Impact of Distributed Generation on Power Distribution Systems
Open accessAbstract
In order to reduce the green house gas emissions all over the world the investment on renewable energy infrastructure is increasing particularly in the distribution network. The penetration of generating sources in the distribution network changes the characteristics of distribution system and will have impact on various technical parameters based on its size and location in the network. This paper modeled the IEEE 34 Node distribution test feeder using the commercial software package DIgSILENT power factory version 14. Solar photovoltaic generators are introduced as Distributed Generators (DGs) at various nodes and the impacts that DG produces on real and reactive power losses, voltage profile, phase imbalance and fault level of distribution system is studied. Simulated results obtained using load flow and short circuit studies are presented and discussed.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The fluctuating output patterns of single-phase DG and the irregularity of EV charging patterns aggravate voltage unbalance.
“The fluctuating characteristic output patterns of single-phase DG and the irregularity of EV charging patterns [1,2] aggravated the voltage unbalance.”
From Adaptive Volt–Var Control in Smart PV Inverter for Mitigating Voltage Unbalance at PCC Using Multiagent Deep Reinforcement Learning (2021) · cites this paper as [2]
No citation lists for this paper
No citation lists for this paper yet — checked again daily.
References 6 · Cited by 129
- Authors
- Balamurugan, K., Srinivasan, D., & Reindl, T.
- Affiliations
- National University of Singapore (SG)
- Corresponding author
- Srinivasan, Dipti
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2012
- Volume
- 25
- Pages
- 93-100
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W1989078888
- Cited by
- 129
- References
- 6
- Citations by year
- 2025: 5 · 2024: 12 · 2023: 15 · 2022: 1 · 2021: 15 · 2020: 18 · 2019: 19 · 2018: 17 · 2017: 8 · 2016: 13 · 2015: 3 · 2014: 2 · 2013: 1
- FWCI
- 2.45
- Type
- conference paper
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- Energy Procedia (publishedVersion, cc-by-nc-nd)
- National University of Singapore (submittedVersion)
- Funders
- National Research Foundation
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Keywords
- distributed generation, distribution networks, IEEE 34-node test feeder, power losses, voltage profile, phase imbalance, fault level, short-circuit analysis, power flow analysis, renewable energy integration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›