Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 193

The DOI matches its Crossref record.

Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement

Open access
Lickfett, L · 2004 · Europace

Abstract

AIMS: The number of implantable cardioverter defibrillator (ICD) implantations, as well as follow-up procedures such as generator exchanges, lead revisions and lead system upgrades, is ever-increasing. Lead revisions and implantation of additional leads require venous access at the site of the previous ICD implantation. The aim of our study was therefore to evaluate the incidence of venous obstruction after chronic transvenous ICD system implantation. METHODS AND RESULTS: One hundred and five consecutive patients admitted for their first elective ICD generator replacement were included. All patients underwent bilateral contrast venography and the images were analyzed by two attending radiologists. Venous obstruction was classified as moderate stenosis (50-75% diameter reduction), severe stenosis (>75%) or total occlusion. Venous obstruction of various degrees was found in 25% of the patients. Complete occlusion was found in 9%, severe stenosis in 6% and moderate stenosis in 10% of the patients. The incidence of venous obstruction was increased in patients with a pacemaker prior to the initial ICD system implantation (67%). No difference was found in patients with a single defibrillator lead compared with patients who had an additional superior vena cava (SVC) shocking coil. However, the presence of a second shocking coil in the SVC incorporated in a single ICD lead was associated with an increased incidence of venous obstruction. No difference was found between silicone and polyurethane insulated leads. CONCLUSION: This study shows that venous obstruction occurs relatively frequently after ICD implantation. Therefore, contrast venography should always be obtained if malfunction of a preexistent lead is suspected or a system upgrade is considered.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eupc.2003.09.001

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Lickfett, L.
Venue
Europace
Published
2004-01
Volume
6
Issue
1
Pages
25-31
ISSN
1099-5129 (ISSN-L)
OpenAlex
W2130343771
Cited by
193
References
0
FWCI
2.72
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement. https://app.cochat.ai/papers/10.1016/j.eupc.2003.09.001
The paper
Lickfett, L. (2004). Incidence of venous obstruction following insertion of an implantable cardioverter defibrillator. A study of systematic contrast venography on patients presenting for their first elective ICD generator replacement. Europace. https://doi.org/10.1016/j.eupc.2003.09.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.