Coupled simulation of thermally active building systems to support a digital twin
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Based on 2050 Swiss and European Union targets, significant energy performance improvements will be required for new and renovated buildings. However, the construction industry has a poor record for delivering productivity and efficiency advancement. As proven in other industries, digital methods can shorten product development time and cost by reducing prototyping with the use of numerical simulation. Further, a digital twin is an extensive computational model of a product that is planned to improve over its lifecycle by leveraging operational data. This paper presents a coupled simulation for the thermal design of a heating and cooling system that is integrated with a lightweight roof structure. The concrete roof structure is shape optimised to provide a low embodied energy building element, which is thermally activated to supply space conditioning from a renewable geothermal source. This work is focused on the modelling methodology used by the energy domain to support the development of a digital twin for a multifunctional building element. High-resolution analysis is used to resolve building physics issues and to provide the initial system performance. A parametric geometry model is used to apply the hydronic pipework to a complex roof shape. With input from the previous two steps, a reduced resolution method is used to add the characteristics of the system to an industry standard whole building simulation model. This final step allows for the development of initial control strategies for the novel multifunctional element. The implications of the research findings are discussed in the context of possible alternations to the building design process due to the influence of digital fabrication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Shaping the digital twin for design and production engineering
Schleich, B., Anwer, N., Mathieu, L., & Wartzack, S. (2017) · CIRP Annals · doi:10.1016/j.cirp.2017.04.040 · Cited by 1,305
Energy use in the life cycle of conventional and low-energy buildings: A review article
Sartori, I., & Hestnes, A. G. (2007) · Energy and Buildings · doi:10.1016/j.enbuild.2006.07.001 · Cited by 1,284
Cited by
Digital twin application in the construction industry: A literature review
Opoku, D.-G. J., Perera, S., Osei-Kyei, R., & Rashidi, M. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2021.102726 · Cited by 753
Digital twin and its implementations in the civil engineering sector
Jiang, F., Ma, L., Broyd, T., & Chen, K. (2021) · Automation in Construction · doi:10.1016/j.autcon.2021.103838 · Cited by 500
Integrating BIM and AI for Smart Construction Management: Current Status and Future Directions
Pan, Y., & Zhang, L. (2023) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-022-09830-8 · Cited by 441
A comprehensive review of digital twin — part 1: modeling and twinning enabling technologies
Thelen, A., Zhang, X., Fink, O., Lu, Y., Ghosh, S., Youn, B. D., Todd, M. D., Mahadevan, S., Hu, C., & Hu, Z. (2022) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-022-03425-4 · Cited by 441
Deng, M., Menassa, C. C., & Kamat, V. R. (2021) · Journal of Information Technology in Construction · doi:10.36680/j.itcon.2021.005 · Cited by 422
Metadata
- Authors
- Lydon, G. P., Caranovic, S., Hischier, I., & Schlueter, A.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 202
- Pages
- 109298
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2967522383
- Cited by
- 144
- References
- 2
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.