On the impact of different voltage unbalance metrics in distribution system optimization
Open accessThe claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The proposed hybrid PSOS-CGSA method finds better solutions for the OAPD problem, providing lower costs in each of 10 scenarios compared to PSO, GSA, PSOS and CGSA algorithms.
“It is clear that the proposed hybrid PSOS-CGSA method finds better solutions for the OAPD problem, i.e., provides lower costs in each of 10 scenarios compared to PSO, GSA, PSOS and CGSA algorithms.”
From Dynamic Optimal Power Dispatch in Unbalanced Distribution Networks with Single-Phase Solar PV Units and BESS (2023) · cites this paper as [24]
The Simulation Results (p. 6) describe three-phase optimal power flow solved with Ipopt on two test feeders, not an OAPD comparison. Searches for PSOS-CGSA, OAPD, the four comparator algorithms, and costs across ten scenarios found no passage addressing the claim in our copy. (LLM, conf=0.78)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
No references could be resolved yet.
Research works printed but not linked: 22
- [1][1] M. Karimi, H. Mokhlis, K. Naidu, S. Uddin, and A. Bakar, 'Photovoltaic penetration issues and impacts in distribution network-a review,' Renewable and Sustainable Energy Reviews , vol. 53, pp. 594-605, 2016. -
- [2][2] E. Muljadi, R. Schiferl, and T. A. Lipo, 'Induction machine phase balancing by unsymmetrical thyristor voltage control,' IEEE Trans. on Industry Applications , no. 3, pp. 669-678, 1985. -
- [3][3] N. C. Woolley and J. V. Milanovic, 'Statistical estimation of the source and level of voltage unbalance in distribution networks,' IEEE Trans. on Power Delivery , vol. 27, no. 3, pp. 1450-1460, 2012. -
- [6][6] 'IEEE Recommended Practice for Electric Power Distribution for Industrial Plants,' IEEE Standard 141-1993 , pp. 1-768, April 1994. -
- [7][7] P. Pillay and M. Manyage, 'Definitions of voltage unbalance,' IEEE Power Engineering Review , vol. 21, no. 5, pp. 50-51, 2001. -
- [8][8] F. Shahnia, P. J. Wolfs, and A. Ghosh, 'Voltage unbalance reduction in low voltage feeders by dynamic switching of residential customers among three phases,' IEEE Transactions on Smart Grid , vol. 5, no. 3, pp. 1318-1327, 2014. -
- [9][9] Y. Xu, L. M. Tolbert, J. D. Kueck, and D. T. Rizy, 'Voltage and current unbalance compensation using a static var compensator,' IET Power Electronics , vol. 3, no. 6, pp. 977-988, 2010. -
- [10][10] X. Liu, A. Aichhorn, L. Liu, and H. Li, 'Coordinated control of distributed energy storage system with tap changer transformers for voltage rise mitigation under high photovoltaic penetration,' IEEE Transactions on Smart Grid , vol. 3, no. 2, pp. 897-906, 2012. -
- [11][11] X. Su, M. A. Masoum, and P. J. Wolfs, 'Optimal pv inverter reactive power control and real power curtailment to improve performance of unbalanced four-wire lv distribution networks,' IEEE Transactions on Sustainable Energy , vol. 5, no. 3, pp. 967-977, 2014. -
- [12][12] S. Weckx, C. Gonzalez, and J. Driesen, 'Reducing grid losses and voltage unbalance with pv inverters,' in 2014 IEEE PES General Meeting- Conference & Exposition . IEEE, 2014, pp. 1-5. -
- [13][13] S. Karagiannopoulos, P. Aristidou, and G. Hug, 'A centralised control method for tackling unbalances in active distribution grids,' in 2018 Power Systems Computation Conference (PSCC) , 2018. -
- [14][14] K. Schneider, B. Mather, B. Pal, C.-W. Ten, G. Shirek, H. Zhu, J. Fuller, J. Pereira, L. Ochoa, L. De Araujo et al. , 'Analytic considerations and design basis for the ieee distribution test feeders,' IEEE Transactions on Power Systems , vol. 33, no. 3, pp. 3181-3188, 2017. -
- [15][15] C. G. Bajo, S. Hashemi, S. B. Kjsær, G. Yang, and J. Østergaard, 'Voltage unbalance mitigation in lv networks using three-phase pv systems,' in Industrial Technology (ICIT), 2015 IEEE International Conference on . IEEE, 2015, pp. 2875-2879. -
- [16][16] J.-G. Kim, E.-W. Lee, D.-J. Lee, and J.-H. Lee, 'Comparison of voltage unbalance factor by line and phase voltage,' in Eighth International Conference on Electrical Machines and Systems (ICEMS) , vol. 3, 2005, pp. 1998-2001. -
- [17][17] K. Girigoudar, D. Molzahn, and L. Roald, 'On the relationships among different voltage unbalance definitions,' in North American Power Symposium (NAPS) . IEEE, 2019. -
- [20][20] M. Bazrafshan and N. Gatsis, 'Comprehensive modeling of three-phase distribution systems via the bus admittance matrix,' IEEE Transactions on Power Systems , vol. 33, no. 2, pp. 2015-2029, 2018. -
- [21][21] W. H. Kersting, Distribution system modeling and analysis . CRC press, 2006. -
- [22][22] J. A. Arrillaga and B. Harker, Computer modelling of electrical power systems . John Wiley & Sons, Inc., 1983. -
- [23][23] Z. Wang, D. S. Kirschen, and B. Zhang, 'Accurate semidefinite programming models for optimal power flow in distribution systems,' arXiv preprint arXiv:1711.07853 , 2017. - · arXiv
- [24][24] J. Bezanson, A. Edelman, S. Karpinski, and V. Shah, 'Julia: A fresh approach to numerical computing,' SIAM Review , vol. 59, no. 1, pp. 65-98, 2017. [Online]. Available: https://doi.org/10.1137/141000671 - · DOI
- [25][25] I. Dunning, J. Huchette, and M. Lubin, 'Jump: A modeling language for mathematical optimization,' SIAM Review , vol. 59, no. 2, pp. 295-320, 2017. -
- [26][26] A. W¨ achter and L. T. Biegler, 'On the implementation of a primaldual interior point filter line search algorithm for large-scale nonlinear programming,' Math. Programming , vol. 106, no. 1, pp. 25-57, 2006. -
Cited by
Sorted by citations
Radosavljević, J., Ktena, A., Gajić, M., Milovanović, M., & Živić, J. (2023) · Energies · doi:10.3390/en16114356 · Cited by 10 · see citing works
- Authors
- Girigoudar, K., & Roald, L. A.
- Affiliations
- University of Wisconsin–Madison (US)
- Corresponding author
- Girigoudar, Kshitij
- Venue
- Electric Power Systems Research
- Publisher
- Elsevier BV
- Published
- 2020-12
- Volume
- 189
- Pages
- 106656
- ISSN
- 0378-7796 (ISSN-L)
- OpenAlex
- W3018083143
- Cited by
- 68
- References
- 0
- Citations by year
- 2026: 9 · 2025: 11 · 2024: 9 · 2023: 15 · 2022: 12 · 2021: 10 · 2020: 2
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Electric Power Systems Research (acceptedVersion)
- arXiv (Cornell University) (submittedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- arXiv (Cornell University)
- Funders
- U.S. Department of Energy
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Keywords
- voltage unbalance, distribution network optimization, optimal power flow, reactive power support, power quality standards, IEC 61000-4-30, network losses, low-voltage distribution networks, three-phase unbalanced loads
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review