The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Comparison of impedance based fault location methods for power distribution systems
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding power quality problems: voltage sags and interruptions
(2000) · Choice Reviews Online · doi:10.5860/choice.37-4522 · Cited by 1,791
Analysis of Faulted Power Systems
Anderson, P. M. (2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544129 · Cited by 586
Understanding Power Quality Problems, Voltage Sags and Interruptions
Bollen, M. (2000) · CERN Document Server (European Organization for Nuclear Research) · Cited by 467
Analysis of faulted power systems,
Magnusson, P. C. (1974) · Journal of the Franklin Institute · doi:10.1016/0016-0032(74)90099-4 · Cited by 411
Sachdev, M. S., & Agarwal, R. (1988) · IEEE Transactions on Power Delivery · doi:10.1109/61.4237 · Cited by 235
A fault location technique for rural distribution feeders
Girgis, A. A., Fallon, C. M., & Lubkeman, D. L. (1993) · IEEE Transactions on Industry Applications · doi:10.1109/28.259729 · Cited by 194
A fault location technique for rural distribution feeders
Girgis, A. A., Fallon, C. M., & Lubkeman, D. L. (2002) · [Proceedings] 1991 Rural Electric Power Conference. Papers presented at the 35th Annual Conference · doi:10.1109/repcon.1991.153081 · Cited by 188
Takagi, T., Yamakoshi, Y., Baba, J., et al. (1981) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1981.316604 · Cited by 139
A New Fault Location Algorithm for Radial Transmission Lines with Loads
Srinivasan, K., & St-Jacques, A. (1989) · IEEE Power Engineering Review · doi:10.1109/mper.1989.4310803 · Cited by 112
A new fault location algorithm for radial transmission lines with loads
Srinivasan, K., & St.-Jacques, A. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.32658 · Cited by 94
Cited by
Gururajapathy, S. S., Mokhlis, H., & Illias, H. A. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.021 · Cited by 360
Impedance-based fault location in transmission networks: theory and application
Das, S., Santoso, S., Gaikwad, A., & Patel, M. (2014) · IEEE Access · doi:10.1109/access.2014.2323353 · Cited by 254
Multiagent-Based Distribution Automation Solution for Self-Healing Grids
Eriksson, M., Armendariz, M., Vasilenko, O. O., Saleem, A., & Nordström, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2387098 · Cited by 149
A Comparative Review of Fault Location/Identification Methods in Distribution Networks
Haleem, A. M. I., Sharma, M., Sajan, K. S., & Babu, K. N. D. (2018) · 2018 1st International Conference on Advanced Research in Engineering Sciences (ARES) · doi:10.1109/aresx.2018.8723300 · Cited by 14
Metadata
- Authors
- Mora-Flòrez, J., Meléndez, J., & Carrillo-Caicedo, G.
- Venue
- Electric Power Systems Research
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 78
- Issue
- 4
- Pages
- 657-666
- ISSN
- 0378-7796 (ISSN-L)
- OpenAlex
- W1989834522
- Cited by
- 286
- References
- 12
- FWCI
- 19.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of impedance based fault location methods for power distribution systems. https://app.cochat.ai/papers/10.1016/j.epsr.2007.05.010
- The paper
- Mora-Flòrez, J., Meléndez, J., & Carrillo-Caicedo, G. (2008). Comparison of impedance based fault location methods for power distribution systems. Electric Power Systems Research. https://doi.org/10.1016/j.epsr.2007.05.010
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.