The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The role of hydrogen in the optimal design of off-grid hybrid renewable energy systems
Open accessAbstract
The optimal design of off-grid hybrid renewable energy systems (HRESs) is a challenging task, which often involves conflicting goals to be faced. In this work, levelized cost of energy (LCOE) and CO2 emissions have been addressed simultaneously by using the ε-constraint method together with the particle swarm optimization (PSO) algorithm. Cost-emissions Pareto fronts of different HRES configurations were developed to gain greater awareness about the potential of renewable-based energy systems in off-grid applications. Various combinations of the following components were investigated: photovoltaic panels, wind turbines, batteries, hydrogen and diesel generators. The hydrogen-based system comprises an electrolyzer to convert the excess renewable energy into hydrogen, a pressurized tank for H2 storage and a fuel cell for the reconversion of hydrogen into electricity during renewable energy deficits. Electrolyzer and fuel cell devices were modelled by means of part-load performance curves. Size-dependent costs and component lifetimes as a function of the cumulative operational duty were also considered for a more accurate techno-economic assessment. The proposed methodology was applied to the Froan islands (Norway), which were chosen as a reference case study since they are well representative of many other insular microgrid environments in Northern Europe. Results from the sizing simulations revealed that energy storage devices are key components to reduce the dependency on fossil fuels. In particular, the hydrogen storage system is crucial in off-grid areas to enhance the RES penetration and avoid a sharp increase in the cost of energy. Hydrogen, in fact, allows the battery and RES technologies not to be oversized, thanks to its cost-effective long-term storage capability. Concerning the extreme case with no diesel, the cheapest configuration, which includes both batteries and hydrogen, has an LCOE of 0.41 €/kWh. This value is around 35% lower than the LCOE of a system with only batteries as energy storage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogen in energy transition: A review
Kovač, A., Paranos, M., & Marciuš, D. (2021) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2020.11.256 · Cited by 1,214
Seasonal storage and alternative carriers: A flexible hydrogen supply chain model
Reuß, M., Grube, T., Robinius, M., Preuster, P., Wasserscheid, P., & Stolten, D. (2017) · Applied Energy · doi:10.1016/j.apenergy.2017.05.050 · Cited by 722
Cited by
Prospects for the production of green hydrogen: Review of countries with high potential
Panchenko, V. A., Daus, Y. V., Kovalev, A. A., Yudaev, I. V., & Litti, Y. V. (2023) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2022.10.084 · Cited by 366
Metadata
- Authors
- Marocco, P., Ferrero, D., Lanzini, A., & Santarelli, M.
- Venue
- Journal of Energy Storage
- Publisher
- Elsevier BV
- Published
- 2022-02
- Volume
- 46
- Pages
- 103893
- ISSN
- 2352-152X (ISSN-L)
- OpenAlex
- W4205144296
- Cited by
- 207
- References
- 2
- FWCI
- 8.14
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The role of hydrogen in the optimal design of off-grid hybrid renewable energy systems. https://app.cochat.ai/papers/10.1016/j.est.2021.103893
- The paper
- Marocco, P., Ferrero, D., Lanzini, A., & Santarelli, M. (2022). The role of hydrogen in the optimal design of off-grid hybrid renewable energy systems. Journal of Energy Storage. https://doi.org/10.1016/j.est.2021.103893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.