Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record.

Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆

Open access
WALTHER, T, RASTAN, A, FALK, V, LEHMANN, S, GARBADE, J, FUNKAT, A, MOHR, F, GUMMERT, J·2006·European Journal of Cardio-Thoracic Surgery

Abstract

Aortic valve replacement (AVR) has evolved as a standard procedure with low morbidity and mortality over the past decades [1]. AVR is performed in more than 10,000 patients annually in Germany. In-hospital mortality was 2.5% after mechanical valve and 3.8% after xenograft implantation in 2004 [2]. In the US the risk for isolated AVR was 4.3% in 1999 [3]. Age has been identified as an independent risk factor and subgroups, especially octogenarians have a higher risk of up to 10% following aortic valve surgery [3,4]. For AVR conventional stented xenografts or mechanical prostheses are most frequently implanted. No perfect artificial prosthesis is available at present. Conventional stents lead to some obstruction of blood flow. Stent design has evolved during the past years towards lower profiles and thinner sewing rings. Thus adequate effective orifice areas and sufficient hemodynamic function can be obtained for most patients. Residual obstruction usually is well compensated by the – frequently hypertrophied – left ventricle. However, obstruction to blood flow may also be related to an increase in perioperative and postoperative morbidity and mortality. The concept of patient prosthesis mismatch (PPM) had been introduced by Rahimtoola [5] in the 1970s. More recently there were publications by groups in favor of the hypothesis that PPM is an independent predictor of mortality [6,7]. In contradiction there are others that found that survival after AVR appears not to be adversely affected by moderate PPM [8]. Aim of our study was to evaluate the incidence of PPM as well as its potential impact on adverse patient outcome. In addition, we thought to assess the clinical relevance of additional risk factors after AVR. A total of 4131 patients operated during an eight-year period between May 1996 and April 2004 were evaluated. All patients were prospectively included into the hospital's patient data management system. Based on these data entered during routine clinical therapy further analyses were performed. All patients having elective or emergency AVR during this time period were included. Patients receiving stentless AVR were excluded from this analysis. A total of 1856 patients received bileaflet mechanical AVR and 2275 patients received conventional stented xenograft AVR. The possible impact of PPM on survival and perioperative outcome was evaluated. By intention additional analysis on the incidence of PPM in relation to the different valve prostheses was not performed as multiple criteria for individual valve selection exist. PPM was defined in three categories according to standard definitions as published by the Quebec group [6]. The aortic valve prosthesis effective valve orifice area (EOA) was divided by body surface area (BSA) to obtain the EOA index. PPM was then defined as none if EOA index was >0.85 cm2/m2, as moderate for 0.65–0.85 cm2/m2 and as severe for <0.65 cm2/m2. Effective valve orifice areas were derived from the literature as provided by the manufacturers and from scientific publications from in vitro measurements [6,9]. Values of expected effective orifice areas from in vitro measurements for the different aortic valve prostheses implanted that were used in this study are given in Table 1. Values of expected effective orifice areas (EOA) for the different aortic valve prostheses implanted used in this study Individual patient contact was achieved by sending questionnaires to all patients annually after the operation. Non-responders were contacted by telephone; if no further information was available the family physicians were contacted. Follow-up results were available for all 4131 patients evaluated. Follow-up extended to 8.5 years at a mean of 5.2 ± 3.5 years. Results are given in a standard fashion with continuous variables expressed as mean ± standard deviation and categorical data as proportions. For continuous variables comparisons were performed using Student's t-test (variables with normal distribution) or the Mann–Whitney U-test. Categorical variables were compared by chi-square analysis. Univariate analysis of risk factors was performed calculating odds ratios (OR) with 95% confidence intervals. Several factors, patient age, gender, body weight, body surface area, diameter of the aortic valve prosthesis in millimeter, presence or absence of PPM, emergency indication, the EuroSCORE [10] value indicating the specific risk for the individual patient and requirement for additional surgery (e.g., AVR + coronary artery bypass graft (CABG) surgery or AVR + other valve ± aortic surgery) were tested. Variables with a p-value less than 0.05 were consecutively subjected to a multivariate logistic regression model to assess the independent impact of the risk factors on outcome. A stepwise procedure (backward Wald) was used. A p-value less than 0.05 was used both to enter and eliminate variables. Cumulative survival was calculated by Kaplan–Meier methods and differences in follow-up were calcu

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ejcts.2006.04.007

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 186

Metadata

Authors
WALTHER, T., RASTAN, A., FALK, V, LEHMANN, S., GARBADE, J., FUNKAT, A., MOHR, F., & GUMMERT, J.
Venue
European Journal of Cardio-Thoracic Surgery
Published
2006-07
Volume
30
Issue
1
Pages
15-19
ISSN
1010-7940 (ISSN-L)
OpenAlex
W2129744994
Cited by
186
References
0
FWCI
11.37
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆. https://app.cochat.ai/papers/10.1016/j.ejcts.2006.04.007
The paper
WALTHER, T., RASTAN, A., FALK, V, LEHMANN, S., GARBADE, J., FUNKAT, A., MOHR, F., & GUMMERT, J. (2006). Patient prosthesis mismatch affects short- and long-term outcomes after aortic valve replacement☆. European Journal of Cardio-Thoracic Surgery. https://doi.org/10.1016/j.ejcts.2006.04.007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.