Review of thermal energy storage technologies based on PCM application in buildings
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
TES systems also increase the cooling system reliability and can easily be integrated with other functions such as on-site fire protection water storages.
“TES systems also increase the cooling system reliability and can easily be integrated with other functions such as on-site fire protection water storages [163].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [163]
TES systems operate as a cost-saving measure by shifting the energy demand to low-tariff periods.
“TES systems operate as a cost-saving measure by shifting the energy demand to low-tariff periods [162].”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [162]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 74
- Hong, 2000, Preparation of polyethylene-paraffin compound as a form-stable solid–liquid phase change material, Solar Energy Materials and Solar Cells, 64, 37, 10.1016/S0927-0248(00)00041-6 · DOI
- Cho, 2002, Microencapsulation of octadecane as a phase-change material by interfacial polymerization in an emulsion system, Colloid and Polymer Science, 280, 260, 10.1007/s00396-001-0603-x · DOI
- Liang, 2009, Microencapsulation of butyl stearate as phase change material by interfacial polycondensation in a polyurea system, Energy Conservation and Management, 50, 723, 10.1016/j.enconman.2008.09.044 · DOI
- Abhat, 1983, Low temperature latent heat thermal energy storage: heat storage materials, Solar Energy, 30, 313, 10.1016/0038-092X(83)90186-X · DOI
- Zalba, 2003, Review on thermal energy storage with phase change: materials, heat transfer analysis and applications, Applied Thermal Engineering, 23, 251, 10.1016/S1359-4311(02)00192-8 · DOI
- Khudhair, 2004, A review on energy conservation in building applications with thermal storage by latent heat using phase change materials, Energy Conservation and Management, 45, 263, 10.1016/S0196-8904(03)00131-6 · DOI
- Zhang, 2007, Application of latent heat thermal energy storage in buildings: State-of-the-art and outlook, Building and Environment, 42, 2197, 10.1016/j.buildenv.2006.07.023 · DOI
- Günther, 2009, Enthalpy of phase change materials as a function of temperature: required accuracy and suitable measurement methods, International Journal of Thermophysics, 30, 1257, 10.1007/s10765-009-0641-z · DOI
- Zhang, 1999, A simple method, the T-history method, of determining the heat of fusion, specific heat and thermal conductivity of phase change materials, Measurement Science and Technology, 10, 201, 10.1088/0957-0233/10/3/015 · DOI
- Zhang, 2006, Influence of additives on thermal conductivity of shape- stabilized phase change material, Solar Energy Materials and Solar Cells, 90, 1692, 10.1016/j.solmat.2005.09.007 · DOI
- Esen, 1998, Geometric design of solar-aided latent heat storage depending on various parameters and phase change materials, Solar Energy, 62, 19, 10.1016/S0038-092X(97)00104-7 · DOI
- Kousksou, 2011, PCM storage for solar DHW: from an unfulfilled promise to a real benefit, Solar Energy, 85, 2033, 10.1016/j.solener.2011.05.012 · DOI
- Regin, 2008, Heat transfer characteristics of thermal energy storage system using PCM capsules: a review, Renewable and Sustainable Energy Reviews, 12, 2438, 10.1016/j.rser.2007.06.009 · DOI
- Zhu, 2009, Dynamic characteristics and energy performance of buildings using phase change materials: a review, Energy Conservation and Management, 50, 3169, 10.1016/j.enconman.2009.08.019 · DOI
- Cabeza, 2011, Materials used as PCM in thermal energy storage in buildings: a review, Renewable and Sustainable Energy Reviews, 15, 1675, 10.1016/j.rser.2010.11.018 · DOI
- Delgado, 2012, Review on phase change material emulsions and microencapsulated phase change material slurries: materials, heat transfer studies and applications, Renewable and Sustainable Energy Reviews, 16, 253, 10.1016/j.rser.2011.07.152 · DOI
