Cited by 62Medical Imaging Techniques and ApplicationsCardiac Imaging and DiagnosticsRadiation Dose and Imaging

Clinical evaluation of PET image reconstruction using a spatial resolution model

Andersen, Flemming Littrup, Klausen, Thomas Levin, Loft, Annika, Beyer, Thomas, Holm, Søren·2013·European Journal of Radiology

Abstract

Purpose PET image resolution is variable across the measured field-of-view and described by the point spread function (PSF). When accounting for the PSF during PET image reconstruction image resolution is improved and partial volume effects are reduced. Here, we evaluate the effect of PSF-based reconstruction on lesion quantification in routine clinical whole-body (WB) PET/CT imaging. Materials and methods 41 oncology patients were referred for a WB-PET/CT examination (Biograph 40 TruePoint). Emission data were acquired at 2.5 min/bed at 1 hpi of 400 MBq [18F]-FDG. Attenuation-corrected PET images were reconstructed on 336 × 336-matrices using: (R1) standard AW-OSEM (4 iter, 8 subsets, 4 mm Gaussian) and (R2) AW-OSEM with PSF (3 iter, 21 subsets, 2 mm). Blinded and randomised reading of R1- and R2-PET images was performed. Individual lesions were located and counted independently on both sets of images. The relative change in PET quantification (SUVmax, SUVmean, volume) of lesions seen on R1 and R2 is reported as (R2-R1)/R1. Furthermore, SUVmax and SUVmean was measured for a 3 cm spherical norm region in the right lobe of the healthy liver for R1 and R2. Results Clinical reading revealed 91 and 103 positive lesions for R1 and R2, respectively. For all lesions SUVmax (R2) was higher than SUVmax (R1). Regression analysis indicated that the relative increase in SUVmax (and SUVmean) decreased with lesion size, whilst it increased with increasing radial distance from the centre of…

Integrity signals

Registry

Crossref · 10.1016/j.ejrad.2012.11.015

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Discrepancies about PSF may stem from the ability of PSF to increase lesion contrast recovery being most prominent at the periphery of the transaxial FOV and in small, high-contrast lesions such as pulmonary nodules.

    “These discrepancies may stem from the fact that the ability of PSF to increase lesion CR is most prominent at the periphery of the transaxial FOV [98,166,167] and in small, high-contrast lesions [95], such as pulmonary nodules.”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [166]

No citation lists for this paper

No citation lists for this paper yet — checked again daily.

References 31 · Cited by 62

Authors
Andersen, F. L., Klausen, T. L., Loft, A., Beyer, T., & Holm, S.
Affiliations
Copenhagen University Hospital (DK)
Corresponding author
Holm, Søren
Venue
European Journal of Radiology
Publisher
Elsevier BV
Published
2013-05
Volume
82
Issue
5
Pages
862-869
ISSN
0720-048X (ISSN-L)
OpenAlex
W2049231321
Cited by
62
References
31
Citations by year
2024: 3 · 2023: 2 · 2022: 2 · 2021: 9 · 2020: 4 · 2019: 6 · 2018: 8 · 2017: 9 · 2016: 2 · 2015: 6 · 2014: 8 · 2013: 3
FWCI
4.11
Type
journal article
Language
en
Open access
closed
Locations
  • European Journal of Radiology (publishedVersion)
  • PubMed (publishedVersion)
Funders
John and Birthe Meyer Foundation
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
Keywords
PET image reconstruction, point spread function, whole-body PET/CT, FDG-PET, lesion quantification, SUVmax, SUVmean, lesion detection, partial volume effect, attenuation correction, OSEM reconstruction, field of view
MeSH terms
Adolescent, Adult, Aged, Aged, 80 and over, Algorithms, Computer Simulation, Female, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Male, Middle Aged, Models, Biological, Neoplasms, Sensitivity and Specificity, Reproducibility of Results, Radiopharmaceuticals, Fluorodeoxyglucose F18, Imaging, Three-Dimensional, Positron-Emission Tomography, Whole Body Imaging, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review