Academy of Dental Materials guidance—Resin composites: Part II—Technique sensitivity (handling, polymerization, dimensional changes)
Open accessThe DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.
Abstract
OBJECTIVE The objective of this work, commissioned by the Academy of Dental Materials, was to review and critically appraise test methods to characterize properties related to critical issues for dental resin composites, including technique sensitivity and handling, polymerization, and dimensional stability, in order to provide specific guidance to investigators planning studies of these properties. METHODS The properties that relate to each of the main clinical issues identified were ranked in terms of their priority for testing, and the specific test methods within each property were ranked. An attempt was made to focus on the tests and methods likely to be the most useful, applicable, and supported by the literature, and where possible, those showing a correlation with clinical outcomes. Certain methods are only briefly mentioned to be all-inclusive. When a standard test method exists, whether from dentistry or another field, this test has been identified. Specific examples from the literature are included for each test method. RESULTS The properties for evaluating resin composites were ranked in the priority of measurement as follows: (1) porosity, radiopacity, sensitivity to ambient light, degree of conversion, polymerization kinetics, depth of cure, polymerization shrinkage and rate, polymerization stress, and hygroscopic expansion; (2) stickiness, slump resistance, and viscosity; and (3) thermal expansion. SIGNIFICANCE The following guidance is meant to aid the researcher in choosing the most appropriate test methods when planning studies designed to assess certain key properties and characteristics of dental resin composites, specifically technique sensitivity and handling during placement, polymerization, and dimensional stability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances and Developments in Composite Dental Restorative Materials
Cramer, N. B., Stansbury, J. W., & Bowman, C. N. (2011) · Journal of Dental Research · doi:10.1177/0022034510381263 · Cited by 716 · cited 1×
“There are diverse examples of classes of monomers other than methacrylates under development for dental materials application such as (meth)acrylamide, thiol-ene, azide-alkyne and others [26, 27].”
BackgroundSelf-citationDetermination of double bond conversion in dental resins by near infrared spectroscopy
Stansbury, J. W., & Dickens, S. H. (2001) · Dental Materials · doi:10.1016/s0109-5641(00)00062-2 · Cited by 524 · cited 1×
“In chain-growth copolymerizations, the conversion of each comonomer can differ [31-33] while in step-growth polymerization processes, such as thiol-ene reactions, conversion of the respective complementary functional groups can diverge due to potential homopolymerization of one of the components or off-stoichiometric…”
BackgroundSelf-citationClinical challenges and the relevance of materials testing for posterior composite restorations
Sarrett, D. C. (2005) · Dental Materials · doi:10.1016/j.dental.2004.10.001 · Cited by 453 · cited 1×
“Voids are significant in that they can degrade mechanical and esthetic properties of resin composite restorations [14].”
BackgroundCalibration of FTIR conversion analysis of contemporary dental resin composites
Rueggeberg, F. A., Hashinger, D. T., & Fairhurst, C. W. (1990) · Dental Materials · doi:10.1016/s0109-5641(05)80005-3 · Cited by 312 · cited 1×
“In studies designed to look specifically at the reliability of varied baseline construction protocols, mixtures of active methacrylate monomers along with hydrogenated analogs of the same monomers in known proportions were used to determine the best fit [49, 50].”
MethodPhoto-polymerization shrinkage-stress kinetics in resin-composites: methods development
Watts, D. (2003) · Dental Materials · doi:10.1016/s0109-5641(02)00123-9 · Cited by 268 · cited 1×
“It has been widely used in both academia and industry for more than a decade [104, 109-111].”
MethodSelf-citationPolymerization shrinkage of methacrylate esters
Patel, M. P., Braden, M., & Davy, K. W. M. (1987) · Biomaterials · doi:10.1016/0142-9612(87)90030-5 · Cited by 258 · cited 1×
“(Meth)acrylate and epoxy monomers are well characterized with respect to their polymerization shrinkage behavior and these shrinkage coefficients are available in the literature [60-62].”
BackgroundVolume contraction in photocured dental resins: The shrinkage-conversion relationship revisited
Dewaele, M., Truffier-Boutry, D., Devaux, J., & Leloup, G. (2006) · Dental Materials · doi:10.1016/j.dental.2005.03.014 · Cited by 254 · cited 1×
“(Meth)acrylate and epoxy monomers are well characterized with respect to their polymerization shrinkage behavior and these shrinkage coefficients are available in the literature [60-62].”
BackgroundPolymerization stress-is it clinically meaningful
Ferracane, J. L., & Hilton, T. J. (2016) · Dental Materials · doi:10.1016/j.dental.2015.06.020 · Cited by 236
Beasley, M. M., Bartelink, E. J., Taylor, L., & Miller, R. M. (2014) · Journal of Archaeological Science · doi:10.1016/j.jas.2014.03.008 · Cited by 228 · cited 1×
“Fortunately, there are several alternative approaches available for the collection of mid-IR spectra that avoid the transmission mode specimen restrictions [45] (Figure 5).”
BackgroundOxygen Inhibition in Dental Resins
Gauthier, M. A., Stangel, I., Ellis, T. H., & Zhu, X. X. (2005) · Journal of Dental Research · doi:10.1177/154405910508400808 · Cited by 180 · cited 1×
“The use of confocal Raman depth profiling capabilities has been used to probe oxygen-inhibited surface layers [54] as well as a source of depth-dependent data on both polymer composition and conversion in dental adhesives.”
Cited by
Dental resin composites: A review on materials to product realizations
Cho, K., Rajan, G., Farrar, P., Prentice, L., & Prusty, B. G. (2022) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2021.109495 · Cited by 283
Metadata
- Authors
- Ferracane, J. L., Hilton, T. J., Stansbury, J. W., Watts, D. C., Silikas, N., Ilie, N., Heintze, S., Cadenaro, M., & Hickel, R.
- Venue
- Dental Materials
- Publisher
- Elsevier BV
- Published
- 2017-11
- Volume
- 33
- Issue
- 11
- Pages
- 1171-1191
- ISSN
- 0109-5641 (ISSN-L)
- OpenAlex
- W2754438546
- Cited by
- 179
- References
- 43
- FWCI
- 17.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.