- Osterman, 2012, Review of PCM based cooling technologies for buildings, Energy and Buildings, 49, 37, 10.1016/j.enbuild.2012.03.022 · DOI
- Voelker, 2008, Temperature reduction due to the application of phase change materials, Energy and Buildings, 40, 937, 10.1016/j.enbuild.2007.07.008 · DOI
- Schossig, 2005, Micro-encapsulated phase-change materials integrated into construction materials, Solar Energy Materials and Solar Cells, 89, 297, 10.1016/j.solmat.2005.01.017 · DOI
- Kuznik, 2009, Experimental assessment of phase change material for wall building use, Applied Energy, 86, 2038, 10.1016/j.apenergy.2009.01.004 · DOI
- Kuznik, 2009, Experimental investigation of wallboard containing phase change material: data for validation of numerical modeling, Energy and Buildings, 41, 561, 10.1016/j.enbuild.2008.11.022 · DOI
- Oliver, 2012, Thermal characterization of gypsum boards with PCM included: Thermal energy storage in buildings through latent heat, Energy and Buildings, 48, 1, 10.1016/j.enbuild.2012.01.026 · DOI
- Liu, 2009, Performance of phase change material boards under natural convection, Building and Environment, 44, 1788, 10.1016/j.buildenv.2008.12.002 · DOI
- Shilei, 2007, Experimental study and evaluation of latent heat storage in phase change materials wallboards, Energy and Buildings, 39, 1088, 10.1016/j.enbuild.2006.11.012 · DOI
- Shilei, 2006, Impact of phase change wall room on indoor thermal environment in winter, Energy and Buildings, 38, 18, 10.1016/j.enbuild.2005.02.007 · DOI
- Entrop, 2011, Experimental research on the use of micro-encapsulated Phase Change Materials to store solar energy in concrete floors and to save energy in Dutch houses, Solar Energy, 85, 1007, 10.1016/j.solener.2011.02.017 · DOI
- Cabeza, 2007, Use of microencapsulated PCM in concrete walls for energy savings, Energy and Buildings, 39, 113, 10.1016/j.enbuild.2006.03.030 · DOI
- Arce, 2012, Use of microencapsulated PCM in buildings and the effect of adding awnings, Energy and Buildings, 44, 88, 10.1016/j.enbuild.2011.10.028 · DOI
- Hunger, 2009, The behaviour of self-compacting concrete containing micro-encapsulated phase change materials, Cement and Concrete Composites, 31, 731, 10.1016/j.cemconcomp.2009.08.002 · DOI
- Pomianowski, 2012, A new experimental method to determine specific heat capacity of inhomogeneous concrete material with incorporated microencapsulated-PCM, Cement and Concrete Research
- Cheng, 2012, A new method to determine thermal physical properties of the mixture of PCM and concrete, Applied Energy
- Pomianowski, 2012, Dynamic heat storage and cooling capacity of a concrete deck with PCM and thermally activated building system, Energy and Buildings, 53, 96, 10.1016/j.enbuild.2012.07.007 · DOI
- Alawadhi, 2007, Thermal analysis of a building brick containing phase change material, Energy and Buildings, 40, 351, 10.1016/j.enbuild.2007.03.001 · DOI
- Castell, 2010, Experimental study of using PCM in brick constructive solutions for passive cooling, Energy and Buildings, 42, 534, 10.1016/j.enbuild.2009.10.022 · DOI
- Silva, 2012, Experimental testing and numerical modelling of masonry solution with PCM incorporation: a passive construction solution, Energy and Buildings, 49, 235, 10.1016/j.enbuild.2012.02.010 · DOI
- Sari, 2009, Preparation, thermal properties and thermal reliability of palmitic acid/expanded graphite composite as form-stable PCM for thermal energy storage, Solar Energy Materials and Solar Cells, 93, 571, 10.1016/j.solmat.2008.11.057 · DOI
- Marin, 2005, Improvement of a thermal energy storage using plates with paraffin–graphite composite, Heat and Mass Transfer, 48, 2561, 10.1016/j.ijheatmasstransfer.2004.11.027 · DOI
- Cerón, 2011, Experimental tile with phase change materials (PCM) for building use, Energy and Buildings, 43, 1869, 10.1016/j.enbuild.2011.03.031 · DOI
