Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 174

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Improved electrochemical detection of metals in biological samples using 3D-printed electrode: Chemical/electrochemical treatment exposes carbon-black conductive sites

Rocha, Diego P., Squissato, André L., da Silva, Sarah M., Richter, Eduardo M., Munoz, Rodrigo A.A. · 2020 · Electrochimica Acta

Abstract

This work shows that the electrochemical activity of a 3D-printed electrode fabricated using a conductive composite of polylactic acid (PLA) containing carbon black (CB) can be substantially improved through a simple and fast chemical/electrochemical pretreatment in 0.5 mol L−1 NaOH. Scanning electron microscopy and infrared spectroscopy data showed that the pretreatment process promotes the removal of the non-conductive PLA material, providing greater exposure of the conductive particles. Cyclic voltammetry of the redox probe ferricyanide/ferrocyanide indicated faster electron transfer on the treated 3D-printed surface and increase in electroactive area. Moreover, electrochemical impedance spectroscopic results also confirmed faster electron transfer after surface pretreatment. As a proof-of-concept, a low-cost and sensitive method for the determination of cadmium and lead in real urine and saliva samples by square-wave anodic stripping voltammetry was developed. The chemical/electrochemical treatment provided an impressive 30-fold current increase in the detection of both metals. Acceptable limits of detection (2.9 μg L−1 for Cd2+ and 2.6 μg L−1 for Pb2+), wide linear ranges for both metals (30 μg L−1 to 270 μg L−1; R = 0.997), high stability (RSD lower than 4.5%; n = 10), and adequate recovery values (between 93% and 112%) for the analysis of spiked samples were achieved. Additionally, interday (n = 3), intra-day (n = 3), inter-electrode (n = 2) and inter-treatment (n = 2) experiments revealed RSD values lower than 6.5%, which indicates high reproducibility of the proposed treated 3D-printed electrode. The strategy here proposed opens up new applications for 3D-printed electrode in analytical electrochemistry with improved electrochemical sensing properties in comparison to screen-printed electrodes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.electacta.2020.135688

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 174

Metadata

Authors
Rocha, D. P., Squissato, A. L., da Silva, S. M., Richter, E. M., & Munoz, R. A. A.
Venue
Electrochimica Acta
Publisher
Elsevier BV
Published
2020-03
Volume
335
Pages
135688
ISSN
0013-4686 (ISSN-L)
OpenAlex
W3000676978
Cited by
174
References
2
FWCI
10.36
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.