Application of microCT to the non-destructive testing of an additive manufactured titanium component
Open accessThe DOI matches its Crossref record.
Abstract
In this paper the application of X-ray microCT to the non-destructive testing of an additive manufactured titanium alloy component of complex geometry is demonstrated. Additive manufacturing of metal components is fast growing and shows great promise, yet these parts may contain defects which affect mechanical properties of the components. In this work a layered form of defect is found by microCT, which would have been very difficult or impossible to detect by other non-destructive testing methods due to the object complexity, defect size and shape and because the pores are entirely contained inside the object and not connected to the surface. Additionally, this test part was subjected to hot isostatic pressing (HIPPING) and subsequently scanned. Comparing before and after scans by alignment of the volumes allows visualization and quantification of the pore size changes. The application of X-ray microCT to additive manufacturing is thus demonstrated in this example to be an ideal combination, especially for process improvements and for high value components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
du Plessis, A., Yadroitsev, I., Yadroitsava, I., & Le Roux, S. G. (2018) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2018.0060 · Cited by 550
Beautiful and Functional: A Review of Biomimetic Design in Additive Manufacturing
du Plessis, A., Broeckhoven, C., Yadroitsava, I., Yadroitsev, I., Hands, C. H., Kunju, R., & Bhate, D. (2019) · Additive Manufacturing · doi:10.1016/j.addma.2019.03.033 · Cited by 448
“The HIP process closes pores and improves the microstructure, 11 but it is important to realize that not all pores are necessarily closed by HIP: it has been shown that 12 pores connected to the surface do not close properly, and is detectable by microCT [155].”
BackgroundSeifi, M., Gorelik, M., Waller, J., Hrabe, N., Shamsaei, N., Daniewicz, S., & Lewandowski, J. J. (2017) · JOM · doi:10.1007/s11837-017-2265-2 · Cited by 422
Fracture and fatigue in additively manufactured metals
Becker, T. H., Kumar, P., & Ramamurty, U. (2021) · Acta Materialia · doi:10.1016/j.actamat.2021.117240 · Cited by 377
du Plessis, A., & Macdonald, E. (2020) · Additive Manufacturing · doi:10.1016/j.addma.2020.101191 · Cited by 246
X-Ray Computed Tomography Inspection in Metal Additive Manufacturing: The Role of Witness Specimens
du Plessis, A., Waller, J. M., le Roux, S. G., Yadroitsava, I., Yadroitsev, I., Els, J., & Prinsloo, J. (2020) · Structural Integrity of Additive Manufactured Materials and Parts · doi:10.1520/stp163120190109 · Cited by 9
Self-citation
Metadata
- Authors
- du Plessis, A., le Roux, S. G., Els, J., Booysen, G., & Blaine, D. C.
- Venue
- Case Studies in Nondestructive Testing and Evaluation
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 4
- Pages
- 1-7
- ISSN
- 2214-6571 (ISSN-L)
- OpenAlex
- W2206169207
- Cited by
- 78
- References
- 0
- FWCI
- 6.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.