- Koschenz, 2004, Development of a thermally activated ceiling panel with PCM for application in lightweight and retrofitted buildings, Energy and Buildings, 36, 567, 10.1016/j.enbuild.2004.01.029 · DOI
- Ansuini, 2011, Radiant floors with PCM for indoor temperature control, Energy and Buidlings, 43, 3019, 10.1016/j.enbuild.2011.07.018 · DOI
- Jin, 2011, Thermal analysis of a double layer phase change material floor, Applied Thermal Engineering, 31, 1576, 10.1016/j.applthermaleng.2011.01.023 · DOI
- Lin, 2004, Modeling and simualtion of under-floor electric heating system with shape-stabilized PCM plates, Building and Environment, 39, 1427, 10.1016/j.buildenv.2004.04.005 · DOI
- Manz, 1997, TIM-PCM external wall system for solar heating and daylighting, Solar Energy, 61, 369, 10.1016/S0038-092X(97)00086-8 · DOI
- Ismail, 2002, Parametric study on composite and PCM glass system, Energy Conversion and Management, 43, 973, 10.1016/S0196-8904(01)00083-8 · DOI
- Ismail, 2007, Comparison between PCM filled glass windows and absorbing gas filled windows, Energy and Buildings, 40, 710, 10.1016/j.enbuild.2007.05.005 · DOI
- Weinläder, 2005, PCM-facade-panel for daylighting and room heating, Solar Energy, 78, 177, 10.1016/j.solener.2004.04.013 · DOI
- Weinläder, 2011, Monitoring results of an interior sun protection system with integrated latent heat storage, Energy and Buildings, 43, 2468, 10.1016/j.enbuild.2011.06.007 · DOI
- Alawadhi, 2012, Using phase change material in window shutter to reduce the solar heat gain, Energy and Buildings, 47, 421, 10.1016/j.enbuild.2011.12.009 · DOI
- Turnpenny, 2000, Novel ventilation cooling system for reducing air conditioning in buildings. Part 1: testing and theoretical modeling, Applied Thermal Engineering, 20, 1019, 10.1016/S1359-4311(99)00068-X · DOI
- Vakilaltojjar, 2001, Analysis and modeling of a phase change storage system for air conditioning applications, Applied Thermal Engineering, 21, 249, 10.1016/S1359-4311(00)00037-5 · DOI
- Kondo, 2006, Research on thermal storage using rock wool phase-change material ceiling board, ASHRAE Transactions, 112, 526
- Zhou, 2009, Numerical analysis of effect of shape-stabilized phase change material plates in a building combined with night ventilation, Applied Energy, 86, 52, 10.1016/j.apenergy.2008.03.020 · DOI
- Zhou, 2011, Energy performance of a hybrid space-cooling system in an office building using SSPCM thermal storage and night ventilation, Solar Energy, 85, 477, 10.1016/j.solener.2010.12.028 · DOI
- Hiki, 2004, Accuracy improvement of T-history method for measuring heat of fusion of various materials, International Journal of Refrigeration, 27, 360, 10.1016/j.ijrefrig.2003.12.006 · DOI
- Lázaro, 2006, Verification of T-history installation to measure enthalpy versus temperature curves of phase change materials, Measurement Science and Technology, 17, 2168, 10.1088/0957-0233/17/8/016 · DOI
- Frusteri, 2005, Thermal conductivity measurement of a PCM based storage system containing carbon fibers, Applied Thermal Engineering, 25, 1623, 10.1016/j.applthermaleng.2004.10.007 · DOI
- Sari, 2007, Thermal conductivity and latent heat thermal energy storage characteristics of paraffin/expanded graphite composite as phase change material, Applied Thermal Engineering, 27, 1271, 10.1016/j.applthermaleng.2006.11.004 · DOI
- Eman-Bellah Mettawee, 2007, Thermal conductivity enhancement in a latent heat storage system, Solar Energy, 81, 839, 10.1016/j.solener.2006.11.009 · DOI
- Velraj, 1998, Heat transfer enhancement in a latent heat storage system, Solar Energy, 65, 171, 10.1016/S0038-092X(98)00128-5 · DOI
- Hoogendoorn, 1992, Performance and modeling of latent heat stores, Solar Energy, 48, 53, 10.1016/0038-092X(92)90176-B · DOI
- Zhao, 2010, Heat transfer enhancement for thermal energy storage using metal foams embedded within phase change materials (PCMs), Solar Energy, 84, 1402, 10.1016/j.solener.2010.04.022 · DOI
