The DOI matches its Crossref record.
Absorption and desorption rates of carbon dioxide with monoethanolamine and piperazine
Open accessAbstract
CO2 absorption/desorption was measured in a wetted wall column at 40 and 60 ∘C with 7, 9, 11, and 13 m monoethanolamine (MEA) and 2, 5, 8, and 12 m piperazine (PZ) at various CO2 loadings. 8 m PZ has about a 75% greater CO2 capacity than 7 m MEA. CO2 absorption and desorption is 2–3 times faster with PZ than with MEA at equivalent CO2 partial pressure. The CO2 flux normalized by the liquid side partial pressure driving force, kg, for both MEA and PZ is practically independent of temperature and amine concentration over the range of these experiments when represented as a function of the equilibrium partial pressure at 40 ∘C. Normalized flux decreases a factor of 10 as the equilibrium partial pressure at 40 ∘C increases from 100 to 10 000 Pa.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Review of CO2 Capture by Absorption and Adsorption
Yu, C.-H., Huang, C.-H., & Tan, C.-S. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.05.0132 · Cited by 1,730
Aqueous piperazine as the new standard for CO2 capture technology
Rochelle, G., Chen, E., Freeman, S., Van Wagener, D., Xu, Q., & Voice, A. (2011) · Chemical Engineering Journal · doi:10.1016/j.cej.2011.02.011 · Cited by 549
Self-citation
Metadata
- Authors
- Dugas, R., & Rochelle, G.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2009-02
- Volume
- 1
- Issue
- 1
- Pages
- 1163-1169
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W2018685935
- Cited by
- 160
- References
- 0
- FWCI
- 31.66
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Absorption and desorption rates of carbon dioxide with monoethanolamine and piperazine. https://app.cochat.ai/papers/10.1016/j.egypro.2009.01.153
- The paper
- Dugas, R., & Rochelle, G. (2009). Absorption and desorption rates of carbon dioxide with monoethanolamine and piperazine. Energy Procedia. https://doi.org/10.1016/j.egypro.2009.01.153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.