Comprehensive Evaluation of Tricuspid Regurgitation Location and Severity Using Vena Contracta Analysis: A Color Doppler Three-Dimensional Transesophageal Echocardiographic Study

Utsunomiya, Hiroto, Harada, Yu, Susawa, Hitoshi, Takahari, Kosuke, Ueda, Yusuke, Izumi, Kanako, Itakura, Kiho, Ikenaga, Hiroki, Hidaka, Takayuki, Fukuda, Yukihiro, Shiota, Takahiro, Kihara, Yasuki · 2019 · Journal of the American Society of Echocardiography
Cited by 50

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND The clinical significance of three-dimensional (3D) vena contracta area (VCA) in tricuspid regurgitation (TR) is not fully elucidated. The aim of this study was to investigate the diagnostic accuracy of 3D VCA using 3D echocardiography-derived regurgitation volume as a reference standard. METHODS One hundred sixteen patients with at least moderate TR underwent two-dimensional transthoracic and color Doppler 3D transesophageal echocardiography. The 3D vena contracta, which was located at the narrowest neck of the TR jet just above and toward the right atrial side of the flow convergence zone, was assessed for TR location and severity. RESULTS As for TR location, patients with severe functional TR had the highest prevalence of central jet location among TR subgroups, whereas patients with severe primary TR showed a greater spatial extent of TR jet location involved compared with the moderate TR group (P < .05 for both). As for TR severity, a 3D VCA cutoff value of 0.61 cm2 discriminated severe TR with sensitivity of 78% and specificity of 97% in the total patient population (area under the curve = 0.93, P < .001). Multivariate analysis revealed that 3D VCA, a dilated right ventricle, and hepatic vein systolic reversal were independently associated with regurgitant volume (P < .001 for all). The χ2 value for the model that incorporated clinical and two-dimensional integrative parameters and 3D VCA > 0.61 cm2 to evaluate severe TR was significantly higher than that for the model that incorporated only clinical and two-dimensional integrative parameters (P = .001). CONCLUSIONS Three-dimensional VCA has independent and incremental diagnostic value for evaluating severe TR. Comprehensive evaluation of TR location and severity using 3D vena contracta analysis may help in treatment selection for TR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.echo.2019.07.022

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 50

Metadata

Authors
Utsunomiya, H., Harada, Y., Susawa, H., Takahari, K., Ueda, Y., Izumi, K., Itakura, K., Ikenaga, H., Hidaka, T., Fukuda, Y., Shiota, T., & Kihara, Y.
Venue
Journal of the American Society of Echocardiography
Publisher
Elsevier BV
Published
2019-12
Volume
32
Issue
12
Pages
1526-1537.e2
ISSN
0894-7317 (ISSN-L)
OpenAlex
W2975614383
Cited by
50
References
1
FWCI
4.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.