Model Predictive Control for a Smart Solar Tank Based on Weather and Consumption Forecasts
Open accessThe DOI matches its Crossref record.
Abstract
In this work the heat dynamics of a storage tank were modelled on the basis of data and maximum likelihood methods. The resulting grey-box model was used for Economic Model Predictive Control (MPC) of the energy in the tank. The control objective was to balance the energy from a solar collector and the heat consumption in a residential house. The storage tank provides heat in periods where there is low solar radiation and stores heat when there is surplus solar heat. The forecasts of consumption patterns were based on data obtained from meters in a group of single-family houses in Denmark. The tank can also be heated by electric heating elements if necessary, but the electricity costs of operating these heating elements should be minimized. Consequently, the heating elements should be used in periods with cheap electricity. It is proposed to integrate a price-sensitive control to enable the storage tank to serve a smart energy system in which flexible consumers are expected to help balance fluctuating renewable energy sources like wind and solar. Through simulations, the impact of applying Economic MPC shows annual electricity cost savings up to 25-30%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart energy and smart energy systems
Lund, H., Østergaard, P. A., Connolly, D., & Mathiesen, B. V. (2017) · Energy · doi:10.1016/j.energy.2017.05.123 · Cited by 1,157
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
“Up to date, the Illawarra Flame house [67–69] in Wollongong and 10 households in Brugg [111], the 3E Headquarters in Brussels [149] and a commercial Building in Allschwil [82,116], a building of the Czech Technical University in Prague [115,153], the UC Merced Campus [62] and the Engineers Construction Engineering Res…”
Thieblemont, H., Haghighat, F., Ooka, R., & Moreau, A. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.08.010 · Cited by 194
“…for temperature 52 % Cost (Z. Zhang, Li, Turner, & Deng, 2011) Chilled water tank Simulatio n No Not Considere d Constant charging time 2.3 % Cost (Halvgaard et al., 2012) TES Tank Simulatio n Solar Not Considere d CL 25-30% Cost (Morgan & Moncef, 2010) Ice Storage Real Building No…”
BackgroundInfluentialMPC-based optimal scheduling of grid-connected low energy buildings with thermal energy storages
Zhao, Y., Lu, Y., Yan, C., & Wang, S. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2014.10.019 · Cited by 161
Lee, D., Ooka, R., Ikeda, S., Choi, W., & Kwak, Y. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.110291 · Cited by 72
Metadata
- Authors
- Halvgaard, R., Bacher, P., Perers, B., Andersen, E., Furbo, S., Jørgensen, J. B., Poulsen, N. K., & Madsen, H.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2012
- Volume
- 30
- Pages
- 270-278
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W1976538924
- Cited by
- 62
- References
- 0
- FWCI
- 5.32
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.