CoChat

Coupling electrodialysis desalination with photovoltaic and wind energy systems for energy storage: Dynamic simulations and control strategy

Open access
Campione, Antonino, Cipollina, Andrea, Calise, Francesco, Tamburini, Alessandro, Galluzzo, Mosè, Micale, Giorgio · 2020 · Energy Conversion and Management
Cited by 64

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

The presence of desalination systems in polygeneration facilities is usually limited by important difficulties in operating under non-stationary regimes typical of renewable energy sources. Reverse osmosis, namely the most common desalination technology, is characterised by slow dynamics that rarely adapts to the power fluctuations of renewables. Therefore, the possibility of using electrodialysis coupled with a hybrid photovoltaic/wind energy source was investigated in this work. In particular, the combination of photovoltaic and wind energy is very attractive in order to achieve a more stable energy production, while electrodialysis is claimed to be a more flexible process compared to reverse osmosis. For this reason, the aim of this work was to analyse the technical advantages of using electrodialysis in the aforementioned scenarios, Suitable transitory simulation models are implemented for modelling electrodialysis units, photovoltaic panels and wind turbines. Dynamic scenarios were analysed, looking at two different time scales. Quasi steady-state simulations were used to study the yearly operation of 4 electrodialysis units operating in parallel, demonstrating process flexibility over a wide range of produced flowrates (from 920 to 230 m3/d) and power inputs (5–45 kW) when producing drinking water at a constant NaCl outlet concentration of 0.25 g/l. Dynamic simulations were adopted to study the daily time scale, where the desalination unit control system, purposely designed and tuned, was able to maintain a relatively stable target value in presence of disturbances in power availability, i.e. with a fluctuation of the outlet concentration lower than ± 10%, in between 0,23 and 0,27 g/l . Simulation results show how the electrodialysis process is particularly suitable for the integration within polygeneration systems as energy-buffer.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2020.112940

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Campione, A., Cipollina, A., Calise, F., Tamburini, A., Galluzzo, M., & Micale, G.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2020-07
Volume
216
Pages
112940
ISSN
0196-8904 (ISSN-L)
OpenAlex
W3031430807
Cited by
64
References
2
FWCI
2.88
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.