The DOI matches its Crossref record.
Comparison of biomechanical and structural properties between human aortic and pulmonary valve*1
Abstract
OBJECTIVE: Pulmonary valve autografts have been reported as clinically effective for replacement of diseased aortic valve (Ross procedure). Published data about pulmonary valve mechanical and structural suitability as a long-term substitute for aortic valve are limited. The aim of this study was to compare aortic and pulmonary valve properties. METHODS: Experimental studies of biomechanical properties and structure of aortic and pulmonary valves were carried out on pathologically unchanged human heart valves, collected from 11 cadaveric hearts. Biomechanical properties of 84 specimens (all valve elements: cusps, fibrous ring, commissures, sinotubular junction, sinuses) were investigated using uniaxial tensile tests. Ultrastructure was studied using transmission and scanning electron microscopy. RESULTS: Ultimate stress in circumferential direction for pulmonary valve cusps is higher than for aortic valve (2.78+/-1.05 and 1.74+/-0.29 MPa, respectively). Ultimate stress in radial direction for pulmonary and aortic cusps is practically the same (0.29+/-0.06 and 0.32+/-0.04 MPa, respectively). In ultrastructural study, different layout and density in each construction element are determined. The aortic and pulmonary valves have common ultrastructural properties. CONCLUSIONS: Mechanical differences between aortic and pulmonary valve are minimal. Ultrastructural studies show that the aortic and pulmonary valves have similar structural elements and architecture. This investigation suggests that the pulmonary valve can be considered mechanically and structurally suitable for use as an aortic valve replacement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vaz, C. M., van Tuijl, S., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.06.006 · Cited by 459
Heart valve function: a biomechanical perspective
Sacks, M. S., & Yoganathan, A. P. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2122 · Cited by 387
Mechanical properties of whole-body soft human tissues: a review
Singh, G., & Chanda, A. (2021) · Biomedical Materials · doi:10.1088/1748-605x/ac2b7a · Cited by 364
Biomechanical properties of native and tissue engineered heart valve constructs
Hasan, A., Ragaert, K., Swieszkowski, W., Selimović, Š., Paul, A., Camci-Unal, G., Mofrad, M. R. K., & Khademhosseini, A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.023 · Cited by 279
Heart valve macro- and microstructure
Misfeld, M., & Sievers, H.-H. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2125 · Cited by 254
Metadata
- Authors
- STRADINS, P.
- Venue
- European Journal of Cardio-Thoracic Surgery
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-09
- Volume
- 26
- Issue
- 3
- Pages
- 634-639
- ISSN
- 1010-7940 (ISSN-L)
- OpenAlex
- W1974346231
- Cited by
- 166
- References
- 0
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of biomechanical and structural properties between human aortic and pulmonary valve*1. https://app.cochat.ai/papers/10.1016/j.ejcts.2004.05.043
- The paper
- STRADINS, P. (2004). Comparison of biomechanical and structural properties between human aortic and pulmonary valve*1. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1016/j.ejcts.2004.05.043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.