The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Air-cooled LiBr–water absorption chillers for solar air conditioning in extremely hot weathers
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“It was found that when the ambient temperature increases to 50 °C from 35 °C, the cooling capacity of the absorption chiller decreases 37.5% and 35.6% for direct air-cooled chiller and indirect air-cooled chiller compared with their cooling capacity at 35 °C, respectively.”
From Resilient cooling strategies – A critical review and qualitative assessment (2021) · cites this paper as [205]
Citations
Cites
Solar refrigeration options – a state-of-the-art review
Kim, D.-S., & Ferreira, C. A. I. (2007) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2007.07.011 · Cited by 528
Self-citationSolar air conditioning in Europe—an overview
Balaras, C. A., Grossman, G., Henning, H.-M., Infante Ferreira, C. A., Podesser, E., Wang, L., & Wiemken, E. (2007) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2005.02.003 · Cited by 428
Baehr, H. D., & Stephan, K. (2010) · Springer eBooks · doi:10.1007/978-3-642-10194-6 · Cited by 362
Solar/waste heat driven two-stage adsorption chiller: the prototype
Saha, B. B., Akisawa, A., & Kashiwagi, T. (2001) · Renewable Energy · doi:10.1016/s0960-1481(00)00107-5 · Cited by 252
Applied numerical methods for digital computation
James, M. L., Smith, G. M., & Wolford, J. C. (1985) · Cited by 222
Experimental investigation of a liquid desiccant system for solar cooling and dehumidification
Gommed, K., & Grossman, G. (2007) · Solar Energy · doi:10.1016/j.solener.2006.05.006 · Cited by 202
Solar absorption cooling with low grade heat source — a strategy of development in South China
Sumathy, K., Huang, Z. C., & Li, Z. F. (2002) · Solar Energy · doi:10.1016/s0038-092x(01)00098-6 · Cited by 117
Izquierdo, M. (2003) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2003.11.002 · Cited by 98
Velázquez, N., & Best, R. (2002) · Applied Thermal Engineering · doi:10.1016/s1359-4311(02)00028-5 · Cited by 74
Medrano, M., Bourouis, M., & Coronas, A. (2002) · International Journal of Thermal Sciences · doi:10.1016/s1290-0729(02)01383-2 · Cited by 71
Research works printed but not linked: 7
- Lokurlu A, Müller G. Experiences with the worldwide first solar cooling system based on trough collectors combined with double effect absorption chillers. In: Proceedings of international conference solar air-conditioning, Bad Staffelstein, Germany; 2005.
- Kim DS, Machielsen CHM. Evaluation of air-cooled solar absorption cooling systems. In: Proceedings of ISHPC, 2002, Shanghai, China.
- Sawada N, Tanaka T, Ikumi Y, Kobayashi T. Study on air-cooled absorption system for light commercial use. In: Proceedings of absorption heat pump conference, 1991, Tokyo, Japan.
- Ogawa M, Hoshida T, Oda Y. Study on heat transfer analysis for the vertical condenser/absorber of an air-cooling absorption chiller/heater. In: Proceedings of absorption heat pump conference, 1991, Tokyo, Japan.
- Nakoryakov, 1980, Calculation of heat and mass transfer in nonisothermal absorption on the initial portion of a downflowing film, Teoreticheskie Osnovy Khimicheskoi Tekhnologii, 14, 483
- Safarik M, Richter L, Mockel F, Kretschmar S. Performance data of a small capacity absorption chiller. In: Proceedings of international conference solar air-conditioning, Bad Staffelstein, Germany, 2005.
- Storkenmaier F, Harm M, Schweigler C, Ziegler F, Albers J, Kohlenbach P, et al. Small-capacity water/LiBr absorption chiller for solar cooling and waste-heat driven cooling. In: Proceedings of international congress of refrigeration, Washington DC, USA, 2003.
Cited by
A review of solar thermal refrigeration and cooling methods
Ullah, K., Saidur, R., Ping, H. W., Akikur, R. K., & Shuvo, N. H. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.024 · Cited by 278
Review of solar cooling methods and thermal storage options
Chidambaram, L. A., Ramana, A. S., Kamaraj, G., & Velraj, R. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.04.018 · Cited by 255
A review for research and new design options of solar absorption cooling systems
Zhai, X. Q., Qu, M., Li, Y., & Wang, R. Z. (2011) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2011.06.016 · Cited by 190
Resilient cooling strategies – A critical review and qualitative assessment
Zhang, C., Kazanci, O. B., Levinson, R., Heiselberg, P., Olesen, B. W., Chiesa, G., Sodagar, B., Ai, Z., Selkowitz, S., Zinzi, M., et al. (2021) · Energy and Buildings · doi:10.1016/j.enbuild.2021.111312 · Cited by 180
Absorption refrigeration cycles: Categorized based on the cycle construction
Xu, Z., & Wang, R. Z. (2015) · International Journal of Refrigeration · doi:10.1016/j.ijrefrig.2015.10.007 · Cited by 151
Metadata
- Authors
- Kim, D. S., & Infante Ferreira, C. A.
- Corresponding author
- Kim, D.S.
- ORCID
- Kim, D.S.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2009-04
- Volume
- 50
- Issue
- 4
- Pages
- 1018-1025
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2078517608
- Cited by
- 92
- References
- 19
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 4 · 2022: 3 · 2021: 7 · 2020: 8 · 2019: 9 · 2018: 3 · 2017: 7 · 2016: 6 · 2015: 6 · 2014: 6 · 2013: 6 · 2012: 7
- FWCI
- 15.37
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Energy Conversion and Management (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
- Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
- Physical Sciences › Engineering › Mechanical Engineering › Thermodynamic and Exergetic Analyses of Power and Cooling Systems
- Keywords
- solar cooling, flat plate solar collector, hot arid climate, two-phase heat exchangers, falling film flow, heat and mass transfer resistance, coefficient of performance, ambient temperature effects
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Air-cooled LiBr–water absorption chillers for solar air conditioning in extremely hot weathers. https://app.cochat.ai/papers/10.1016/j.enconman.2008.12.021
- The paper
- Kim, D. S., & Infante Ferreira, C. A. (2009). Air-cooled LiBr–water absorption chillers for solar air conditioning in extremely hot weathers. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2008.12.021
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.