Observer variability of Breast Imaging Reporting and Data System (BI-RADS) for breast ultrasound
Open accessThe DOI matches its Crossref record.
Abstract
PURPOSE To evaluate inter- and intra-observer variabilities in breast sonographic feature analysis and management, using the fourth edition of the Breast Imaging Reporting and Data System (BI-RADS). MATERIALS AND METHODS We included 136 patients with 150 breast lesions who underwent breast ultrasound (US) and ultrasound-guided core needle biopsy. A pathological diagnosis was available for all 150 lesions: 77 (51%) malignant and 73 (49%) benign. Four radiologists retrospectively reviewed sonographic images of lesions twice within an 8-week interval. The observers described each lesion, using BI-RADS descriptors and final assessment. Inter- and intra-observer variabilities were assessed with Cohen's kappa statistic. Positive predictive value and negative predictive value (NPV) for final assessment were also calculated. RESULTS For inter-observer agreements for sonographic descriptors, substantial agreement for lesion calcification and final assessment (kappa=0.61 for both), moderate agreement for lesion shape, orientation, boundary, and posterior acoustic features (kappa=0.49, 0.56, 0.59, and 0.49, respectively), and fair agreement for lesion margin and echo pattern (kappa=0.33 and 0.37, respectively) were obtained. For intra-observer agreement, substantial to perfect agreement was found for almost all lesion descriptors and final assessments. NPV for final assessment category 3 was 95%. Positive predictive value (PPV) for final assessment categorized as 4 or 5 were as follows: category 4a, 26%; category 4b, 89%; category 4c, 90%; and category 5, 97%. CONCLUSION Because inter- and intra-observer agreement with the BI-RADS lexicon for US is good, the use of BI-RADS lexicon can provide accurate and consistent description and assessment for breast US.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review
Guo, R., Lu, G., Qin, B., & Fei, B. (2018) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2017.09.012 · Cited by 542
Shear wave elastography for breast masses is highly reproducible
the BE1 Study Group, Cosgrove, D. O., Berg, W. A., Doré, C. J., Skyba, D. M., Henry, J.-P., Gay, J., & Cohen-Bacrie, C. (2012) · European Radiology · doi:10.1007/s00330-011-2340-y · Cited by 406
Qian, X., Pei, J., Zheng, H., Xie, X., Yan, L., Zhang, H., Han, C., Gao, X., Zhang, H., Zheng, W., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00711-2 · Cited by 253
Ciritsis, A., Rossi, C., Eberhard, M., Marcon, M., Becker, A. S., & Boss, A. (2019) · European Radiology · doi:10.1007/s00330-019-06118-7 · Cited by 117
Metadata
- Authors
- Lee, H.-J., Kim, E.-K., Kim, M. J., Youk, J. H., Lee, J. Y., Kang, D. R., & Oh, K. K.
- Venue
- European Journal of Radiology
- Publisher
- Elsevier BV
- Published
- 2008-02
- Volume
- 65
- Issue
- 2
- Pages
- 293-298
- ISSN
- 0720-048X (ISSN-L)
- OpenAlex
- W2109305028
- Cited by
- 181
- References
- 0
- FWCI
- 3.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.