The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Liver CT sequence segmentation based with improved U-Net and graph cut
Abstract
Abstract Liver segmentation has always been the focus of researchers because it plays an important role in medical diagnosis. However, under the condition of low contrast between a liver and surrounding organs and tissues, CT image noise and the large difference between the liver shapes of patients, existing liver image segmentation algorithms are difficult to obtain satisfactory results. To improve this situation, we propose a liver CT sequesnce image segmentation algorithm GIU-Net, which combines an improved U-Net neural network model with graph cutting. Specifically, we initially segment a liver from a liver CT sequence using an improved U-Net and obtain the probability distribution map of the liver regions. Secondly, the sequence segmentation start slice is selected, and then the context information of the liver sequence images and the liver probability distribution map are used to construct a graph cut energy function. Finally, the segmentation is done by minimizing the graph cut energy function. Our experimental results show that GIU-Net has a good performance when segmenting liver sequence images in terms of segmentation accuracy and robustness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
U-Net: Convolutional Networks for Biomedical Image Segmentation
Ronneberger, O., Fischer, P., & Brox, T. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-24574-4_28 · Cited by 99,404
Fast approximate energy minimization via graph cuts
Boykov, Y., Veksler, O., & Zabih, R. (2001) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.969114 · Cited by 6,988
Graph Cuts and Efficient N-D Image Segmentation
Boykov, Y., & Funka-Lea, G. (2006) · International Journal of Computer Vision · doi:10.1007/s11263-006-7934-5 · Cited by 1,910
3D Deeply Supervised Network for Automatic Liver Segmentation from CT Volumes
Dou, Q., Chen, H., Jin, Y., Yu, L., Qin, J., & Heng, P.-A. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_18 · Cited by 344
Automatic 3D liver location and segmentation via convolutional neural network and graph cut
Lu, F., Wu, F., Hu, P., Peng, Z., & Kong, D. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1467-3 · Cited by 284
Cited by
U-Net and Its Variants for Medical Image Segmentation: A Review of Theory and Applications
Siddique, N., Paheding, S., Elkin, C. P., & Devabhaktuni, V. (2021) · IEEE Access · doi:10.1109/access.2021.3086020 · Cited by 1,960
MA-Net: A Multi-Scale Attention Network for Liver and Tumor Segmentation
Fan, T., Wang, G., Li, Y., & Wang, H. (2020) · IEEE Access · doi:10.1109/access.2020.3025372 · Cited by 490
Metadata
- Authors
- Liu, Z., Song, Y.-Q., Sheng, V. S., Wang, L., Jiang, R., Zhang, X., & Yuan, D.
- Venue
- Expert Systems with Applications
- Publisher
- Elsevier BV
- Published
- 2019-07
- Volume
- 126
- Pages
- 54-63
- ISSN
- 0957-4174 (ISSN-L)
- OpenAlex
- W2913637767
- Cited by
- 161
- References
- 5
- FWCI
- 10.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Liver CT sequence segmentation based with improved U-Net and graph cut. https://app.cochat.ai/papers/10.1016/j.eswa.2019.01.055
- The paper
- Liu, Z., Song, Y.-Q., Sheng, V. S., Wang, L., Jiang, R., Zhang, X., & Yuan, D. (2019). Liver CT sequence segmentation based with improved U-Net and graph cut. Expert Systems with Applications. https://doi.org/10.1016/j.eswa.2019.01.055
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.