The Living Heart Project: A robust and integrative simulator for human heart function
Open accessAbstract
The heart is not only our most vital, but also our most complex organ: Precisely controlled by the interplay of electrical and mechanical fields, it consists of four chambers and four valves, which act in concert to regulate its filling, ejection, and overall pump function. While numerous computational models exist to study either the electrical or the mechanical response of its individual chambers, the integrative electro-mechanical response of the whole heart remains poorly understood. Here we present a proof-of-concept simulator for a four-chamber human heart model created from computer topography and magnetic resonance images. We illustrate the governing equations of excitation-contraction coupling and discretize them using a single, unified finite element environment. To illustrate the basic features of our model, we visualize the electrical potential and the mechanical deformation across the human heart throughout its cardiac cycle. To compare our simulation against common metrics of cardiac function, we extract the pressure-volume relationship and show that it agrees well with clinical observations. Our prototype model allows us to explore and understand the key features, physics, and technologies to create an integrative, predictive model of the living human heart. Ultimately, our simulator will open opportunities to probe landscapes of clinical parameters, and guide device design and treatment planning in cardiac diseases such as stenosis, regurgitation, or prolapse of the aortic, pulmonary, tricuspid, or mitral valve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“showing that the biomechanics of these single-layer ventricle models is consistent with theoretical predictions from the past 50 years (3, 4, 25).”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [25]
Experimental — accuracy not yet measuredThe check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Overall, these results were consistent with the projections of previous analytical and computational models (3, 25, 36) in that they showed more-homogeneous deformations for HA ventricles.”
From Recreating the heart's helical structure-function relationship with focused rotary jet spinning (2022) · cites this paper as [25]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impulses and Physiological States in Theoretical Models of Nerve Membrane
Fitzhugh, R. (1961) · Biophysical Journal · doi:10.1016/s0006-3495(61)86902-6 · Cited by 6,199
Heart Disease and Stroke Statistics—2014 Update
Go, A. S., Mozaffarian, D., Roger, V. L., Benjamin, E. J., Berry, J. D., Blaha, M. J., Dai, S., Ford, E. S., Fox, C. S., Franco, S., et al. (2013) · Circulation · doi:10.1161/01.cir.0000441139.02102.80 · Cited by 5,264
An Active Pulse Transmission Line Simulating Nerve Axon
Nagumo, J., Arimoto, S., & Yoshizawa, S. (1962) · Proceedings of the IRE · doi:10.1109/jrproc.1962.288235 · Cited by 4,278
Heart Disease: A Textbook of Cardiovascular Medicine.
(1984) · Annals of Internal Medicine · doi:10.7326/0003-4819-101-3-415_3 · Cited by 4,119
Robbins and Cotran Pathologic Basis of Disease
Hoda, S. A., & Hoda, R. S. (2020) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqaa163 · Cited by 3,370
Nonlinear Solid Mechanics: A Continuum Approach for Engineering
Holzapfel, G. A. (2000) · Cited by 2,733
Keener, J. P., & Sneyd, J. (2009) · Interdisciplinary applied mathematics · doi:10.1007/978-0-387-75847-3 · Cited by 2,213
