The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Diastolic stress echocardiography: A novel noninvasive diagnostic test for diastolic dysfunction using supine bicycle exercise Doppler echocardiography
Open accessAbstract
Left ventricular filling pressures can be estimated reliably by combining mitral inflow early diastolic velocity (E) and annulus velocity (E'). An increased E/E' ratio reflects elevated filling pressures and may be useful in assessing an abnormal increase in filling pressures for patients with diastolic dysfunction. The purpose of this study was to evaluate the feasibility of supine bicycle exercise Doppler echocardiography for assessing left ventricular diastolic pressure during exercise. Mitral inflow and septal mitral annulus velocities were measured at rest and during supine bicycle exercise (25-W 3-minute increments) in 45 patients (19 men; mean age, 59 years) referred for evaluation of exertional dyspnea. None had echocardiographic or electrocardiographic evidence of myocardial ischemia with exercise. Patients were classified according to E/E' ratio at rest: 26 had E/E' < or = 10 at rest (group 1) and 19 had E/E' > 10 (group 2). For group 1, 17 had no increase in E/E' during exercise (group 1A) and 9 did (group 1B). For group 2, E/E' did not increase during exercise. Despite different responses of E/E', there was no significant difference in changes of mitral inflow indices (E, A, E/A, deceleration time) between groups. Although the percentage of dyspnea as a primary reason for stopping exercise was similar for the groups, exercise duration was significantly shorter for groups 1B (7.2 +/- 2.5 minutes) and 2 (7.1 +/- 3.3 minutes) than in group 1A (10.4 +/- 3.7 minutes, P = .0129). Diastolic stress echocardiography using a supine bicycle is technically feasible for demonstrating changes in E/E' (filling pressure) with exercise. Our preliminary results suggest the hemodynamic consequences of exercise-induced increase in diastolic filling pressure can be demonstrated noninvasively with exercise Doppler echocardiography.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ommen, S. R., Nishimura, R. A., Appleton, C. P., Miller, F. A., Oh, J. K., Redfield, M. M., & Tajik, A. J. (2000) · Circulation · doi:10.1161/01.cir.102.15.1788 · Cited by 2,790
Self-citation
Cited by
Nagueh, S. F., Smiseth, O. A., Appleton, C. P., Byrd, B. F., Dokainish, H., Edvardsen, T., Flachskampf, F. A., Gillebert, T. C., Klein, A. L., Lancellotti, P., et al. (2016) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.01.011 · Cited by 5,262
Self-citationRecommendations for the Evaluation of Left Ventricular Diastolic Function by Echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelista, A. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2008.11.023 · Cited by 4,367
Self-citationRecommendations for the evaluation of left ventricular diastolic function by echocardiography
Nagueh, S. F., Appleton, C. P., Gillebert, T. C., Marino, P. N., Oh, J. K., Smiseth, O. A., Waggoner, A. D., Flachskampf, F. A., Pellikka, P. A., & Evangelisa, A. (2008) · European Journal of Echocardiography · doi:10.1093/ejechocard/jep007 · Cited by 3,351
Self-citationPellikka, P. A., Arruda-Olson, A., Chaudhry, F. A., Chen, M. H., Marshall, J. E., Porter, T. R., & Sawada, S. G. (2020) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2019.07.001 · Cited by 583
Self-citationCardiopulmonary Exercise Testing
Guazzi, M., Bandera, F., Ozemek, C., Systrom, D., & Arena, R. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.08.012 · Cited by 447
Lancellotti, P., Pellikka, P. A., Budts, W., Chaudhry, F. A., Donal, E., Dulgheru, R., Edvardsen, T., Garbi, M., Ha, J.-W., Kane, G. C., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jew190 · Cited by 438
Self-citationUnlocking the Mysteries of Diastolic Function
Lester, S. J., Tajik, A. J., Nishimura, R. A., Oh, J. K., Khandheria, B. K., & Seward, J. B. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.061 · Cited by 350
Self-citationSmiseth, O. A., Morris, D. A., Cardim, N., Cikes, M., Delgado, V., Donal, E., Flachskampf, F. A., Galderisi, M., Gerber, B. L., Gimelli, A., et al. (2022) · European Heart Journal - Cardiovascular Imaging · doi:10.1093/ehjci/jeab154 · Cited by 347
Self-citationOh, J. K., Hatle, L., Tajik, A. J., & Little, W. C. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.09.032 · Cited by 318
Self-citationLancellotti, P., Pellikka, P. A., Budts, W., Chaudhry, F. A., Donal, E., Dulgheru, R., Edvardsen, T., Garbi, M., Ha, J. W., Kane, G. C., et al. (2017) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2016.10.016 · Cited by 310
Self-citationArtificial Intelligence-Enabled ECG for Left Ventricular Diastolic Function and Filling Pressure
Lee, E., Ito, S., Miranda, W. R., Lopez-Jimenez, F., Kane, G. C., Asirvatham, S. J., Noseworthy, P. A., Friedman, P. A., Carter, R. E., Borlaug, B. A., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-023-00993-7 · Cited by 106
Self-citation
Metadata
- Authors
- Ha, J.-W., Oh, J. K., Pellikka, P. A., Ommen, S. R., Stussy, V. L., Bailey, K. R., Seward, J. B., & Tajik, A. J.
- Venue
- Journal of the American Society of Echocardiography
- Publisher
- Elsevier BV
- Published
- 2005-01
- Volume
- 18
- Issue
- 1
- Pages
- 63-68
- ISSN
- 0894-7317 (ISSN-L)
- OpenAlex
- W1984075195
- Cited by
- 294
- References
- 1
- FWCI
- 9.97
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.