CoChat

Evaluation of radiomic texture feature error due to MRI acquisition and reconstruction: A simulation study utilizing ground truth

Yang, Fei, Dogan, Nesrin, Stoyanova, Radka, Ford, John Chetley · 2018 · Physica Medica
Cited by 112

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

The purpose of this study was to examine the dependence of image texture features on MR acquisition parameters and reconstruction using a digital MR imaging phantom. MR signal was simulated in a parallel imaging radiofrequency coil setting as well as a single element volume coil setting, with varying levels of acquisition noise, three acceleration factors, and four image reconstruction algorithms. Twenty-six texture features were measured on the simulated images, ground truth images, and clinical brain images. Subtle algorithm-dependent errors were observed on reconstructed phantom images, even in the absence of added noise. Sources of image error include Gibbs ringing at image edge gradients (tissue interfaces) and well-known artifacts due to high acceleration; two of the iterative reconstruction algorithms studied were able to mitigate these image errors. The difference of the texture features from ground truth, and their variance over reconstruction algorithm and parallel imaging acceleration factor, were compared to the clinical "effect size", i.e., the feature difference between high- and low-grade tumors on T1- and T2-weighted brain MR images of twenty glioma patients. The measured feature error (difference from ground truth) was small for some features, but substantial for others. The feature variance due to reconstruction algorithm and acceleration factor were generally smaller than the clinical effect size. Certain texture features may be preserved by MR imaging, but adequate precautions need to be taken regarding their validity and reliability. We present a general simulation framework for assessing the robustness and accuracy of radiomic textural features under various MR acquisition/reconstruction scenarios.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ejmp.2018.05.017

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 112

Metadata

Authors
Yang, F., Dogan, N., Stoyanova, R., & Ford, J. C.
Venue
Physica Medica
Publisher
Elsevier BV
Published
2018-06
Volume
50
Pages
26-36
ISSN
1120-1797 (ISSN-L)
OpenAlex
W2804243838
Cited by
112
References
6
FWCI
9.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of radiomic texture feature error due to MRI acquisition and reconstruction: A simulation study utilizing ground truth. https://app.cochat.ai/papers/10.1016/j.ejmp.2018.05.017
The paper
Yang, F., Dogan, N., Stoyanova, R., & Ford, J. C. (2018). Evaluation of radiomic texture feature error due to MRI acquisition and reconstruction: A simulation study utilizing ground truth. Physica Medica. https://doi.org/10.1016/j.ejmp.2018.05.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.