Nonlinear Continuum Mechanics for Finite Element Analysis
Bonet, J., & Wood, R. D. (2008) · doi:10.1017/cbo9780511755446 · Cited by 1,824
Robbins and Cotran Pathologic Basis of Disease
Hoda, S. A., & Hoda, R. S. (2005) · Advances in Anatomic Pathology · doi:10.1097/01.pap.0000155072.86944.7d · Cited by 1,566
Heart Disease: A Textbook of Cardiovascular Medicine
Zoneraich, S. (1997) · JAMA · doi:10.1001/jama.1997.03540390077042 · Cited by 1,074
Research works printed but not linked: 1
- 2014, Simulia, Dassault Systèmes
Cited by
Sorted by citations
Items 101–200 of 363
A pilot study of bladder voiding with real-time MRI and computational fluid dynamics
Pewowaruk, R. J., Rutkowski, D. R., Hernando, D., Kumapayi, B. B., BUSHMAN, W. A., & Roldán‐Alzate, A. (2020) · PLoS ONE · doi:10.1371/journal.pone.0238404 · Cited by 27
lifex-ep: a robust and efficient software for cardiac electrophysiology simulations
Africa, P. C., Piersanti, R., Regazzoni, F., Bucelli, M., Salvador, M., Fedele, M., Pagani, S., Dede’, L., & Quarteroni, A. M. (2023) · BMC Bioinformatics · doi:10.1186/s12859-023-05513-8 · Cited by 27
Dabiri, Y., Jiang, Y. D., Sack, K. L., Kassab, G. S., & Guccione, J. M. (2019) · Mechanics Research Communications · doi:10.1016/j.mechrescom.2019.04.009 · Cited by 26
Khodaei, S., Sadeghi, R., Blanke, P., Leipsic, J. A., Emadi, A., & Keshavarz‐Motamed, Z. (2021) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2021.106506 · Cited by 26
Park, M. H., Zhu, Y., Imbrie-Moore, A. M., Wang, H., Cuartas, M. M., Paulsen, M. J., & Woo, Y.-P. J. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.673689 · Cited by 26
Dassault Systèmes’ Living Heart Project
Levine, S., Battisti, T., Butz, B., D'Souza, K., Costabal, F. S., & Peirlinck, M. (2022) · Springer eBooks · doi:10.1007/978-3-030-88892-3_25 · Cited by 26
Predicting the cardiac toxicity of drugs using a novel multiscale exposure–response simulator
Costabal, F. S., Jiang, Y. D., & Ellen Kuhl, A. (2018) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2018.1439479 · Cited by 26
Rama, R. R., Skatulla, S., & Sansour, C. (2016) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2016.04.003 · Cited by 25
Numerical Simulations of MitraClip Placement: Clinical Implications
Kamakoti, R., Dabiri, Y., Wang, D. D., Guccione, J. M., & Kassab, G. S. (2019) · Scientific Reports · doi:10.1038/s41598-019-52342-y · Cited by 25
Digital Twins Use in Plastic Surgery: A Systematic Review
Seth, I., Lim, B., Lu, P. Y. J., Xie, Y., Cuomo, R., Ng, S., Rozen, W. M., & Sofiadellis, F. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13247861 · Cited by 24
Martonová, D., Alkassar, M., Seufert, J., Holz, D., Dương, M. T., Reischl, B., Friedrich, O., & Leyendecker, S. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104430 · Cited by 24
Obermeier, L., Vellguth, K., Schlief, A., Tautz, L., Bruening, J., Knosalla, C., Kühne, T., Solowjowa, N., & Goubergrits, L. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.828556 · Cited by 24
Molléro, R., Pennec, X., Delingette, H., Garny, A., Ayache, N., & Maxime Sermesant, B. (2017) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-017-0960-0 · Cited by 24
Dabiri, Y., Sack, K. L., Rebelo, N. M. R. S., Wang, P., Wang, Y., Choy, J. S., Kassab, G. S., & Guccione, J. M. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4044215 · Cited by 24
Self-citationComparison of three machine learning methods to estimate myocardial stiffness
Mehdi, R. R., Mendiola, E. A., Sears, A., Choudhary, G., Jacques Ohayon, A., Pettigrew, R. I., & Avazmohammadi, R. (2023) · Elsevier eBooks · doi:10.1016/b978-0-32-389967-3.00025-1 · Cited by 23
