The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Batch mode and continuous desalination of water using flowing carbon deionization (FCDI) technology
Abstract
Abstract We report batch and continuous electrochemical desalination utilizing the ion adsorption capacity of a slurry containing carbon particles. Two carbon suspensions and the feed water are fed into the electrochemical cell operated according to the principle of membrane assisted capacitive deionization (MCDI). In a batch mode operation after the desalination step is complete the adsorbed ions are discharged from flowing electrodes to the same portion of water using polarity reversal. Operation with 15 g NaCl/l water solution resulted in extremely high apparent salt adsorption capacity (SAC) value of 260 mg/g dry carbon . This value is much higher than the highest value of SAC reported until now — 14.3 mg/g. The reason for this phenomenon is not clear and further research is currently performed. In a new truly continuous process, both slurry streams are continuously recirculated between the desalination module and a regeneration/concentration module operated with the same functionality but with reversed potential. Ions desorb from the flowing electrodes and concentrate through the membranes into a purge stream. We prove continuous operation with desalination rate of more than 99% for an initial salt concentration of 1 g NaCl/l. Concentration factors depend on the recovery, with 90% water recovery being demonstrated easily.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, M. A., Cudero, A. L., & Palma, J. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.02.012 · Cited by 943
Desalination via a New Membrane Capacitive Deionization Process Utilizing Flow-Electrodes
Jeon, S.-I., Park, H.-R., Yeo, J.-G., Yang, S., Cho, C. H., Han, M. H., & Kim, D. K. (2013) · Energy & Environmental Science · doi:10.1039/c3ee24443a · Cited by 727
Cited by
Srimuk, P., Su, X., Yoon, J., Aurbach, D., & Presser, V. (2020) · Nature Reviews Materials · doi:10.1038/s41578-020-0193-1 · Cited by 665
Electrochemical Methods for Water Purification, Ion Separations, and Energy Conversion
Alkhadra, M. A., Su, X., Suss, M. E., Tian, H., Guyes, E. N., Shocron, A. N., Conforti, K. M., de Souza, J. P., Kim, N., Tedesco, M., et al. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00396 · Cited by 661
Various cell architectures of capacitive deionization: Recent advances and future trends
Tang, W., Liang, J., He, D., Gong, J., Tang, L., Liu, Z., Wang, D., & Zeng, G. (2019) · Water Research · doi:10.1016/j.watres.2018.11.064 · Cited by 461
Gao, X., Omosebi, A., Landon, J., & Liu, K. (2015) · Energy & Environmental Science · doi:10.1039/c4ee03172e · Cited by 412
Carbon electrodes for capacitive deionization
Huang, Z.-H., Yang, Z., Kang, F., & Inagaki, M. (2017) · Journal of Materials Chemistry A · doi:10.1039/c6ta06733f · Cited by 372
Metadata
- Authors
- Gendel, Y., Rommerskirchen, A. K. E., David, O., & Wessling, M.
- Venue
- Electrochemistry Communications
- Publisher
- Elsevier BV
- Published
- 2014-09
- Volume
- 46
- Pages
- 152-156
- ISSN
- 1388-2481 (ISSN-L)
- OpenAlex
- W2004720493
- Cited by
- 180
- References
- 2
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.