- Zhang, 2006, Influence of additives on thermal conductivity of shape-stabilized phase change material, Solar Energy Materials and Solar Cells, 90, 1692, 10.1016/j.solmat.2005.09.007 · DOI
- Zhang, 2004, Development of thermal energy storage concrete, Cement and Concrete Research, 34, 924, 10.1016/j.cemconres.2003.10.022 · DOI
- Tian, 2011, A numerical investigation of heat transfer in phase change materials (PCMs) embedded in porous metals, Energy, 36, 5539, 10.1016/j.energy.2011.07.019 · DOI
- Zhang, 1996, Heat transfer enhancement in latent heat thermal energy storage system by using the internally finned tube, International Journal of Heat Mass Transfer, 39, 3165, 10.1016/0017-9310(95)00402-5 · DOI
- Ismail, 2001, Numerical and experimental study on the solidification of PCM around a vertical axially finned isothermal cylinder, Applied Thermal Engineering, 21, 53, 10.1016/S1359-4311(00)00002-8 · DOI
- Choi, 1992, Heat-transfer characteristics of a latent heat storage system using MgCl2 6H2O, Energy, 17, 1153, 10.1016/0360-5442(92)90004-J · DOI
- Kukulka, 2011, Development and evaluation of enhanced heat transfer tubes, Applied Thermal Engineering, 31, 2141, 10.1016/j.applthermaleng.2011.01.024 · DOI
- Bilen, 2009, The investigation of grooved geometry effect on heat transfer for internally grooved tubes, Applied Thermal Engineering, 29, 753, 10.1016/j.applthermaleng.2008.04.008 · DOI
- Pomianowski, 2012, Full-scale investigation of the dynamic heat storage of concrete decks with PCM and enhanced heat transfer surface area, Energy and Buildings, 59, 287, 10.1016/j.enbuild.2012.12.013 · DOI
- Olesen, 2000, Heat exchange coefficient between floor surface and space by floor cooling – theory or a question of definition, ASHRAE transactions, 106, 684
- Artmann, 2010, Experimental investigation of heat transfer during night-time ventilation, Energy and Buildings, 42, 366, 10.1016/j.enbuild.2009.10.003 · DOI
- Le Dréau, 2010, Experimental investigation of convective heat transfer during night cooling with different ventilation systems and surface emissivities, Energy and Building, 61, 308, 10.1016/j.enbuild.2013.02.021 · DOI
- Churchill, 1972, A general expression for the correlation of rates of heat transfer and other phenomena, AlChE Journal, 18, 1121, 10.1002/aic.690180606 · DOI
Cited by
Sorted by citations
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Self-citationPassive Temperature Control of an Outdoor Photobioreactor by Phase Change Materials
Uyar, B., & Kapucu, N. (2015) · Journal of Chemical Technology & Biotechnology · doi:10.1002/jctb.4398 · Cited by 25
Metadata
- Authors
- Pomianowski, M., Heiselberg, P., & Zhang, Y.
- Affiliations
- Aalborg University (DK)
- Tsinghua University (CN)
- Corresponding author
- Pomianowski, Michal
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 67
- Pages
- 56-69
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2068645089
- Cited by
- 474
- References
- 0
- Citations by year
- 2026: 40 · 2025: 31 · 2024: 27 · 2023: 34 · 2022: 31 · 2021: 44 · 2020: 52 · 2019: 45 · 2018: 34 · 2017: 42 · 2016: 38 · 2015: 42 · 2014: 14
- FWCI
- 41.57
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Energy and Buildings (publishedVersion)
- VBN Forskningsportal (Aalborg Universitet) (submittedVersion)
- Funders
- the Danish Agency for Science, Technology and Innovation
- the Ministry of Science and Technology of P.R. China
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Phase Change Materials Research
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- thermal energy storage, phase change materials, building applications, indoor thermal environment, thermal inertia, building energy consumption, composite phase change materials, energy saving potential
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review