Indoor environmental quality related risk factors with energy-efficient retrofitting of housing: A literature review
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
There are indications that energy-retrofitted buildings can create risks for indoor environmental quality (IEQ) and therefore for health and comfort of occupants. A review was conducted to identify and verify those risks, within three themes: building envelope, heating, ventilating and air conditioning (HVAC)-systems, and occupants. Publications from the last five years in major peer-reviewed journals from different fields (energy, buildings, indoor air, social sciences) were found by using a variety of keywords (health effects, occupant behaviours, energy-efficient retrofitting, etc.). For the building envelope, retrofitted buildings tend to be air-tighter and more thermally insulated. Hence, humidity problems, build-up of pollutants, and overheating may occur. Installing HVAC-systems and issues within (ducts, filters, maintenance, noise) may also compromise IEQ. Although relationships are difficult to establish, evidence shows that certain retrofits increase the risk of health problems, particularly for airways, skin, and eyes. Despite the installation of energy-retrofitting technologies, not all buildings lower their energy consumption. This is partly due to occupants (behaviours, preferences, needs, awareness) and partly due to technical issues. The studies reviewed, mainly focused on the performance gaps of energy-retrofitted homes and on energy-saving measures. “Comfort” and “health” tend to be disregarded, with both being seldom measured and only assessed by simulation. Occupant behaviours, preferences, and needs are understudied and need to be incorporated into the research and development of retrofitting measures. More interdisciplinary approaches are needed, in which buildings & HVAC-systems, occupants, health and comfort, and IEQ are investigated as interacting elements and based on an integrated approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The theory of planned behavior
Ajzen, I. (1991) · Organizational Behavior and Human Decision Processes · doi:10.1016/0749-5978(91)90020-t · Cited by 90,587
Going green to be seen: status, reputation, and conspicuous conservation
Griskevicius, V., Tybur, J. M., & Van den Bergh, B. (2010) · Journal of Personality and Social Psychology · doi:10.1037/a0017346 · Cited by 2,174
Energy efficiency and consumption—The rebound effect—A survey
A. Greening, L., Greene, D. L., & Difiglio, C. (2000) · Energy Policy · doi:10.1016/s0301-4215(00)00021-5 · Cited by 2,077
Bornehag, C. G., Sundell, J., Hagerhed-Engman, L., Sigsggard, T., Janson, S., Aberg, N., & DBH Study Group (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00306.x · Cited by 250
Shorter, C., Crane, J., Pierse, N., Barnes, P., Kang, J., Wickens, K., Douwes, J., Stanley, T., Täubel, M., Hyvärinen, A., et al. (2018) · Indoor Air · doi:10.1111/ina.12413 · Cited by 72
Cited by
Alabid, J., Bennadji, A., & Seddiki, M. (2022) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2022.112161 · Cited by 131
Metadata
- Authors
- Ortiz, M., Itard, L., & Bluyssen, P. M.
- Venue
- Energy and Buildings
- Publisher
- Elsevier BV
- Published
- 2020-08
- Volume
- 221
- Pages
- 110102
- ISSN
- 0378-7788 (ISSN-L)
- OpenAlex
- W3020944295
- Cited by
- 178
- References
- 5
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Indoor environmental quality related risk factors with energy-efficient retrofitting of housing: A literature review. https://app.cochat.ai/papers/10.1016/j.enbuild.2020.110102
- The paper
- Ortiz, M., Itard, L., & Bluyssen, P. M. (2020). Indoor environmental quality related risk factors with energy-efficient retrofitting of housing: A literature review. Energy and Buildings. https://doi.org/10.1016/j.enbuild.2020.110102
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.