Active contraction of the cardiac ventricle and distortion of the microstructural architecture
Pezzuto, S., & Ambrosi, D. (2014) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2690 · Cited by 23
Incorporation of the Living Heart Model Into the 4-D XCAT Phantom for Cardiac Imaging Research
Segars, W. P., Veress, A. I., Sturgeon, G. M., & Samei, E. (2018) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2823060 · Cited by 23
A consensus statement on the use of digital twins in medicine
Iqbal, J. D., Krauthammer, M. O., Witt, C. M., Biller‐Andorno, N., & Christen, M. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01897-4 · Cited by 22
Fuse, Y., Murphy, S. N., Ikari, H., Takahashi, A., Fuse, K., & Kawakami, E. (2025) · Allergology International · doi:10.1016/j.alit.2025.06.005 · Cited by 25
A modular framework for implicit 3D–0D coupling in cardiac mechanics
Brown, A. L., Salvador, M., Shi, L. T., Pfaller, M. R., Hu, Z., Harold, K. E., Hsiai, T. K., Vedula, V., & Marsden, A. L. (2024) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2024.116764 · Cited by 22
Optimization Framework for Patient-Specific Cardiac Modeling
Mineroff, J., McCulloch, A., Krummen, D., Ganapathysubramanian, B., & Krishnamurthy, A. (2019) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-019-00428-z · Cited by 13
Biffi, B., Gritti, M., Grasso, A. E., Milano, E. G., Fontana, M., Alkareef, H., Davar, J., Jeetley, P., Whelan, C. J., Anderson, S., et al. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.09.020 · Cited by 22
A Neural Network Finite Element Approach for High Speed Cardiac Mechanics Simulations
Motiwale, S., Zhang, W., Feldmeier, R., & Sacks, M. S. (2024) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2024.117060 · Cited by 21
The status quo and future prospects of digital twins for healthcare
Li, T., Shen, Y., Li, Y., Zhang, Y., & Wu, S. (2024) · EngMedicine · doi:10.1016/j.engmed.2024.100042 · Cited by 21
Wisneski, A. D., Wang, Y., Deuse, T., Hill, A. C., Pasta, S., Sack, K. L., Jiang, Y. D., & Guccione, J. M. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.574211 · Cited by 21
Rosalia, L., Öztürk, Ç., Story, D. V., Horvath, M. A., & Roche, E. T. (2021) · Advanced Theory and Simulations · doi:10.1002/adts.202000216 · Cited by 21
Regazzoni, F., & Quarteroni, A. M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104641 · Cited by 21
Interpreting Activation Mapping of Atrial Fibrillation: A Hybrid Computational/Physiological Study
Costabal, F. S., Zaman, J. A. B., Ellen Kuhl, A., & Narayan, S. M. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1969-3 · Cited by 20
How drugs modulate the performance of the human heart
Peirlinck, M., Yao, J., Costabal, F. S., & Ellen Kuhl, A. (2022) · Computational Mechanics · doi:10.1007/s00466-022-02146-1 · Cited by 20
Pasta, S., Catalano, C., Cannata, S., Guccione, J. M., & Gandolfo, C. M. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111337 · Cited by 19
Baylous, K., Helbock, R. T., Kovarovic, B. J., Anam, S. B., Slepian, M. J., & Bluestein, D. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107886 · Cited by 19
Badrou, A., Mariano, C. A., Ramirez, G. O., Shankel, M., Rebelo, N. M. R. S., & Eskandari, M. (2025) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1012680 · Cited by 19
Self-citationSack, K. L., Skatulla, S., & Sansour, C. (2015) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2015.11.009 · Cited by 19
Multimodal cardiovascular model for hemodynamic analysis: Simulation study on mitral valve disorders
