., Musumeci, L., Jacques, N., Ditkowski, B., Debuisson, M., Thiry, M., Dupont, J., Gougnard, A., Sandersen, C., et al. (2023) · Journal of Thrombosis and Haemostasis · doi:10.1016/j.jtha.2023.05.004 · Cited by 11
Ng, A. W. R., Li, L., Ng, E. W. L., Li, C., & Qiao, Y. (2023) · ACS Infectious Diseases · doi:10.1021/acsinfecdis.3c00115 · Cited by 8
Abouleish, Y. Z., Oldfield, E. C., & Marik, P. E. (2020) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2020.423
Multifocal intraocular lenses: An overview
ALIO, J. L., Plaza-Puche, A. B., Férnandez-Buenaga, R., Pikkel, J., & Maldonado, M. J. (2017) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2017.03.005
Implants and Breast Pocket Irrigation: Outcomes of Antibiotic, Antiseptic, and Saline Irrigation
Awad, A. N., Heiman, A. J., & Patel, A. (2021) · Aesthetic Surgery Journal · doi:10.1093/asj/sjab181
A systematic review of the use of titanium versus stainless steel implants for fracture fixation
Barber, C. C., Burnham, M., Ojameruaye, O., & McKee, M. D. (2021) · OTA International The Open Access Journal of Orthopaedic Trauma · doi:10.1097/oi9.0000000000000138
Benito-González, F., Benito, J. I., Sanchez, L. A. G., Estévez-Alonso, J. S., Herrera, Á. M. M., & Caletrío, Á. B. (2014) · Cochlear Implants International · doi:10.1179/1754762814y.0000000072
Antibacterial and magnetic response of site-specific cobalt incorporated hydroxyapatite
Bhattacharjee, A., Gupta, A., Verma, M., Murugan, P. A., Sengupta, P., Matheshwaran, S., Manna, I., & Balani, K. (2019) · Ceramics International · doi:10.1016/j.ceramint.2019.08.291
Incidence and indications for revision cochlear implant surgery in adults and children
Brown, K. D., Connell, S. S., Bałkany, T. J., Eshraghi, A. A., Telischi, F. F., & Angeli, S. I. (2008) · The Laryngoscope · doi:10.1002/lary.20012
Chaftari, A., Hachem, R. Y., Szvalb, A. D., Taremi, M., Granwehr, B. P., Viola, G. M., Sapna, A., Assaf, A. D., Numan, Y., Shah, P., et al. (2017) · Antimicrobial Agents and Chemotherapy · doi:10.1128/aac.00091-17
Chong, C. Y., Ong, R. Y. L., Seah, V. X. F., Tan, N. W., Chan, M., Soh, S. Y., Ong, C., Lim, A. S., & Thoon, K. (2019) · Journal of Paediatrics and Child Health · doi:10.1111/jpc.14506
Antibacterial titanium dioxide coatings for CoCrMo orthopaedic implants
D’Agostino, A., Bertolini, M. N., Bono, N., Pavarini, M., Tarsini, P., Candiani, G., Nardo, L. D., & Chiesa, R. (2022) · Applied Surface Science · doi:10.1016/j.apsusc.2022.155300
Dzhemiliev, A., Kizub, D., Welten, V. M., Shabat, G., Huivaniuk, I., Bielichenko, S., Semeniv, S., Zmijewski, P. V., Voitiv, Y. Y., Usenko, O., et al. (2023) · Annals of Surgery · doi:10.1097/sla.0000000000005873
Hemodialyzer Reuse and Gram-Negative Bloodstream Infections
Edens, C., Wong, J., Lyman, M., Rizzo, K. R., Nguyen, D. B., Blain, M. L. M., Horwich-Scholefield, S., Moulton-Meissner, H. A., Epson, E. E., Rosenberg, J. B., et al. (2016) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2016.09.022
El‐Chami, M. F., Mayotte, J., Bonner, M., Holbrook, R., Stromberg, K. D., & Sohail, M. R. (2020) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.14362
Tea tree oil: in vitro efficacy in otitis externa
Farnan, T., McCallum, J., Awa, A.-K., Khan, A. D., & Hall, S. J. (2005) · The Journal of Laryngology & Otology · doi:10.1258/0022215053561495
Degradable Chitosan-Collagen Composites Seeded with Cells as Tissue Engineered Heart Valves
