Finite element modeling of reinforced concrete beams exposed to fire
Open accessThe DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hillerborg, A., Modéer, M., & Petersson, P.-E. (1976) · Cement and Concrete Research · doi:10.1016/0008-8846(76)90007-7 · Cited by 6,874 · cited 2×
“[51] Hillerborg A, Modeer M, Petersson PE.”
BackgroundA plastic-damage model for concrete
Lubliner, J., Oliver, J., Oller, S., & Oñate, E. (1989) · International Journal of Solids and Structures · doi:10.1016/0020-7683(89)90050-4 · Cited by 4,396 · cited 2×
“[45] Lubliner J, Oliver J, Oller S, Onate E.”
Plastic-Damage Model for Cyclic Loading of Concrete Structures
Lee, J., & Fenves, G. L. (1998) · Journal of Engineering Mechanics · doi:10.1061/(asce)0733-9399(1998)124:8(892 · Cited by 4,018 · cited 2×
“[45] and later modified by Lee and Fenves [46] to reflect the different responses of concrete in tension and compression.”
Fracture and Size Effect in Concrete and Other Quasibrittle Materials
Bažant, Z. P., & Planas, J. (2019) · Routledge eBooks · doi:10.1201/9780203756799 · Cited by 2,636 · cited 1×
“In a smeared crack model, the predicted strain of cracked concrete depends on the element size [50].”
Design in structural steelwork to BS 5950
(2009) · Design of Structural Elements · doi:10.1201/b18121-13 · Cited by 1,243
Structural Design for Fire Safety
Buchanan, A. H., & Abu, A. K. (2016) · doi:10.1002/9781118700402 · Cited by 929 · cited 1×
“Decomposition of strain The total strain of concrete at elevated temperatures includes four parts: the free thermal strain, the instantaneous stress-induced strain, the classical creep strain, and the transient creep strain [62-65], as shown in the following expression: , , , , t ot th cr t r T T T t T…”
Eurocode 2: Design of concrete structures
(2009) · Design of Structural Elements · doi:10.1201/b18121-18 · Cited by 831
Effect of fire on concrete and concrete structures
Khoury, G. A. (2000) · Progress in Structural Engineering and Materials · doi:10.1002/pse.51 · Cited by 802 · cited 1×
“Moreover, previous tests showed that concrete spalling occurs during the first 20-60 minutes in a fire [93].”
Fire dynamics simulator (version 2): technical reference guide
McGrattan, K. B., Baum, H. R., Rehm, R. G., Hamins, A., Forney, G. P., Floyd, J. E., Hostikka, S., & Prasad, K. (2002) · doi:10.6028/nist.ir.6783e2002 · Cited by 563
Structural design for fire safety
Milke, J. (2002) · Fire Safety Journal · doi:10.1016/s0379-7112(02)00022-x · Cited by 407
Committee on Fire Protection (1992) · American Society of Civil Engineers eBooks · doi:10.1061/9780872628885 · Cited by 308
Fire Safety Engineering Design of Structures
Purkiss, J. A. (2007) · CRC Press eBooks · doi:10.1201/b12845 · Cited by 211
Cadorin, J.-F., & Franssen, J. M. (2003) · Fire Safety Journal · doi:10.1016/s0379-7112(03)00014-6 · Cited by 138 · cited 1×
“The two-zone fire model (based on the division of a given compartment into a top hot-layer and a bottom cold-layer) has been implemented into several free programs, such as Ozone (developed at the University of Liege, Belgium [83]) and CFAST (developed at the National Institute of Standard and Technology (NIST), Unite…”
Performance-based Fire Safety Design of Reinforced Concrete Beams
Kodur, V. K. R., & Dwaikat, M. (2007) · Journal of Fire Protection Engineering · doi:10.1177/1042391507077198 · Cited by 109 · cited 3×
“The mechanical response of RC beams is evaluated using either the traditional sectional analysis [8,18,21,22,24,26,27] or the FE method; in the latter case, beam elements [17-20,25,29-31] or isoparametric four-node quadrilateral elements [32] have both been employed.”
High-Temperature Properties of Concrete for Fire Resistance Modeling of Structures
Kodur, V. K. R., Dwaikat, M., & Dwaikat, M. (2008) · ACI Materials Journal · doi:10.14359/19982 · Cited by 97
Macroscopic FE model for tracing the fire response of reinforced concrete structures
Kodur, V. K. R., Dwaikat, M. B., & Raut, N. (2009) · Engineering Structures · doi:10.1016/j.engstruct.2009.05.018 · Cited by 85 · cited 2×
“The mechanical response of RC beams is evaluated using either the traditional sectional analysis [8,18,21,22,24,26,27] or the FE method; in the latter case, beam elements [17-20,25,29-31] or isoparametric four-node quadrilateral elements [32] have both been employed.”
Choi, E. G., & Shin, Y.-S. (2011) · Engineering Structures · doi:10.1016/j.engstruct.2010.12.030 · Cited by 82 · cited 1×
“11f, the spalling zones observed in the fire tests of HSC beams [94,95] are almost identical to the compressive stress zones predicted by the FE model (Figs.”
Tang, W., & Lo, T. Y. (2009) · Magazine of Concrete Research · doi:10.1680/macr.2008.00084 · Cited by 66 · cited 2×
“Existing tests on the fracture energy of concrete at elevated temperatures were conducted using different test methods and different types of test specimens [54-59].”
Rafi, M. M., Nadjai, A., & Ali, F. (2008) · ACI Structural Journal · doi:10.14359/20098 · Cited by 55
Cellular Finite Beam Element for Nonlinear Analysis of Concrete Structures under Fire
Biondini, F., & Nero, A. (2010) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0000307 · Cited by 32 · cited 1×
“It is noted that the uniaxial compressive stress-strain relationship provided by the EN 1992-1-2 [14] has implicitly incorporated the effect of transient creep as pointed out in previous studies [65,67,68]; furthermore, transient creep exists for concrete in compression rather than in tension.”
Metadata
- Authors
- Gao, W. Y., Dai, J.-G., Teng, J. G., & Chen, G. M.
- Venue
- Engineering Structures
- Publisher
- Elsevier BV
- Published
- 2013-07
- Volume
- 52
- Pages
- 488-501
- ISSN
- 0141-0296 (ISSN-L)
- OpenAlex
- W1978462351
- Cited by
- 179
- References
- 20
- FWCI
- 15.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.