Automated load pattern learning and anomaly detection for enhancing energy management in smart buildings
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The energy management of buildings currently offers a powerful opportunity to enhance energy efficiency and reduce the mismatch between the actual and expected energy demand, which is often due to an anomalous operation of the equipment and control systems. In this context, the characterisation of energy consumption patterns over time is of fundamental importance. This paper proposes a novel methodology for the characterisation of energy time series in buildings and the identification of infrequent and unexpected energy patterns. The process is based on an enhanced Symbolic Aggregate approXimation (SAX) process, and it includes an optimised tuning of the time window width and of the symbol intervals according to the building energy behaviour. The methodology has been tested on the whole electrical load of buildings for two case studies, and its flexibility and robustness have been confirmed. In order to demonstrate the implications for a preliminary diagnosis, some unexpected trends of the total electrical load have also been discussed in a post-mining phase, using additional datasets related to heating and cooling electrical energy needs. The process can be used to support stakeholders in characterising building behaviour, to define appropriate energy management strategies, and to send timely alerts based on anomaly detection outcomes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Occupancy schedules learning process through a data mining framework
D’Oca, S., & Hong, T. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2014.11.065 · Cited by 294
A review of electric load classification in smart grid environment
Zhou, K.-L., Yang, S.-L., & Shen, C. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.03.023 · Cited by 254
Cited by
Himeur, Y., Ghanem, K., Alsalemi, A., Bensaali, F., & Amira, A. (2021) · Applied Energy · doi:10.1016/j.apenergy.2021.116601 · Cited by 660
“While in [173], a graphical visualization tool for supporting the detection and diagnosis of power consumption abnormalities using a rule-based approach is proposed.”
MethodDeep Learning for Anomaly Detection in Time-Series Data: Review, Analysis, and Guidelines
Choi, K., Yi, J., Park, C., & Yoon, S. (2021) · IEEE Access · doi:10.1109/access.2021.3107975 · Cited by 588
Mariano-Hernández, D., Hernández-Callejo, L., Zorita-Lamadrid, A., Duque-Pérez, O., & Santos García, F. (2021) · Journal of Building Engineering · doi:10.1016/j.jobe.2020.101692 · Cited by 484
State-of-the-art on research and applications of machine learning in the building life cycle
Hong, T., Wang, Z., Luo, X., & Zhang, W. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109831 · Cited by 333
A review of data-driven fault detection and diagnostics for building HVAC systems
Chen, Z., O’Neill, Z., Wen, J., Pradhan, O., Yang, T., Lu, X., Lin, G., Miyata, S., Lee, S., Shen, C., et al. (2023) · Applied Energy · doi:10.1016/j.apenergy.2023.121030 · Cited by 311
Self-citation
Metadata
- Authors
- Capozzoli, A., Piscitelli, M. S., Brandi, S., Grassi, D., & Chicco, G.
- Venue
- Energy
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 157
- Pages
- 336-352
- ISSN
- 0360-5442 (ISSN-L)
- OpenAlex
- W2803203130
- Cited by
- 153
- References
- 2
- FWCI
- 11.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.