The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Removal of Heavy Metals Using Nanostructured Graphite Oxide, Silica Nanoparticles and Silica/ Graphite Oxide Composite
Open accessAbstract
Heavy metals are known to be toxic for living organisms even if they are present at low levels. The presence of heavy metals and other pollutants in water continues to be a major concern and the removal of such contaminant is considered to be a major problem in environmental remediation. In the present study, nanostructured graphite oxide, silica/graphite oxide composites and silica nanoparticles were used for the removal of the heavy metal ions from aqueous solutions by a batch adsorption method and have been modelled using classical Langmuir and Freundlich adsorption isotherms. The results revealed that the adsorption of heavy metals by nanostructured graphite oxide was observed in the following order: nickel > zinc > lead > cadmium > chromium. Langmuir adsorption isotherm results showed that graphite oxide is an effective adsorbent for the removal of Nickel ions from aqueous solutions, while Freundlich data obtained for Cadmium, Chromium, Lead, Nickel and Zinc ions suggest monolayer type of adsorption by graphite oxide. Results showed that silica/graphite oxide composite (2:3) is a highly effective adsorbent material for heavy metal ions and highly recommended to be used in water purification technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Removal of heavy metal ions from wastewaters: A review
Fu, F., & Wang, Q. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2010.11.011 · Cited by 8,703 · cited 1×
“Some of these toxic elements are cadmium, lead, mercury, nickel, chromium and zinc [3].”
BackgroundLow-cost adsorbents for heavy metals uptake from contaminated water: a review
Babel, S. (2003) · Journal of Hazardous Materials · doi:10.1016/s0304-3894(02)00263-7 · Cited by 3,444
Cited by
Heavy Metal Water Pollution: A Fresh Look about Hazards, Novel and Conventional Remediation Methods
Zamora-Ledezma, C., Negrete-Bolagay, D., Figueroa, F., Zamora-Ledezma, E., Ni, M., Alexis, F., & Guerrero, V. H. (2021) · Environmental Technology & Innovation · doi:10.1016/j.eti.2021.101504 · Cited by 1,246
Wastewater Treatment and Reuse: a Review of its Applications and Health Implications
Kesari, K. K., Soni, R., Jamal, Q. M. S., Tripathi, P., Lal, J. A., Jha, N. K., Siddiqui, M. H., Kumar, P., Tripathi, V., & Ruokolainen, J. (2021) · Water, Air, & Soil Pollution · doi:10.1007/s11270-021-05154-8 · Cited by 638
Removal of heavy metals and pollutants by membrane adsorption techniques
Khulbe, K. C., & Matsuura, T. (2018) · Applied Water Science · doi:10.1007/s13201-018-0661-6 · Cited by 542
Role of nanomaterials in plants under challenging environments
Khan, M. N., Mobin, M., Abbas, Z. K., AlMutairi, K. A., & Siddiqui, Z. H. (2017) · Plant Physiology and Biochemistry · doi:10.1016/j.plaphy.2016.05.038 · Cited by 520
Effect of hexavalent chromium on the environment and removal techniques: A review
Ukhurebor, K. E., Aigbe, U. O., Onyancha, R. B., Nwankwo, W., Osibote, O. A., Paumo, H. K., Ama, O. M., Adetunji, C. O., & Siloko, I. U. (2021) · Journal of Environmental Management · doi:10.1016/j.jenvman.2020.111809 · Cited by 377
Metadata
- Authors
- Sheet, I., Kabbani, A., & Holail, H.
- Venue
- Energy Procedia
- Publisher
- Elsevier BV
- Published
- 2014
- Volume
- 50
- Pages
- 130-138
- ISSN
- 1876-6102 (ISSN-L)
- OpenAlex
- W2000387321
- Cited by
- 160
- References
- 2
- FWCI
- 55.01
- Type
- conference paper
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.