Nudging the adaptive thermal comfort model
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
The recent release of the largest database of thermal comfort field studies (ASHRAE Global Thermal Comfort Database II) presents an opportunity to perform a quality assurance exercise on the first generation adaptive comfort standards (ASHRAE 55 and EN15251). The analytical procedure used to develop the ASHRAE 55 adaptive standard was replicated on 60,321 comfort questionnaire records with accompanying measurement data. Results validated the standard's current adaptive comfort model for naturally ventilated buildings, while suggesting several potential nudges relating to the adaptive comfort standards, adaptive comfort theory, and building operational strategies. Adaptive comfort effects were observed in all regions represented in the new global database, but the neutral (comfort) temperatures in the Asian subset trended 1–2 °C higher than in Western countries. Moreover, sufficient data allowed the development of an adaptive model for mixed-mode buildings that closely aligned to the naturally ventilated counterpart. We present evidence that adaptive comfort processes are relevant to the occupants of all buildings, including those that are air conditioned, as the thermal environmental exposures driving adaptation occur indoors where we spend most of our time. This suggests significant opportunity to transition air conditioning practice into the adaptive framework by programming synoptic- and seasonal-scale set-point nudging into building automation systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
R: A Language and Environment for Statistical Computing
R Core Team (2025) · doi:10.32614/r.manuals · Cited by 352,181
bibliometrix: An R-tool for comprehensive science mapping analysis
Aria, M., & Cuccurullo, C. (2017) · Journal of Informetrics · doi:10.1016/j.joi.2017.08.007 · Cited by 16,064
Nudge: improving decisions about health, wealth, and happiness
(2008) · Choice Reviews Online · doi:10.5860/choice.46-0977 · Cited by 11,572
Thermal comfort: Analysis and applications in environmental engineering
(1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,451
(1998) · eScholarship (California Digital Library) · Cited by 1,934
Adaptive thermal comfort and sustainable thermal standards for buildings
Nicol, J. F., & Humphreys, M. A. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00006-3 · Cited by 1,850 · cited 1×
“To encourage such a shift in practice, standards bodies such as ASHRAE should relax the tight guidelines on air conditioned buildings, most of which are premised on the artificial precision of the PMV/PPD model’s predictions (Humphreys & Nicol, 2002; Cheung et al., 2019).”
MethodThermal adaptation in the built environment: a literature review
Brager, G. S., & de Dear, R. J. (1998) · Energy and Buildings · doi:10.1016/s0378-7788(97)00053-4 · Cited by 1,483 · cited 9×
“Replicating the analysis of de Dear & Brager (1998) showed that the relationship between comfort temperatures and outdoor conditions for NV buildings (Figure 4) is very similar to what was reported over twenty years ago on a smaller database.”
InfluentialSelf-citationThermal comfort and building energy consumption implications—A review
Yang, L., Yan, H., & Lam, J. C. (2014) · Applied Energy · doi:10.1016/j.apenergy.2013.10.062 · Cited by 1,448
A Dynamic Model of Stress and Sustained Attention
Hancock, P. A. (1989) · Human Factors: The Journal of the Human Factors and Ergonomics Society · doi:10.1177/001872088903100503 · Cited by 874 · cited 1×
“The science underpinning the putative optimum performance temperature of 22°C has been thoroughly debunked (e.g. Hancock 1989; Hancock and Ganey, 2003; Zhang et al. 2019) and supplanted by the “extended-U” model.”
BackgroundExtension of the PMV model to non-air-conditioned buildings in warm climates
Ole Fanger, P., & Toftum, J. (2002) · Energy and Buildings · doi:10.1016/s0378-7788(02)00003-8 · Cited by 853
Cited by
Jay, O., Capon, A., Berry, P., Broderick, C., de Dear, R., Havenith, G., Honda, Y., Kovats, R. S., Ma, W., Malik, A., et al. (2021) · The Lancet · doi:10.1016/s0140-6736(21)01209-5 · Cited by 737
Self-citationA review of adaptive thermal comfort research since 1998
de Dear, R., Xiong, J., Kim, J., & Cao, B. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109893 · Cited by 258
Self-citationSome evidence of a time-varying thermal perception
Vellei, M., O’Brien, W., Martinez, S., & Le Dréau, J. (2022) · Indoor and Built Environment · doi:10.1177/1420326x211034563 · Cited by 11
Metadata
- Authors
- Parkinson, T., de Dear, R., & Brager, G.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 206
- Pages
- 109559
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W2983173659
- Cited by
- 216
- References
- 53
- FWCI
- 15.12
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.