In this study, the optimal design and operation of an Organic Rankine Cycle (ORC) system driven by solar energy is investigated. A two-tank sensible thermal energy storage system is configured to overcome the intermittency of solar energy. A circulating fluid, also termed as heat transfer fluid (HTF) that connects the solar collector and the ORC system plays a critical role in this system. The mass flowrate of the HTF determines both the temperature of the HTF and the amount of heat absorbed from the solar collector. A simulation-based optimization model is developed in this work. Process simulation of the ORC is performed in Aspen HYSYS, and the mathematical models of the energy storage system and the parabolic trough collector are developed in Matlab. The optimal design of the system including the hot tank temperature, cold tank temperature, mass flowrate of the HTF, and operating conditions of the ORC are determined simultaneously based on the simulation-based optimization framework. The control strategy of the solar collector can be determined as well. The system efficiency of the solar energy driven ORC system is maximized with the proposed optimal operation strategy. With the simulation-based optimization framework, the system efficiency of the recuperative ORC power plant with toluene as the working fluid is increased from 17.9% to 24.8% compared with a previous study in the literature. The recuperative ORC performs much better than the basic ORC. Toluene performs best among all the investigated working fluids ignoring the problem with vacuum condensation. The cycle type (subcritical vs. supercritical) exerts great influence on the system performance. The supercritical ORC can improve the thermal efficiency by 11.3% and the overall system efficiency by 10.8% compared with the subcritical ORC with n-pentane as the working fluid.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.enconman.2021.114494

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 18 references

Cited by

See all 165

Metadata

Authors
Yu, H., Helland, H., Yu, X., Gundersen, T., & Sin, G.
Venue
Energy Conversion and Management
Publisher
Elsevier BV
Published
2021-09
Volume
244
Pages
114494
ISSN
0196-8904 (ISSN-L)
OpenAlex
W3177545586
Cited by
165
References
18
FWCI
12.46
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Optimal design and operation of an Organic Rankine Cycle (ORC) system driven by solar energy with sensible thermal energy storage. https://app.cochat.ai/papers/10.1016/j.enconman.2021.114494
The paper
Yu, H., Helland, H., Yu, X., Gundersen, T., & Sin, G. (2021). Optimal design and operation of an Organic Rankine Cycle (ORC) system driven by solar energy with sensible thermal energy storage. Energy Conversion and Management. https://doi.org/10.1016/j.enconman.2021.114494

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.