The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Calibration of low-cost particulate matter sensors: Model development for a multi-city epidemiological study
Open accessAbstract
Low-cost air monitoring sensors are an appealing tool for assessing pollutants in environmental studies. Portable low-cost sensors hold promise to expand temporal and spatial coverage of air quality information. However, researchers have reported challenges in these sensors′ operational quality. We evaluated the performance characteristics of two widely used sensors, the Plantower PMS A003 and Shinyei PPD42NS, for measuring fine particulate matter compared to reference methods, and developed regional calibration models for the Los Angeles, Chicago, New York, Baltimore, Minneapolis-St. Paul, Winston-Salem and Seattle metropolitan areas. Duplicate Plantower PMS A003 sensors demonstrated a high level of precision (averaged Pearson′s r = 0.99), and compared with regulatory instruments, showed good accuracy (cross-validated R2 = 0.96, RMSE = 1.15 µg/m3 for daily averaged PM2.5 estimates in the Seattle region). Shinyei PPD42NS sensor results had lower precision (Pearson′s r = 0.84) and accuracy (cross-validated R2 = 0.40, RMSE = 4.49 µg/m3). Region-specific Plantower PMS A003 models, calibrated with regulatory instruments and adjusted for temperature and relative humidity, demonstrated acceptable performance metrics for daily average measurements in the other six regions (R2 = 0.74–0.95, RMSE = 2.46–0.84 µg/m3). Applying the Seattle model to the other regions resulted in decreased performance (R2 = 0.67–0.84, RMSE = 3.41–1.67 µg/m3), likely due to differences in meteorological conditions and particle sources. We describe an approach to metropolitan region-specific calibration models for low-cost sensors that can be used with caution for exposure measurement in epidemiological studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cross‐validation strategies for data with temporal, spatial, hierarchical, or phylogenetic structure
Roberts, D. R., Bahn, V., Ciuti, S., Boyce, M. S., Elith, J., Guillera‐Arroita, G., Hauenstein, S., Lahoz‐Monfort, J. J., Schröder, B., Thuiller, W., et al. (2017) · Ecography · doi:10.1111/ecog.02881 · Cited by 3,689
Cited by
Giordano, M. R., Malings, C., Pandis, S. N., Presto, A. A., McNeill, V. F., Westervelt, D. M., Beekmann, M., & Subramanian, R. (2021) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2021.105833 · Cited by 426
Barkjohn, K. K., Gantt, B., & Clements, A. L. (2021) · Atmospheric Measurement Techniques · doi:10.5194/amt-14-4617-2021 · Cited by 392
3D-printed sensors: Current progress and future challenges
Khosravani, M. R., & Reinicke, T. (2020) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2020.111916 · Cited by 331
Metadata
- Authors
- Zusman, M., Schumacher, C. S., Gassett, A. J., Spalt, E. W., Austin, E., Larson, T. V., Carvlin, G., Seto, E., Kaufman, J. D., & Sheppard, L.
- Venue
- Environment International
- Publisher
- Elsevier BV
- Published
- 2020-01
- Volume
- 134
- Pages
- 105329
- ISSN
- 0160-4120 (ISSN-L)
- OpenAlex
- W2989951998
- Cited by
- 162
- References
- 1
- FWCI
- 6.94
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of low-cost particulate matter sensors: Model development for a multi-city epidemiological study. https://app.cochat.ai/papers/10.1016/j.envint.2019.105329
- The paper
- Zusman, M., Schumacher, C. S., Gassett, A. J., Spalt, E. W., Austin, E., Larson, T. V., Carvlin, G., Seto, E., Kaufman, J. D., & Sheppard, L. (2020). Calibration of low-cost particulate matter sensors: Model development for a multi-city epidemiological study. Environment International. https://doi.org/10.1016/j.envint.2019.105329
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.