Fu, J., Zhao, M., Lin, Y.-R., Tian, X., Wang, Y.-D., Wang, Z., & Wang, L. (2016) · Heart Lung and Circulation · doi:10.1016/j.hlc.2016.05.116
Prophylactic effect of clarithromycin in skin flap complications in cochlear implants surgery
García‐Valdecasas, J. C., Jiménez‐Moleón, J. J., Sainz, M., Fornieles, C., & Ballesteros, J. M. (2009) · The Laryngoscope · doi:10.1002/lary.20603
Greenstein, G., & Cavallaro, J. (2014) · The Journal of the American Dental Association · doi:10.14219/jada.2014.28
The Use of a Novel Antimicrobial Implant Coating In Vivo to Prevent Spinal Implant Infection
Hegde, V. V., Park, H. Y., Dworsky, E. M., Zoller, S. D., Xi, W., Johansen, D., Loftin, A. H., Hamad, C. D., Segura, T., & Bernthal, N. M. (2019) · Spine · doi:10.1097/brs.0000000000003279
Holmes, C. J., Degremont, A., Kubey, W., Straka, P., & Man, N. K. (2004) · Blood Purification · doi:10.1159/000080791
Kariya, S., Nakatani, M., Ono, Y., Maruyama, T., Ueno, Y., Komemushi, A., & Tanigawa, N. (2020) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-020-02408-6
Complications in pediatric cochlear implant surgery
Kempf, H.-G., Johann, K., & Lenarz, T. (1999) · European Archives of Oto-Rhino-Laryngology · doi:10.1007/s004050050124
Antimicrobial effect of alexidine and chlorhexidine against Enterococcus faecalis infection
Kim, H.-S., Chang, S. W., Baek, S.-H., Han, S. H., Lee, Y., Zhu, Q., & Kum, K. (2013) · International Journal of Oral Science · doi:10.1038/ijos.2013.11
Lucas, T. C., Tessarolo, F., Veniero, P., D’Amato, E., Caola, I., Nollo, G., Huebner, R., & Brunori, G. (2014) · The Journal of Vascular Access · doi:10.5301/jva.5000200
Osseointegration of Cobalt-Chrome Alloy Implants
Mavrogenis, A. F., Papagelopoulos, P. J., & Babis, G. C. (2011) · Journal of Long-Term Effects of Medical Implants · doi:10.1615/jlongtermeffmedimplants.v21.i4.80
Bacterial Biofilms and Increased Bacterial Counts Are Associated with Airway Stenosis
Mazhar, K., Gunawardana, M., Webster, P. C., Hochstim, C. J., Koempel, J. A., Kokot, N., Sinha, U. K., Rice, D. H., & Baum, M. M. (2014) · Otolaryngology · doi:10.1177/0194599814522765
In vitro biofilm distribution on the intraocular lens surface of different biomaterials
Mazoteras, P., & Casaroli-Marano, R. P. (2015) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2015.05.029
Boron Carbon Nitride (BCN) Nano-Coatings of Central Venous Catheters Inhibits Bacterial Colonization
Naga, V., Nehate, S. D., Saikumar, A. K., & Sundaram, K. B. (2020) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/abb009
Ranch-Lundin, M., Schedin, A., & Björkhem‐Bergman, L. (2021) · Scandinavian Journal of Infectious Diseases · doi:10.1080/23744235.2021.1922752
Sivakumar, S., Sithivinayagam, A., Krishnasamy, B., Govindarajan, D. K., Kothandan, R., & Kandaswamy, K. (2023) · Maejo International Journal of Energy and Environmental Communication · doi:10.54279/mijeec.v5i1.249294
Self-citationSivaramakrishnan, M., Sharavanan, V. J., Govindarajan, D. K., Meganathan, Y., Devaraj, B. S., Sivarajasekar, N., Kothandan, R., & Kandaswamy, K. (2019) · SN Applied Sciences · doi:10.1007/s42452-019-0221-1
Self-citationTapia-Rodríguez, M. R., Bernal-Mercado, A. T., Gutiérrez-Pacheco, M. M., Vázquez-Armenta, F. J., Hernández‐Mendoza, A., González-Aguilar, G. A., Martínez‐Téllez, M. Á., Nazzaro, F., & Ayala-Zavala, J. F. (2019) · Journal of Cell Communication and Signaling · doi:10.1007/s12079-019-00516-8
Antimicrobial coating agents: can biofilm formation on a breast implant be prevented?