Roy, D., Mazumder, O., Sinha, A., & Khandelwal, S. (2021) · PLoS ONE · doi:10.1371/journal.pone.0247921 · Cited by 18
A new active contraction model for the myocardium using a modified hill model
Guan, D., Gao, H., Cai, L., & Luo, X. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105417 · Cited by 18
A stable loosely-coupled scheme for cardiac electro-fluid-structure interaction
Bucelli, M., Gabriel, M. G., Quarteroni, A. M., Gigante, G., & Vergara, C. (2023) · Journal of Computational Physics · doi:10.1016/j.jcp.2023.112326 · Cited by 18
Barros, M. T., Paci, M., Tervonen, A., Passini, E., Koivumäki, J. T., Hyttinen, J., & Lenk, K. (2024) · IEEE Transactions on Molecular Biological and Multi-Scale Communications · doi:10.1109/tmbmc.2024.3442083 · Cited by 18
Fan, L., Choy, J. S., Raissi, F., Kassab, G. S., & Lee, L. C. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.105050 · Cited by 18
Barbarotta, L., Rossi, S., Dede’, L., & Quarteroni, A. M. (2018) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3137 · Cited by 18
Erdemir, A., Guess, T. M., Halloran, J. P., Modenese, L., Reinbolt, J. A., Thelen, D. G., & Umberger, B. R. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2602760 · Cited by 18
Dabiri, Y., der Velden, A. V., Sack, K. L., Choy, J. S., Guccione, J. M., & Kassab, G. S. (2020) · Scientific Reports · doi:10.1038/s41598-020-79191-4 · Cited by 18
The role of computational methods in cardiovascular medicine: a narrative review
Fumagalli, I., Pagani, S., Vergara, C., Dede’, L., Adebo, D. A., Greco, M. D., Frontera, A., Luciani, G. B., Pontone, G., Scrofani, R., et al. (2024) · Translational Pediatrics · doi:10.21037/tp-23-184 · Cited by 17
Renal oxygenation: From data to insight
Gardiner, B. S., Smith, D. W., Lee, C. J., Ngo, J. P., & Evans, R. G. (2020) · Acta Physiologica · doi:10.1111/apha.13450 · Cited by 17
Harnessing cardiac power: Heart kinetic motion analysis for energy harvesters
Khazaee, M., Hasani, M., Riahi, S., Rosendahl, L. A., & Rezania, A. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106421 · Cited by 16
Palit, A., Franciosa, P., Bhudia, S. K., Arvanitis, T. N., Turley, G. A., & Williams, M. A. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.12.023 · Cited by 16
Hurtado, D. E., & Rojas, G. (2017) · Computational Mechanics · doi:10.1007/s00466-017-1473-5 · Cited by 16
Fan, Y., Ronan, W., Teh, I., Schneider, J. E., Varela, C. E., Whyte, W., McHugh, P. E., Leen, S. B., & Roche, E. T. (2019) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3213 · Cited by 16
AI‐Powered Multimodal Modeling of Personalized Hemodynamics in Aortic Stenosis
Öztürk, Ç., Pak, D. H., Rosalia, L., Goswami, D., Robakowski, M., McKay, R. G., Nguyen, C. T., Duncan, J. S., & Roche, E. T. (2024) · Advanced Science · doi:10.1002/advs.202404755 · Cited by 15
Canè, F., Verhegghe, B., Beule, M. D., Bertrand, P. B., van der Geest, R. J., Segers, P., & Santis, G. D. (2018) · BioMed Research International · doi:10.1155/2018/7030718 · Cited by 15
Young's Modulus and Load Complexity: Modeling Their Effects on Proximal Femur Strain
Sylvester, A. D., & Kramer, P. A. (2018) · The Anatomical Record · doi:10.1002/ar.23796 · Cited by 14
Molléro, R., Pennec, X., Delingette, H., Ayache, N., & Maxime Sermesant, B. (2018) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3158 · Cited by 14
Kügler, P. (2020) · Jahresbericht der Deutschen Mathematiker-Vereinigung · doi:10.1365/s13291-020-00218-w · Cited by 14
