Deep residual network based fault detection and diagnosis of photovoltaic arrays using current-voltage curves and ambient conditions

Chen, Zhicong, Chen, Yixiang, Wu, Lijun, Cheng, Shuying, Lin, Peijie·2019·Energy Conversion and Management

Abstract

Abstract Automatic fault detection and diagnosis techniques for photovoltaic arrays are crucial to promote the efficiency, reliability and safety of photovoltaic systems. In recent decades, many conventional artificial intelligence approaches have been successfully applied to automatically establish fault detection and diagnosis model using fault data samples, but most of them rely on manual feature extraction or expert knowledge to build diagnosis models, which is inefficient and may ignore some potential useful features. In addition, they usually use shallow neural networks with limited performance. Addressing the issues, this paper proposes a novel intelligent fault detection and diagnosis method for photovoltaic arrays based on a newly designed deep residual network model trained by the adaptive moment estimation deep learning algorithm, which can automatically extract features from raw current-voltage curves and ambient irradiance and temperature, and effectively improve the performance with a deeper network. In order to validate the proposed fault diagnosis model, a Simulink based simulation model is designed for a real laboratory photovoltaic array, and both fault simulation and real experiments are carried out to obtain simulation and experimental fault datasets. Furthermore, two other popular deep learning based models are used for comparison, including convolution neural network and convolutional auto-encoder. Both of simulation and real experimental comparison results demonstrate that the proposed deep residual network based method achieves high and best overall performance in terms of accuracy, generalization performance, reliability and training efficiency.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2019.111793

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 44 references

Metadata

Authors
Chen, Z., Chen, Y., Wu, L., Cheng, S., & Lin, P.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2019-10
Volume
198
Pages
111793
ISSN
0196-8904 (ISSN-L)
OpenAlex
W2961566974
Cited by
347
References
44
FWCI
7.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Deep residual network based fault detection and diagnosis of photovoltaic arrays using current-voltage curves and ambient conditions. https://app.cochat.ai/papers/10.1016/j.enconman.2019.111793
The paper
Chen, Z., Chen, Y., Wu, L., Cheng, S., & Lin, P. (2019). Deep residual network based fault detection and diagnosis of photovoltaic arrays using current-voltage curves and ambient conditions. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2019.111793

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.