Experimental short-term investigation of model predictive heat pump control in residential buildings
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
This study investigates the potential of model predictive heat pump control in detached houses in terms of electric energy consumption, thermal comfort and photovoltaic energy self-consumption. Two comparable test rigs with identical devices are set up. The test rigs include electrical air source heat pumps with variable compressor speed, thermal energy storages and heat dissipation by heat exchangers. The heat demand is controlled by valves, which are coupled to real-time simulation of building models in compliance with the principle of energy conservation. Measurements confirm test rig comparability. After introducing the model predictive control (MPC) concept, a successive series of six measurements of 120 h each within the heating season is presented. The model predictive heat pump controller is evaluated by comparison to a standard heat pump controller implemented into the reference test rig. Results show an average increase of the heat pump coefficient of performance of 22.2%, an average increase of 234.8% in terms of photovoltaic energy self-consumption as well as a resulting average heat pump operational cost reduction of 34.0% by application of MPC.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Error Analysis: The Study of Uncertainties in Physical Measurements
Taylor, J. R., & Thompson, W. (1998) · Physics Today · doi:10.1063/1.882103 · Cited by 2,734
Ten Questions Concerning Model Predictive Control for Energy Efficient Buildings
Killian, M., & Kozek, M. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.05.034 · Cited by 463
Cited by
Yao, Y., & Shekhar, D. K. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.107952 · Cited by 447
Kim, D., Lee, J., Do, S., Mago, P. J., Lee, K. H., & Cho, H. (2022) · Energies · doi:10.3390/en15197231 · Cited by 111
“The MPC performance to control a conventional AHU system and a DOAS-integrated SSLC system was investigated experimentally and compared against a conventional feedback-control-based building management system (BMS).”
MethodField test of Model Predictive Control in residential buildings for utility cost savings
Wang, D., Chen, Y., Wang, W., Gao, C., & Wang, Z. (2023) · Energy and Buildings · doi:10.1016/j.enbuild.2023.113026 · Cited by 84
Hu, Z., Gao, Y., Sun, L., Mae, M., & Imaizumi, T. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123652 · Cited by 52
Metadata
- Authors
- Kuboth, S., Heberle, F., Weith, T., Welzl, M., König-Haagen, A., & Brüggemann, D.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2019-12
- Volume
- 204
- Pages
- 109444
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2979031953
- Cited by
- 49
- References
- 2
- FWCI
- 2.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental short-term investigation of model predictive heat pump control in residential buildings. https://app.cochat.ai/papers/10.1016/j.enbuild.2019.109444
- The paper
- Kuboth, S., Heberle, F., Weith, T., Welzl, M., König-Haagen, A., & Brüggemann, D. (2019). Experimental short-term investigation of model predictive heat pump control in residential buildings. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2019.109444
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.