Kumar, V., Ryu, A. J., Manduca, A., Rao, C., Gibbons, R. J., Gersh, B. J., Chandrasekaran, K., Asirvatham, S. J., Araoz, P. A., Oh, J. K., et al. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.08.087 · Cited by 14
Patient-Specific Analysis of Ascending Thoracic Aortic Aneurysm with the Living Heart Human Model
Cutugno, S., Agnese, V., Gentile, G., Raffa, G. M., Wisneski, A. D., Guccione, J. M., Pilato, M., & Pasta, S. (2021) · Bioengineering · doi:10.3390/bioengineering8110175 · Cited by 14
A new computational framework for electro-activation in cardiac mechanics
Garcia-Blanco, E., Ortigosa, R., Gil, A. J., Lee, C. H., & Bonet, J. (2019) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.01.042 · Cited by 14
Cusumano, J. A., Kalogeropoulos, A. P., Provost, M. L., Gallo, N. R., Levine, S. M., Inzana, T. J., & Papamanoli, A. (2024) · Clinical Microbiology Reviews · doi:10.1128/cmr.00168-23 · Cited by 13
Sun, T., Lu, J., Li, Q., & Kou, Y. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1631339 · Cited by 13
Multiscale modeling of drug-induced liver injury from organ to lobule
Malka-Markovitz, A., Pinto, S. C. D., Cherkaoui, M., Levine, S. M., Anandasabapathy, S., Sood, G., Dhingra, S., Yujia, G., Vierling, J. M., & Gallo, N. R. (2025) · npj Digital Medicine · doi:10.1038/s41746-025-01736-6 · Cited by 15
Modeling the cardiac electromechanical function: A mathematical journey
Quarteroni, A. M., Dede’, L., & Regazzoni, F. (2022) · Bulletin of the American Mathematical Society · doi:10.1090/bull/1738 · Cited by 13
Stimm, J., Nordsletten, D., Jilberto, J., Miller, R., Berberoğlu, E., Kozerke, S., & Stoeck, C. T. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1042537 · Cited by 13
Towards real-time cardiac mechanics modelling with patient-specific heart anatomies
Rama, R. R., & Skatulla, S. (2017) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2017.08.015 · Cited by 12
Recapitulating Cardiac Structure and Function In Vitro from Simple to Complex Engineering
Santos, A. C., Jang, Y., Son, I., Kim, J., & Park, Y. (2021) · Micromachines · doi:10.3390/mi12040386 · Cited by 14
Personalized multiscale modeling of left atrial mechanics and blood flow
Shi, L. M., Gan, B., Chen, I. Y., & Vedula, V. (2025) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2025.118412 · Cited by 11
Torre, M., Morganti, S., Nitti, A., Tullio, M. D. D., Pasqualini, F. S., & Reali, A. (2023) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2023.116055 · Cited by 11
Digital Twin Technology - Fundamentals and Applications
Korhan, O. (2023) · Industrial engineering and management. · doi:10.5772/intechopen.104048 · Cited by 11
Electrothermal Equivalent Three-Dimensional Finite-Element Model of a Single Neuron
Cinelli, I., Michel Destrade, A., Duffy, M. C., & McHugh, P. E. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2752258 · Cited by 12
Öztürk, Ç., Rosalia, L., & Roche, E. T. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.815787 · Cited by 11
Dương, M. T., Holz, D., Alkassar, M., Dittrich, S., & Leyendecker, S. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01041 · Cited by 11
Reza, S., Kovarovic, B. J., & Bluestein, D. (2024) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-024-01893-9 · Cited by 10
Khazaee, M., Hasani, M., Enkeshafi, A. A., Riahi, S., Pedersen, K., & Rezania, A. (2025) · Smart Materials and Structures · doi:10.1088/1361-665x/adcfdc · Cited by 10
Choi, D.-K. (2016) · Biomedical Engineering Letters · doi:10.1007/s13534-016-0222-6 · Cited by 10
