Model-based predictive control for optimal MicroCSP operation integrated with building HVAC systems
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a model predictive control (MPC) framework to minimize the energy consumption and the energy cost of the building heating, ventilation, and air-conditioning (HVAC) system integrated with a micro-scale concentrated solar power (MicroCSP) system that cogenerates electricity and heat. The mathematical model of a MicroCSP system is derived and integrated into the building thermal model of an office building at Michigan Technological University. Then, the MPC framework is used to optimize thermal energy storage (TES) system usage, the energy conversion in the Organic Rankine Cycle (ORC), and the thermal energy flows to the HVAC system. The MPC results for energy and cost savings show the significance of understanding system dynamics and designing a real-time predictive controller to maximize the benefits of MicroCSP thermal and electrical energies production. Indeed, the designed MPC framework provided 37% energy saving and 70% cost saving compared to the conventional rule-based controller (RBC). Furthermore, the MicroCSP integration into the building HVAC is compared to the alternative of integrating photovoltaic (PV) panels and battery energy storage (BES) system to address the building HVAC needs. The results show the MicroCSP system outperforms PV solar panels for energy saving, while the PV panels outperform the MicroCSP system for cost saving when dynamic pricing is applied.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wächter, A., & Biegler, L. T. (2006) · Mathematical Programming · doi:10.1007/s10107-004-0559-y · Cited by 9,483
Cited by
Mariano-Hernández, D., Hernández-Callejo, L., Zorita-Lamadrid, A., Duque-Pérez, O., & Santos García, F. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101692 · Cited by 484
Alkhatib, H., Lemarchand, P., Norton, B., & O'Sullivan, D. T. J. (2021) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2020.116331 · Cited by 126
Hu, Z., Gao, Y., Sun, L., Mae, M., & Imaizumi, T. (2024) · Applied Energy · doi:10.1016/j.apenergy.2024.123652 · Cited by 52
Chen, Y., Gao, J., Yang, J., Berardi, U., & Cui, G. (2023) · Applied Energy · doi:10.1016/j.apenergy.2022.120613 · Cited by 29
Metadata
- Authors
- Toub, M., Reddy, C. R., Razmara, M., Shahbakhti, M., Robinett, R. D., & Aniba, G.
- Venue
- Energy Conversion and Management
- Publisher
- Elsevier BV
- Published
- 2019-11
- Volume
- 199
- Pages
- 111924
- ISSN
- 0196-8904 (ISSN-L)
- OpenAlex
- W2972239117
- Cited by
- 58
- References
- 1
- FWCI
- 5.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Model-based predictive control for optimal MicroCSP operation integrated with building HVAC systems. https://app.cochat.ai/papers/10.1016/j.enconman.2019.111924
- The paper
- Toub, M., Reddy, C. R., Razmara, M., Shahbakhti, M., Robinett, R. D., & Aniba, G. (2019). Model-based predictive control for optimal MicroCSP operation integrated with building HVAC systems. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2019.111924
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.