van Heerden, J., Turner, M. L., Hoffmann, D., & Moolman, J. (2008) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2007.09.044
Anti-fouling strategies for central venous catheters
Wallace, A., Albadawi, H., Patel, N., Khademhosseini, A., Zhang, Y. S., Naidu, S., Knuttinen, G., & Öklü, R. (2017) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.09.18
Werner, L. P. (2020) · Ophthalmology · doi:10.1016/j.ophtha.2020.06.055
Temperature-sensitive tribological performance of titanium alloy lubricated with PNIPAM microgels
Xu, Y., Bao, Y., Liu, Z., Zheng, Q. S., Dong, Y., Song, R., & Yang, B. (2021) · Applied Surface Science · doi:10.1016/j.apsusc.2021.151392
Yang, C.-C., Lin, C.-C., Liao, J., & Yen, S. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.01.038
Conservative Management of Infections in Cochlear Implant Recipients
Yu, K. C. Y., Hegarty, J. L., Gantz, B. J., & Lalwani, A. K. (2001) · Otolaryngology · doi:10.1067/mhn.2001.116444
Zhang, S., Liang, X., Gadd, G. M., & Zhao, Q. (2019) · ACS Applied Bio Materials · doi:10.1021/acsabm.9b00814
F-doped TiO2 microporous coating on titanium with enhanced antibacterial and osteogenic activities
Zhou, J., Li, B., & Han, Y. (2018) · Scientific Reports · doi:10.1038/s41598-018-35875-6
Vascular Catheter-Related Infection and Sepsis
Donelli, G. (2006) · Surgical Infections · doi:10.1089/sur.2006.7.s2-25
Late skin flap failure following cochlear implantation
Trinidade, A., Rowlands, G., Obholzer, R., & Lavy, J. (2008) · Cochlear Implants International · doi:10.1179/cim.2008.9.3.167
Research works printed but not linked: 23
- Aherwar, 2016, Cobalt based alloy: a better choice biomaterial for hip implants, Trends Biomater. Artif. Organs, 30
- Braem, 2023, Biomaterial strategies to combat implant infections: new perspectives to old challenges, Int. Mater. Rev., 1
- Chen, 2023, Antibacterial coatings on orthopedic implants, Mater. Today Bio
- Dong, 2005, Quorum sensing and quorum-quenching enzymes, J. Microbiol., 43, 101
- Döring, 2018, The diagnosis and treatment of pacemaker-associated infection, Dtsch. Arztebl. Int., 115, 445
- Fiori-Duarte, 2023, Modulation of Pseudomonas aeruginosa quorum sensing by ajoene through direct competition with small RNAs for binding at the proximal site of Hfq–A structure-based perspective, Gene, 877
- Freedman, 2020, Persistent Cutibacterium (Formerly Propionibacterium) acnes bacteremia and refractory endocarditis in a patient with retained implantable pacemaker leads, Case Rep. Infect. Dis., 2020
- Govindarajan, 2023, Green synthesis of silver micro-and nano-particles using phytochemical extracts of Cymbopogon citratus exhibits antibacterial properties, Mater. Today: Proc., 76, 103
- Guleri, 2017, Effectiveness and safety of daptomycin in patients with infective endocarditis undergoing heart valve replacement: a subgroup analysis from real-world data, Ther. Adv. Infect. Dis., 4, 41
- Kandi, 2020, Implant-associated infections: a review of the safety of cardiac implants, Cureus, 12
- Li, 2022, Synergistic effects of silver nanoparticles and cisplatin in combating inflammation and hyperplasia of airway stents, Bioact. Mater., 9, 266
- Lim, 2021, Quorum quenching activity of Andrographis paniculata (Burm f.) Nees andrographolide compounds on metallo-β-lactamase-producing clinical isolates of Pseudomonas aeruginosa PA22 and PA247 and their effect on lasR gene expression, Heliyon, 7
- Mallela, 2004, Trends in cardiac pacemaker batteries, Indian Pacing Electrophysiol. J., 4, 201
- Matassi, 2013, Porous metal for orthopedics implants, Clin. Cases Miner. Bone Metabol., 10, 111
- Mohsen, 2020, Update on the adverse effects of antimicrobial therapies in community practice, Can. Fam. Physician, 66, 651
- Rodriguez, 2013, Management of cardiac device-related infections: a review of protocol-driven care, Int. J. Cardiol., 166, 55, 10.1016/j.ijcard.2011.09.071 · DOI
- Santos, 2011, Biofilm on artificial pacemaker: fiction or reality?, Arq. Bras. Cardiol., 97, e113, 10.1590/S0066-782X2011001400018 · DOI · Paper page
- Simon, 1991, An overview of implant materials, Acta Orthop. Belg., 57, 1
- Singhal, 2013, Bioprosthetic heart valves: impact of implantation on biomaterials, Int. Sch. Res. Notices, 2013
- Waters, 2022, Infectious outcomes of fibrin sheath disruption in tunneled dialysis catheters, J. Vasc. Access
- Wei, 2019, Responsive and synergistic antibacterial coatings: fighting against bacteria in a smart and effective way, Adv. Healthc. Mater., 8
- Weiland-Bräuer, 2021, Friends or foes—Microbial interactions in nature, Biology (Basel), 10, 496
- Zhang, 2022, Antibiofilm activity of allicin and quercetin in treating biofilm-associated orthopaedics infection, Appl. Biochem. Biotechnol., 1
Cited by
Staphylococcus aureus: A Review of the Pathogenesis and Virulence Mechanisms
Touaitia, R., Mairi, A., Ibrahim, N. A., Basher, N. S., Idres, T., & Touati, A. (2025) · Antibiotics · doi:10.3390/antibiotics14050470 · Cited by 273
Metadata
- Authors
- Kadirvelu, L., Sivaramalingam, S. S., Jothivel, D., Chithiraiselvan, D. D., Karaiyagowder Govindarajan, D., & Kandaswamy, K.
- Venue
- Current Research in Microbial Sciences
- Publisher
- Elsevier BV
- Published
- 2024
- Volume
- 6
- Pages
- 100231
- ISSN
- 2666-5174
- Cited by
- 60
- References
- 247
- Language
- en
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by-nc-nd/4.0/ (vor, 65 d)
- Funders
- Department of Science and Technology, Ministry of Science and Technology, India
- Ministry of Science and Technology
- Science and Engineering Research Board (SRG/2019/000094)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.