Zhang, Y., Adams, J., Wang, V. Y., Horwitz, L., Tartibi, M., Morgan, A. E., Kim, J. J., Wallace, A., Weinsaft, J., Ge, L., et al. (2021) · Comput. Biol. Medicine · doi:10.1016/j.compbiomed.2021.104840 · Cited by 8
Effects of dispersed fibres in myocardial mechanics, Part I: passive response
Guan, D., Mei, Y., Xu, L., Cai, L., Luo, X., & Gao, H. (2022) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2022183 · Cited by 10
Structural Responses of Integrated Parametric Aortic Valve in an Electro-Mechanical Full Heart Model
Morany, A., Lavon, K., Bluestein, D., Hamdan, A., & Haj-Ali, R. M. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02575-0 · Cited by 10
Towards the simulation of active cardiac mechanics using a smoothed finite element method
Martonová, D., Holz, D., Dương, M. T., & Leyendecker, S. (2020) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2020.110153 · Cited by 10
Richards, T. W., Sturgeon, G. M., Ramírez-Giraldo, J. C., Rubin, G. D., Koweek, L., Segars, W. P., & Samei, E. (2018) · Journal of medical imaging · doi:10.1117/1.jmi.5.1.013501 · Cited by 10
Costabal, F. S., Jiang, Y. D., Sher, A., & Ellen Kuhl, A. (2018) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2018.10.003 · Cited by 9
Jeong, B. C., Lee, C., Park, J. Y., & Ryu, D. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.969636 · Cited by 9
Perspective Chapter: Digital Twins for Health – Opportunities, Barriers and a Path Forward
Armeni, P., Polat, I., Rossi, L. M. D., Diaferia, L., Visioli, G., Meregalli, S., & Gatti, A. M. (2023) · Industrial engineering and management. · doi:10.5772/intechopen.112490 · Cited by 9
Discovering dispersion: How robust is automated model discovery for human myocardial tissue?
Martonová, D., Leyendecker, S., Holzapfel, G. A., & Ellen Kuhl, A. (2025) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-02005-x · Cited by 9
Ovcharenko, E. A., Klyshnikov, K. Y., Savrasov, G. V., Викторович, Б. А., Ganykov, V. I., Коков, А. Н., Нуштаев, Д. В., Dolgov, V. Y., Kudryavtseva, Y. А., & Barbarash, L. S. (2016) · Современные технологии в медицине · doi:10.17691/stm2016.8.1.11 · Cited by 9
Wisneski, A. D., Wang, Y., Cutugno, S., Pasta, S., Stroh, A., Jiang, Y. D., Nguyen, T. C., Mahadevan, V. S., & Guccione, J. M. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.848011 · Cited by 9
Living Heart Human Model: Cardiovascular Stent Deployment and Cardiac Cycle Simulation1
Saraswat, P., Chinnakonda, M., & Baillargeon, B. P. (2016) · Journal of Medical Devices · doi:10.1115/1.4033869 · Cited by 9
Self-citationStructure Tensors for Dispersed Fibers in Soft Materials
Kalhöfer-Köchling, M., Bodenschatz, E., & Wang, Y. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.13.064039 · Cited by 8
Weissmann, J., Charles, C. J., Richards, M., Yap, C. H., & Marom, G. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104937 · Cited by 9
Galili, L., Zeira, A. W., & Marom, G. (2022) · Royal Society Open Science · doi:10.1098/rsos.211464 · Cited by 9
Towards an efficient computational strategy for electro-activation in cardiac mechanics
Garcia-Blanco, E., Ortigosa, R., Gil, A. J., & Bonet, J. (2019) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.06.042 · Cited by 9
Torbati, S., Daneshmehr, A. R., Pouraliakbar, H., Asgharian, M., Tafti, S. H. A., Tim, D. S., & Heidari, A. (2024) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-024-01856-0 · Cited by 8
Huang, X., Deng, L., Zuo, H., Yang, C., Song, Y., Lesperance, M., & Tang, D. (2021) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-00838-4 · Cited by 8
