The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Improved electrochemical detection of metals in biological samples using 3D-printed electrode: Chemical/electrochemical treatment exposes carbon-black conductive sites
Abstract
This work shows that the electrochemical activity of a 3D-printed electrode fabricated using a conductive composite of polylactic acid (PLA) containing carbon black (CB) can be substantially improved through a simple and fast chemical/electrochemical pretreatment in 0.5 mol L−1 NaOH. Scanning electron microscopy and infrared spectroscopy data showed that the pretreatment process promotes the removal of the non-conductive PLA material, providing greater exposure of the conductive particles. Cyclic voltammetry of the redox probe ferricyanide/ferrocyanide indicated faster electron transfer on the treated 3D-printed surface and increase in electroactive area. Moreover, electrochemical impedance spectroscopic results also confirmed faster electron transfer after surface pretreatment. As a proof-of-concept, a low-cost and sensitive method for the determination of cadmium and lead in real urine and saliva samples by square-wave anodic stripping voltammetry was developed. The chemical/electrochemical treatment provided an impressive 30-fold current increase in the detection of both metals. Acceptable limits of detection (2.9 μg L−1 for Cd2+ and 2.6 μg L−1 for Pb2+), wide linear ranges for both metals (30 μg L−1 to 270 μg L−1; R = 0.997), high stability (RSD lower than 4.5%; n = 10), and adequate recovery values (between 93% and 112%) for the analysis of spiked samples were achieved. Additionally, interday (n = 3), intra-day (n = 3), inter-electrode (n = 2) and inter-treatment (n = 2) experiments revealed RSD values lower than 6.5%, which indicates high reproducibility of the proposed treated 3D-printed electrode. The strategy here proposed opens up new applications for 3D-printed electrode in analytical electrochemistry with improved electrochemical sensing properties in comparison to screen-printed electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recent Advances in Analytical Chemistry by 3D Printing
Gross, B., Lockwood, S. Y., & Spence, D. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04344 · Cited by 359
3D-printed flow system for determination of lead in natural waters
Mattio, E., Robert-Peillard, F., Branger, C., Puzio, K., Margaillan, A., Brach-Papa, C., Knoery, J., Boudenne, J.-L., & Coulomb, B. (2017) · Talanta · doi:10.1016/j.talanta.2017.03.059 · Cited by 55
Cited by
Additive-manufactured (3D-printed) electrochemical sensors: A critical review
Cardoso, R. M., Kalinke, C., Rocha, R. G., dos Santos, P. L., Rocha, D. P., Oliveira, P. R., Janegitz, B. C., Bonacin, J. A., Richter, E. M., & Munoz, R. A. A. (2020) · Analytica Chimica Acta · doi:10.1016/j.aca.2020.03.028 · Cited by 460
Self-citation
Metadata
- Authors
- Rocha, D. P., Squissato, A. L., da Silva, S. M., Richter, E. M., & Munoz, R. A. A.
- Venue
- Electrochimica Acta
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 335
- Pages
- 135688
- ISSN
- 0013-4686 (ISSN-L)
- OpenAlex
- W3000676978
- Cited by
- 174
- References
- 2
- FWCI
- 10.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.