Alveolar-Capillary Membrane Conductance is the Best Pulmonary Function Correlate of Exercise Ventilation Efficiency in Heart Failure Patients
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: In heart failure (HF), changes in lung mechanics and gas diffusion are limiting factors to exercise. Their contribution to an increased exercise ventilation to CO2 production (VE/VCO2) slope is undefined. Methods: A total of 67 stable HF patients underwent cardiopulmonary exercise and pulmonary function tests, including forced vital capacity (FVC), forced expiratory volume in 1 s (FEV1), maximal voluntary ventilation (MVV), total lung capacity (TLC) and alveolar diffusing capacity with its subcomponents (alveolar-capillary membrane conductance (Dm) and capillary blood volume (Vc)). Results: Patients showed a mild restrictive pattern (FEV1=85±15% and FVC=75±13% of normal predicted) and a moderate Dm reduction (32±12 ml min−1 mm Hg−1). Average peak VO2 was 15.6±4.0 ml min−1 kg−1 and the VE/VCO2 slope was 39.6±11.0. At simple Spearman correlation analysis, all variables, but Vc, correlated with peak VO2; only Dm correlated with VE/VCO2 slope. At partial Spearman correlation, all variables lost the peak VO2 correlation, and Dm still inversely correlated with VE/VCO2 slope (r=−0.35; p=0.005). In patients with a high VE/VCO2 slope (cutoff value 34), despite comparable lung volumes, Dm was significantly more depressed (30±13 vs. 35±10 ml min−1 mm Hg−1; p<0.01). Conclusions: Pulmonary function tests and alveolar gas diffusing capacity poorly correlate with peak VO2. Dm impairment rather than lung volumes correlates with exercise ventilation efficiency. This finding further adds to the pathophysiological relevance of an abnormal gas exchange in HF patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Cited by
Arena, R., Myers, J., & Guazzi, M. (2008) · Heart Failure Reviews · doi:10.1007/s10741-007-9067-5 · Cited by 268
Self-citationGiardini, A., Specchia, S., Tacy, T. A., Coutsoumbas, G., Gargiulo, G., Donti, A., Formigari, R., Bonvicini, M., & Picchio, F. M. (2007) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.12.076 · Cited by 160
Metadata
- Authors
- Guazzi, M., Reina, G., Tumminello, G., & Guazzi, M. D.
- Venue
- European Journal of Heart Failure
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-10-01
- Volume
- 7
- Issue
- 6
- Pages
- 1017-1022
- ISSN
- 1388-9842 (ISSN-L)
- 1879-0844
- OpenAlex
- W1983624318
- Cited by
- 40
- References
- 1
- FWCI
- 9.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Alveolar-Capillary Membrane Conductance is the Best Pulmonary Function Correlate of Exercise Ventilation Efficiency in Heart Failure Patients. https://app.cochat.ai/papers/10.1016/j.ejheart.2004.10.009
- The paper
- Guazzi, M., Reina, G., Tumminello, G., & Guazzi, M. D. (2005). Alveolar-Capillary Membrane Conductance is the Best Pulmonary Function Correlate of Exercise Ventilation Efficiency in Heart Failure Patients. European Journal of Heart Failure. https://doi.org/10.1016/j.ejheart.2004.10.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.