Cited by 53Refrigeration and Air Conditioning TechnologiesGeothermal Energy Systems and ApplicationsHeat Transfer and Boiling Studies

The DOI matches its Crossref record.

An experimental comparison of two heat exchangers used in wastewater source heat pump: A novel dry-expansion shell-and-tube evaporator versus a conventional immersed evaporator

Overview

Integrity signals

Registry

Crossref · 10.1016/j.energy.2012.09.043

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 17

  1. Büyükalaca, 2003, Experimental investigation of Seyhan River and Dam Lake as heat source-sink for a heat pump, Energy, 28, 157, 10.1016/S0360-5442(02)00088-9 · DOI
  2. Roy, 2010, Parametric optimization and performance analysis of a waste heat recovery system using Organic Rankine Cycle, Energy, 35, 5049, 10.1016/j.energy.2010.08.013 · DOI
  3. Bakirci, 2011, Energy analysis of a solar-ground source heat pump system with vertical closed-loop for heating applications, Energy, 36, 3224, 10.1016/j.energy.2011.03.011 · DOI
  4. Liu, 2010, Application of an exhaust heat recovery system for domestic hot water, Energy, 35, 1476, 10.1016/j.energy.2009.12.004 · DOI
  5. Zhao, 2010, Study of the performance of an urban original source heat pump system, Energy Conversion and Management, 51, 765, 10.1016/j.enconman.2009.10.033 · DOI
  6. Tassou, 1988, Heat recovery from sewage effluent using heat pumps, Heat Recovery System and CHP, 8, 141, 10.1016/0890-4332(88)90006-3 · DOI
  7. Baek, 2005, A study on the design and analysis of a heat pump heating system using wastewater as a heat source, Solar Energy, 78, 427, 10.1016/j.solener.2004.07.009 · DOI
  8. Yoshii, 2001, Technology for utilizing unused low temperature difference energy, Journal of the Japan Institute of Energy, 80, 696
  9. Funamizu, 2001, Reuse of heat energy in waste water: implementation examples in Japan, Water Science Technology, 43, 277, 10.2166/wst.2001.0640 · DOI
  10. Zan, 2009, Effects of temperature and velocity on fouling by municipal secondary effluent in plate heat exchangers (in Chinese), Journal of Tsinghua University (Science and Technology), 49, 240
  11. Lindstrom, 1985, Experiences with a 3.3 MW heat pump using sewage water as heat source, Heat Recovery Systems, 5, 33, 10.1016/0198-7593(85)90119-5 · DOI
  12. Yao, 2006, Simulation and analysis of sewage-source heat pump for low temperature wastewater treatment (in Chinese), China Water and Wastewater, 22, 70
  13. Qian, 2009, Analysis on heating performance of direct and indirect sewage source heat pump system (in Chinese), Journal of Hunan University (Natural Sciences), 36, 94
  14. Moffat, 1988, Describing the experimental uncertainties in experimental results, Experimental Thermal and Fluid Science, 1, 3, 10.1016/0894-1777(88)90043-X · DOI · Paper page
  15. Sun, 2010, Analysis of China's sewage resource heat utilization potential, China Water and Wastewater, 36, 210
  16. Shen, 2012, Experimental performance evaluation of a novel dry-expansion evaporator with defouling function in a wastewater source heat pump, Applied Energy, 95, 202, 10.1016/j.apenergy.2012.02.030 · DOI
  17. Xiao, 2007, The research on removing fouling methods of the heat exchanger of sewage heat pump system (in Chinese), Energy Conservation Technology, 25, 525

Metadata

Authors
Shen, C., Jiang, Y., Yao, Y., & Wang, X.
Affiliations
  • Harbin Institute of Technology (CN)
  • University of Illinois Urbana-Champaign (US)
Corresponding author
Jiang, Yiqiang
Venue
Energy
Publisher
Elsevier BV
Published
2012-11
Volume
47
Issue
1
Pages
600-608
ISSN
0360-5442 (ISSN-L)
OpenAlex
W1988393812
Cited by
53
References
0
Citations by year
2026: 4 · 2025: 3 · 2023: 5 · 2022: 3 · 2021: 5 · 2020: 6 · 2019: 6 · 2018: 6 · 2017: 4 · 2016: 3 · 2015: 3 · 2014: 4 · 2013: 1
FWCI
3.92
Type
journal article
Language
en
Open access
closed
Locations
  • Energy (publishedVersion)
  • RePEc: Research Papers in Economics (submittedVersion)
Funders
  • National Key Technology R&D Program in the 11th Five Year Plan of China (2006BAJ01A06)
  • University of Illinois at Urbana-Champaign
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Geothermal Energy Systems and Applications
  • Physical Sciences › Engineering › Mechanical Engineering › Heat Transfer and Boiling Studies
Keywords
coefficient of performance, heat transfer coefficient, compact heat exchangers, odor control

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review