CoChat

The EU medical device regulation: Implications for artificial intelligence-based medical device software in medical physics

Open access
Beckers, R., Kwade, Z., Zanca, F. · 2021 · Physica Medica
Cited by 139

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Medical device manufacturers are increasingly applying artificial intelligence (AI) to innovate their products and to improve patient outcomes. Health institutions are also developing their own algorithms, to address specific needs for which no commercial product exists. Although AI-based algorithms offer good prospects for improving patient outcomes, their wide adoption in clinical practice is still limited. The most significant barriers to the trust required for wider implementation are safety and clinical performance assurance . Qualified medical physicist experts (MPEs) play a key role in safety and performance assessment of such tools, before and during integration in clinical practice. As AI methods drive clinical decision-making, their quality should be assured and tested. Occasionally, an MPE may be also involved in the in-house development of such an AI algorithm. It is therefore important for MPEs to be well informed about the current regulatory framework for Medical Devices. The new European Medical Device Regulation (EU MDR), with date of application set for 26 of May 2021, imposes stringent requirements that need to be met before such tools can be applied in clinical practice. The objective of this paper is to give MPEs perspective on how the EU MDR affects the development of AI-based medical device software. We present our perspective regarding how to implement a regulatory roadmap, from early-stage consideration through design and development, regulatory submission, and post-market surveillance. We have further included an explanation of how to set up a compliant quality management system to ensure reliable and consistent product quality, safety, and performance .

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.ejmp.2021.02.011

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 139

Metadata

Authors
Beckers, R., Kwade, Z., & Zanca, F.
Venue
Physica Medica
Publisher
Elsevier BV
Published
2021-03
Volume
83
Pages
1-8
ISSN
1120-1797 (ISSN-L)
OpenAlex
W3135016904
Cited by
139
References
5
FWCI
15.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The EU medical device regulation: Implications for artificial intelligence-based medical device software in medical physics. https://app.cochat.ai/papers/10.1016/j.ejmp.2021.02.011
The paper
Beckers, R., Kwade, Z., & Zanca, F. (2021). The EU medical device regulation: Implications for artificial intelligence-based medical device software in medical physics. Physica Medica. https://doi.org/10.1016/j.ejmp.2021.02.011

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.