The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Occupancy measurement in commercial office buildings for demand-driven control applications—A survey and detection system evaluation
Open accessAbstract
Commercial office buildings represent the largest in floor area in most developed countries and utilize substantial amount of energy in the provision of building services to satisfy occupants’ comfort needs. This makes office buildings a target for occupant-driven demand control measures, which have been demonstrated as having huge potential to improve energy efficiency. The application of occupant-driven demand control measures in buildings, most especially in the control of thermal, visual and indoor air quality providing systems, which account for over 30% of the energy consumed in a typical office building is however hampered due to the lack of comprehensive fine-grained occupancy information. Given that comprehensive fine-grained occupancy information improves the performance of demand-driven measures, this paper presents a review of common existing systems utilized in buildings for occupancy detection. Furthermore, experimental results from the performance evaluation of chair sensors in an office building for providing fine-grained occupancy information for demand-driven control applications are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649 · cited 1×
“value of E without compromising on comfort, a number of demand optimization, supply-air-temperature reset and ventilation optimization, are often commonly employed by control engineers in the design and operation of HVAC systems [13,18–20].”
The Cricket location-support system
Priyantha, N. B., Chakraborty, A., & Balakrishnan, H. (2000) · Proceedings of the 6th annual international conference on Mobile computing and networking · doi:10.1145/345910.345917 · Cited by 3,716
Farhangi, H. (2010) · IEEE Power and Energy Magazine · doi:10.1109/mpe.2009.934876 · Cited by 2,870
Ventilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 2,497
Demand response and smart grids – a survey
Siano, P. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.10.022 · Cited by 2,411
Energy intelligent buildings based on user activity: A survey
Nguyen, T. A., & Aiello, M. (2013) · Energy and Buildings · doi:10.1016/j.enbuild.2012.09.005 · Cited by 714
Localization systems for wireless sensor networks
Boukerche, A., & Nakamura, E. (2007) · IEEE Wireless Communications · doi:10.1109/mwc.2007.4407221 · Cited by 689
Progress in thermal comfort research over the last twenty years
de Dear, R. J., Akimoto, T., Arens, E. A., Brager, G., Candido, C., Cheong, K. W. D., Li, B., Nishihara, N., Sekhar, S. C., Tanabe, S., et al. (2013) · Indoor Air · doi:10.1111/ina.12046 · Cited by 523
95/05538 International energy outlook 1994
(1995) · Fuel and Energy Abstracts · doi:10.1016/0140-6701(95)97259-m · Cited by 398
Importance of occupancy information for building climate control
Oldewurtel, F., Sturzenegger, D., & Morari, M. (2013) · Applied Energy · doi:10.1016/j.apenergy.2012.06.014 · Cited by 382
Cited by
Candanedo, L. M., & Feldheim, V. (2016) · Energy and Buildings · doi:10.1016/j.enbuild.2015.11.071 · Cited by 586
A review of smart building sensing system for better indoor environment control
Dong, B., Prakash, V., Feng, F., & O'Neill, Z. (2019) · Energy and Buildings · doi:10.1016/j.enbuild.2019.06.025 · Cited by 360
Using machine learning techniques for occupancy-prediction-based cooling control in office buildings
Peng, Y., Rysanek, A., Nagy, Z., & Schlüter, A. (2018) · Applied Energy · doi:10.1016/j.apenergy.2017.12.002 · Cited by 332
Building occupancy estimation and detection: A review
Chen, Z., Jiang, C., & Xie, L. (2018) · Energy and Buildings · doi:10.1016/j.enbuild.2018.03.084 · Cited by 280
Jung, W., & Jazizadeh, F. (2019) · Applied Energy · doi:10.1016/j.apenergy.2019.01.070 · Cited by 276
Metadata
- Authors
- Labeodan, T., Zeiler, W., Boxem, G., & Zhao, Y.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2015-04
- Volume
- 93
- Pages
- 303-314
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W1984515777
- Cited by
- 322
- References
- 37
- FWCI
- 46.43
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Occupancy measurement in commercial office buildings for demand-driven control applications—A survey and detection system evaluation. https://app.cochat.ai/papers/10.1016/j.enbuild.2015.02.028
- The paper
- Labeodan, T., Zeiler, W., Boxem, G., & Zhao, Y. (2015). Occupancy measurement in commercial office buildings for demand-driven control applications—A survey and detection system evaluation. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2015.02.028
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.