Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Abstract Retrofit on existing buildings for better energy performance is widely desired due to large share of building energy consumption. Meanwhile, the importance of thermal comfort and air pollution exposure has attracted increasing attention for occupant health, productivity and sustainable development. Heat, ventilation and air conditioning (HVAC) systems are responsible for a substantial proportion of energy use in buildings and are closely related to indoor environment quality. This study examined the energy consumption and indoor environment in a commercial office building with a retrofitted HVAC system. The retrofitting measures included a sensor-based building management system, dehumidification of outdoor air, and a two-stage particle filtration system. Energy data were collected before and after the retrofit. Field measurements were conducted in both winter and summer to evaluate the thermal comfort and indoor exposure to air pollutants in the retrofitted area. An experiment was designed to assess the benefits of upgraded filters on exposure to ambient particles during summer. By combining all of these measures, the retrofitted HVAC system was able to reduce energy use by 50% while maintaining generally acceptable indoor thermal comfort. Most of the time, the indoor particle levels complied with the World Health Organization's guidelines. The upgraded filtration system with a pleated filter reduced outdoor PM ingress by 30% to 60% more than the aluminum filter used before the retrofit. Co-benefit assessment provides insights into sustainability in building development during a retrofit by holistically examining energy use and the environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
Indoor particulate matter of outdoor origin: Importance of size-dependent removal mechanisms
Riley, W. J., McKone, T. E., Lai, A. C. K., & Nazaroff, W. W. (2002) · Environmental Science & Technology · doi:10.1021/es010723y · Cited by 417
Cited by
Measuring the productivity impacts of energy-efficiency: The case of high-efficiency buildings
Chatterjee, S., & Ürge-Vorsatz, D. (2021) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2021.128535 · Cited by 36
Tayefeh, A., Aslani, A., Zahedi, R., & Yousefi, H. (2024) · Cleaner Energy Systems · doi:10.1016/j.cles.2024.100124 · Cited by 20
Metadata
- Authors
- Che, W. W., Tso, C. Y., Sun, L., Ip, D. Y. K., Lee, H., Chao, C. Y. H., & Lau, A. K. H.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 201
- Pages
- 202-215
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2952077590
- Cited by
- 240
- References
- 3
- FWCI
- 13.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system. https://app.cochat.ai/papers/10.1016/j.enbuild.2019.06.029
- The paper
- Che, W. W., Tso, C. Y., Sun, L., Ip, D. Y. K., Lee, H., Chao, C. Y. H., & Lau, A. K. H. (2019). Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2019.06.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.