The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Normal Ranges of Left Atrial Strain by Speckle-Tracking Echocardiography: A Systematic Review and Meta-Analysis
Open accessAbstract
Background: Recent advances in the assessment of myocardial function have facilitated the direct measurement of atrial function using speckle‐tracking echocardiography. Currently, normal reference ranges for atrial function using speckle‐tracking echocardiography are based on a few initial studies, with variations among modestly sized (n = 100–350) studies. Methods: The authors searched the PubMed, Embase, and Scopus databases for the key terms “left atrial/atrial/atrium” and “strain/function/deformation/stiffness” and “speckle tracking/Velocity Vector Imaging/edge tracking.” Studies of global left atrial function using speckle‐tracking were selected if they involved >30 normal or healthy participants without any cardiac risk factors. Normal ranges for reservoir strain, conduit strain, and contractile strain were computed using a random‐effects model. Meta‐regression and subgroup analysis was performed to explore between‐study heterogeneity. Results: Forty studies (2,542 healthy subjects) satisfied the inclusion criteria. Meta‐analysis revealed a normal reference range for reservoir strain of 39% (95% CI, 38%–41%, from 40 articles), for conduit strain of 23% (95% CI, 21%–25%, from 14 articles), and for contractile strain of 17% (95% CI, 16%–19%, from 18 articles). Meta‐regression identified heart rate (P = .02) and body surface area (P = .003) as contributors to this heterogeneity. Subgroup analyses revealed heterogeneity due to sample size (n > 100 vs N < 100, P = .02). Conclusions: The normal reference ranges for the three components of left atrial function are demonstrated. The between‐study heterogeneity is explained partly by heart rate, body surface area, and sample size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Measuring inconsistency in meta-analyses
Higgins, J. P. T., Thompson, S. G., Deeks, J. J., & Altman, D. G. (2003) · BMJ · doi:10.1136/bmj.327.7414.557 · Cited by 63,139
Downs, S. H., & Black, N. (1998) · Journal of Epidemiology and Community Health · doi:10.1136/jech.52.6.377 · Cited by 8,252
Greenland, S. (2001) · Biostatistics · doi:10.1093/biostatistics/2.4.463 · Cited by 359
Kishi, S., Reis, J. P., Venkatesh, B. A., Gidding, S. S., Armstrong, A. C., Jacobs, D. R., Sidney, S., Wu, C. O., Cook, N. L., Lewis, C. E., et al. (2015) · Journal of the American Heart Association · doi:10.1161/jaha.114.001264 · Cited by 96
Cited by
Left Atrial Structure and Function, and Left Ventricular Diastolic Dysfunction
Thomas, L., Marwick, T. H., Popescu, B. A., Donal, E., & Badano, L. P. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.01.059 · Cited by 653
Self-citationReddy, Y. N. V., Obokata, M., Egbe, A., Yang, J. H., Pislaru, S., Lin, G., Carter, R., & Borlaug, B. A. (2019) · European Journal of Heart Failure · doi:10.1002/ejhf.1464 · Cited by 316
Vautier, M., Mulet, B., Macquaire, C., Cousergue, C., André, C.-O., Maragnes, P., Ollitrault, P., & Labombarda, F. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1161017 · Cited by 6
Metadata
- Authors
- Pathan, F., D'Elia, N., Nolan, M. T., Marwick, T. H., & Negishi, K.
- Venue
- Journal of the American Society of Echocardiography
- Publisher
- Elsevier BV
- Published
- 2017-01
- Volume
- 30
- Issue
- 1
- Pages
- 59-70.e8
- ISSN
- 0894-7317 (ISSN-L)
- OpenAlex
- W2546224606
- Cited by
- 581
- References
- 5
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.