CoChat

Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system

Che, Wen Wei, Tso, Chi Yan, Sun, Li, Ip, Danny Y.K., Lee, Harry, Chao, Christopher Y.H., Lau, Alexis K.H. · 2019 · Energy and Buildings
Cited by 240

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Abstract Retrofit on existing buildings for better energy performance is widely desired due to large share of building energy consumption. Meanwhile, the importance of thermal comfort and air pollution exposure has attracted increasing attention for occupant health, productivity and sustainable development. Heat, ventilation and air conditioning (HVAC) systems are responsible for a substantial proportion of energy use in buildings and are closely related to indoor environment quality. This study examined the energy consumption and indoor environment in a commercial office building with a retrofitted HVAC system. The retrofitting measures included a sensor-based building management system, dehumidification of outdoor air, and a two-stage particle filtration system. Energy data were collected before and after the retrofit. Field measurements were conducted in both winter and summer to evaluate the thermal comfort and indoor exposure to air pollutants in the retrofitted area. An experiment was designed to assess the benefits of upgraded filters on exposure to ambient particles during summer. By combining all of these measures, the retrofitted HVAC system was able to reduce energy use by 50% while maintaining generally acceptable indoor thermal comfort. Most of the time, the indoor particle levels complied with the World Health Organization's guidelines. The upgraded filtration system with a pleated filter reduced outdoor PM ingress by 30% to 60% more than the aluminum filter used before the retrofit. Co-benefit assessment provides insights into sustainability in building development during a retrofit by holistically examining energy use and the environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enbuild.2019.06.029

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 240

Metadata

Authors
Che, W. W., Tso, C. Y., Sun, L., Ip, D. Y. K., Lee, H., Chao, C. Y. H., & Lau, A. K. H.
Venue
Energy and Buildings
Publisher
Elsevier BV
Published
2019-10
Volume
201
Pages
202-215
ISSN
0378-7788 (ISSN-L)
OpenAlex
W2952077590
Cited by
240
References
3
FWCI
13.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system. https://app.cochat.ai/papers/10.1016/j.enbuild.2019.06.029
The paper
Che, W. W., Tso, C. Y., Sun, L., Ip, D. Y. K., Lee, H., Chao, C. Y. H., & Lau, A. K. H. (2019). Energy consumption, indoor thermal comfort and air quality in a commercial office with retrofitted heat, ventilation and air conditioning (HVAC) system. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2019.06.029

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.