Marom, G., Mayo, R. P., Again, N., & Raanani, E. (2021) · Innovations Technology and Techniques in Cardiothoracic and Vascular Surgery · doi:10.1177/1556984521999362 · Cited by 8
Rosli, N. A. K., Adib, M. A. H. M., Sukri, N. N. M., Sahat, I. M., & Hasni, N. H. M. (2021) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes48179.2021.9398731 · Cited by 8
How viscous is the beating heart? Insights from a computational study
Tikenoğulları, O. Z., Costabal, F. S., Jiang, Y. D., Marsden, A. L., & Ellen Kuhl, A. (2022) · Computational Mechanics · doi:10.1007/s00466-022-02180-z · Cited by 8
Design and Modeling of a Soft Artificial Heart by Using the SolidWorks and ANSYS
Ali, S., Ali, Z. J., & Mahde, M. (2020) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/671/1/012062 · Cited by 8
Roy, R., Warren, E., Xu, Y., Yow, C., Madhurapantula, R. S., Orgel, J. P. R. O., & Lister, K. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21186503 · Cited by 8
The hemodynamic power of the heart differentiates normal from diseased right ventricles
Pedrizzetti, G., Faganello, G., Croatto, E., & Lenarda, A. D. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110312 · Cited by 8
Personalized biventricular mechanics and sensitivity to model morphology
Brown, A. L., Shi, L., Salvador, M., Kong, F., Ennis, D. B., Chen, I. Y., Vedula, V., & Marsden, A. L. (2026) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-026-02127-w · Cited by 7
Holz, D., Martonová, D., Schaller, E., Dương, M. T., Alkassar, M., Weyand, M., & Leyendecker, S. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111643 · Cited by 7
Physical model of end-diastolic and end-systolic pressure-volume relationships of a heart
Zhang, Y., Kalhöfer-Köchling, M., Bodenschatz, E., & Wang, Y. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1195502 · Cited by 7
A virtual scalable model of the Hepatic Lobule for acetaminophen hepatotoxicity prediction
Pinto, S. C. D., Cherkaoui, J., Ghosh, D., Cazaubon, V., Benzeroual, K. E., Levine, S. M., Cherkaoui, M., Sood, G., Anandasabapathy, S., Dhingra, S., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01349-5 · Cited by 8
Computer modeling and simulation of heart valve function and intervention
Sun, W., Mao, W., & Griffith, B. E. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814661-3.00007-1 · Cited by 7
Metadata
- Authors
- Baillargeon, B., Rebelo, N., Fox, D. D., Taylor, R. L., & Kuhl, E.
- Affiliations
- Dassault Systèmes (United States) (US)
- ORCID
- Kuhl, Ellen
- Venue
- European Journal of Mechanics - A/Solids
- Publisher
- Elsevier BV
- Published
- 2014-11
- Volume
- 48
- Pages
- 38-47
- ISSN
- 0997-7538 (ISSN-L)
- PMC
- PMC4175454
- OpenAlex
- W2131414969
- Cited by
- 370
- References
- 53
- Citations by year
- 2026: 33 · 2025: 38 · 2024: 40 · 2023: 37 · 2022: 43 · 2021: 38 · 2020: 29 · 2019: 27 · 2018: 34 · 2017: 18 · 2016: 12 · 2015: 17 · 2014: 4
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- European Journal of Mechanics - A/Solids (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health (U54 GM072970)
- National Science Foundation (CMMI 0952021, 1233054)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Physical Sciences › Engineering › Computational Mechanics › Advanced Numerical Methods in Computational Mathematics
- Keywords
- electromechanical coupling, excitation-contraction coupling, cardiac simulation, cardiac cycle, pressure-volume relationship, heart valves, magnetic resonance imaging, finite element model, heart disease, valve stenosis, valvular regurgitation, mitral valve prolapse
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review