Integration of IEC 61850 SCL and OPC UA to improve interoperability in Smart Grid environment
The DOI matches its Crossref record.
Abstract
Integration of the several heterogeneous and geographically dispersed actors in Smart Grid environment is currently hampered by the usage of non-interoperable and proprietary automation solutions. Standards-compliant integration is an indispensable requirement for successful Smart Grid automation. The international standard IEC 61850 has been recognised as one of the fundamental components for reference Smart Grid architectures. Nevertheless, certain parts of the IEC 61850 definitions seem inadequate to compete with the accelerated Smart Grid evolution. For this reason, current literature presents solutions able to surpass the main limitations of the standard, improving harmonisation in Smart Grid; among them, there is integration of IEC 61850 data model with OPC UA information model. According to the current literature, integration of IEC 61850 with OPC UA does not involve the IEC 61850 engineering process, based on a particular language called Substation Configuration description Language (SCL). The paper will present a common Smart Grid scenario where interoperability could be improved extending the idea of the integration between IEC 61850 and OPC UA also to the SCL-based engineering capabilities of the IEC 61850 standard. The paper will present a proposal of mapping between IEC 61850 SCL and OPC UA, describing the relevant algorithm, its implementation and performance evaluation. Proposal of integration of IEC 61850 SCL with OPC UA information model in a Smart Grid environmentDefinition of OPC UA ObjectTypes able to represent IEC 61850 SCL elementsDefinition of mapping models between IEC 61850 SCL elements and OPC UA objectsDefinition of an algorithm for the mapping of IEC 61850 SCL elements to OPC UA objectsImplementation and performance evaluation of the mapping algorithm
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
González, I., Calderón, A. J., Figueiredo, J., & Sousa, J. M. C. (2019) · Electronics · doi:10.3390/electronics8050510 · Cited by 103
Novel remote monitoring platform for RES-hydrogen based smart microgrid
González, I., Calderón, A. J., & Andújar, J. M. (2017) · Energy Conversion and Management · doi:10.1016/j.enconman.2017.06.031 · Cited by 52
Cryptographic Considerations for Automation and SCADA Systems Using Trusted Platform Modules
Tidrea, A., Korodi, A., & Silea, I. (2019) · Sensors · doi:10.3390/s19194191 · Cited by 24
“The discovery of the virus in 2010 raised awareness in respect to security issues in industrial control systems.”
Background
Metadata
- Authors
- Cavalieri, S., & Regalbuto, A.
- Venue
- Computer Standards & Interfaces
- Publisher
- Elsevier BV
- Published
- 2016-08
- Volume
- 47
- Pages
- 77-99
- ISSN
- 0920-5489 (ISSN-L)
- OpenAlex
- W1942117396
- Cited by
- 41
- References
- 0
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.