The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
A Review of Phase Change Materials for the Thermal Management and Isothermalisation of Lithium-Ion Cells
Abstract
Abstract Li-Ion batteries will play an important role in reaching emission targets by sustaining the further integration of renewable energy technologies and Electric Vehicles (EVs) in society. Their performance however is quite sensitive to temperature, leading to capacity fade, acceleration of ageing effect and possible thermal runaway. A Thermal Management System (TMS) should maintain a battery at an operating temperature within an optimal range and maximise temperature uniformity, i.e. approaching an isothermal condition. Many studies have experimentally investigated the electrical performance of Li-Ion batteries under controlled environmental temperatures. Notably however, these controlled conditions do not impose a uniform temperature or a controlled rate of cooling, as a TMS would. From a review of the relevant literature a ratio of the heat generation to the power production is proposed, i.e. quantifying an equivalent electro-chemical efficiency to advance research in this technological area and as additional TMS design metric. Overall, there is enough evidence that 25–30 °C is the best temperature range to minimise the ageing effect while 25–40 °C is typically reported as the general Li-Ion cells operating range. No specific temperature is identified to optimise the cycle electro-chemical efficiency and minimise the ageing effect. Therefore, a TMS should keep Li-Ion batteries within a specific temperature range according to the need for either higher electro-chemical efficiencies (i.e. higher powers and lower heat generation rates) or higher operating life. There are four main thermal management approaches of Li-Ion batteries: air-cooling, liquid-cooling, boiling and Phase Change Materials (PCM). Air cooling is preferred for safety reasons but is less efficient as the rate of heat transfer achievable is relatively low. Forced air cooling can effectively keep the temperature at a preferred level but fails to guarantee a uniform temperature. Liquid cooling is better in terms of heat transfer performance, but it is less safe and can still result in significant thermal gradients within the pack. Boiling effectively keeps Li-Ion cells temperature constant and uniform but can be quite complex to operate and control. Phase Change Materials (PCMs) as a passive cooling approach are proposed as an effective and low-cost isothermalisation technique. However, when Li-Ion batteries are operated under extreme conditions (high ambient temperature, high discharge rates), PCM are not able to recover all latent energy potential during solidification and this leads to possible thermal runaway. Overall, it is clear that no TMS alone is holistically better than others and the choice between air cooling, liquid cooling, boiling and latent heat PCM systems is entirely linked to the specific combination of temperatures, heat rates, cells capacity and geometry. Active PCM systems however, mainly a combination of liquid cooling and passive PCM, show promising results towards an ideal isothermal condition. Also, they introduce the potential to store the thermal energy and use it as needed, converting a Li-Ion cell from an Electrical Energy Storage System (EESS) to a Combined Heat and Power (CHP) system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapidly falling costs of battery packs for electric vehicles
Nykvist, B., & Nilsson, M. (2015) · Nature Climate Change · doi:10.1038/nclimate2564 · Cited by 1,819
Cited by
A review on thermal management of lithium-ion batteries for electric vehicles
Zhang, X., Li, Z., Luo, L., Fan, Y., & Du, Z. (2022) · Energy · doi:10.1016/j.energy.2021.121652 · Cited by 1,097
A review on recent progress, challenges and perspective of battery thermal management system
Lin, J., Liu, X., Li, S., Zhang, C., & Yang, S. (2021) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2020.120834 · Cited by 588
Heyhat, M. M., Mousavi, S., & Siavashi, M. (2020) · Journal of Energy Storage · doi:10.1016/j.est.2020.101235 · Cited by 527
Developments in battery thermal management systems for electric vehicles: A technical review
Tete, P. R., Gupta, M. M., & Joshi, S. S. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102255 · Cited by 388
Akbarzadeh, M., Jaguemont, J., Kalogiannis, T., Karimi, D., He, J., Jin, L., Xie, P., Van Mierlo, J., & Berecibar, M. (2021) · Energy Conversion and Management · doi:10.1016/j.enconman.2021.113862 · Cited by 336
Battery thermal management systems: Recent progress and challenges
Olabi, A. G., Maghrabie, H. M., Adhari, O. H. K., Sayed, E. T., Yousef, B. A. A., Salameh, T., Kamil, M., & Abdelkareem, M. A. (2022) · International Journal of Thermofluids · doi:10.1016/j.ijft.2022.100171 · Cited by 332
A comprehensive review on heat pipe based battery thermal management systems
Weragoda, D. M., Tian, G., Burkitbayev, A., Lo, K.-H., & Zhang, T. (2023) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2023.120070 · Cited by 330
Metadata
- Authors
- Landini, S., Leworthy, J., & O’Donovan, T. S.
- Venue
- Journal of Energy Storage
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 25
- Pages
- 100887
- ISSN
- 2352-152X (ISSN-L)
- OpenAlex
- W2969213688
- Cited by
- 177
- References
- 1
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.