The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Building temperature regulation using a distributed model predictive control
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lee, J. H., Kaisare, N. S., & García, C. E. (2007) · Springer eBooks · doi:10.1002/9781394333325.fmatter · Cited by 3,766
Model predictive control: past, present and future
Morari, M., & H. Lee, J. (1999) · Computers & Chemical Engineering · doi:10.1016/s0098-1354(98)00301-9 · Cited by 2,335
Corriou, J.-P. (2004) · Process Control · doi:10.1007/978-1-4471-3848-8_16 · Cited by 1,271
Distributed model predictive control
(2002) · IEEE Control Systems · doi:10.1109/37.980246 · Cited by 957
Predictive controllers for thermal comfort optimization and energy savings
Freire, R. Z., Oliveira, G. H. C., & Mendes, N. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.12.007 · Cited by 362
Design and simulation of self-tuning PID-type fuzzy adaptive control for an expert HVAC system
Soygüder, S., Karaköse, M., & Alli, H. (2008) · Expert Systems with Applications · doi:10.1016/j.eswa.2008.05.031 · Cited by 230
The control of indoor thermal comfort conditions: introducing a fuzzy adaptive controller
Calvino, F., Gennusa, M. L., Rizzo, G., et al. (2003) · Energy and Buildings · doi:10.1016/j.enbuild.2003.10.004 · Cited by 193
LI, S., ZHANG, Y., & ZHU, Q. (2005) · Information Sciences · doi:10.1016/j.ins.2004.03.008 · Cited by 176
Advanced controller auto-tuning and its application in HVAC systems
Bi, Q., Cai, W., Wang, Q., Hang, C.-C., Lee, E.-L., Sun, Y. H., Liu, K.-D., Zhang, Y. A., & Zou, B. (2000) · Control Engineering Practice · doi:10.1016/s0967-0661(99)00198-7 · Cited by 144
Zhang, Y., & Li, S. (2006) · Journal of Process Control · doi:10.1016/j.jprocont.2006.08.009 · Cited by 123
Cited by
Theory and applications of HVAC control systems – A review of model predictive control (MPC)
Afram, A., & Janabi-Sharifi, F. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.11.016 · Cited by 1,310
All you need to know about model predictive control for buildings
Drgoňa, J., Arroyo, J., Cupeiro Figueroa, I., Blum, D., Arendt, K., Kim, D., Ollé, E. P., Oravec, J., Wetter, M., Vrabie, D. L., et al. (2020) · Annual Reviews in Control · doi:10.1016/j.arcontrol.2020.09.001 · Cited by 1,020
Shaikh, P. H., Nor, N. B. M., Nallagownden, P., Elamvazuthi, I., & Ibrahim, T. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.027 · Cited by 866
Serale, G., Fiorentini, M., Capozzoli, A., Bernardini, D., & Bemporad, A. (2018) · Energies · doi:10.3390/en11030631 · Cited by 637
Review of building energy modeling for control and operation
Li, X., & Wen, J. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.05.056 · Cited by 629
Metadata
- Authors
- Moroşan, P.-D., Bourdais, R., Dumur, D., & Buisson, J.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2010-09
- Volume
- 42
- Issue
- 9
- Pages
- 1445-1452
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W1970181869
- Cited by
- 365
- References
- 12
- FWCI
- 41.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Building temperature regulation using a distributed model predictive control. https://app.cochat.ai/papers/10.1016/j.enbuild.2010.03.014
- The paper
- Moroşan, P.-D., Bourdais, R., Dumur, D., & Buisson, J. (2010). Building temperature regulation using a distributed model predictive control. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2010.03.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.