CoChat

Augmentative Repetitive Transcranial Magnetic Stimulation (rTMS) in the Acute Treatment of Poor Responder Depressed Patients: A Comparison Study Between High and Low Frequency Stimulation

Dell’Osso, B., Oldani, L., Camuri, G., Dobrea, C., Cremaschi, L., Benatti, B., Arici, C., Grancini, B., Carlo Altamura, A. · 2015 · European Psychiatry
Cited by 44

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Background: While the efficacy of repetitive transcranial magnetic stimulation (rTMS) in Major Depressive Disorder (MDD) is well established, the debate is still open in relation to bipolar depression and to a possible different effectiveness of high vs. low stimulation. The present study was aimed to assess and compare the efficacy and tolerability of different protocols of augmentative rTMS in a sample of patients with current Major Depressive Episode (MDE), poor drug response/treatment resistance and a diagnosis of MDD or bipolar disorder. Methods: Thirty-three patients were recruited in a 4-week, blind-rater, rTMS trial and randomised to the following three groups of stimulation: (1) (n = 10) right dorsolateral prefrontal cortex (DLPFC) 1 HZ, 110% of the motor threshold (MT), 420 stimuli/day; (2) (n = 10) right DLPFC, 1 Hz, 110% MT, 900 stimuli/day; (3) (n = 13) left DLPFC, 10 Hz, 80% MT, 750 stimuli/day. Results: Twenty-nine patients completed the treatment, showing a significant reduction of primary outcome measures (HAM-D, MADRS and CGI-S total scores: t = 8.1, P < 0.001; t = 8.6, P < 0.001; t = 4.6, P < 0.001 respectively). No significant differences in terms of efficacy and tolerability were found between high vs. low frequency and between unipolar and bipolar patients. Side effects were reported by 21% of the sample. One of the 4 dropouts was caused by a hypomanic switch. Conclusions: Augmentative rTMS appeared to be effective and well tolerated for the acute treatment of unipolar and bipolar depression with features of poor drug response/treatment resistance, showing a comparable effectiveness profile between protocols of high and low frequency stimulation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.eurpsy.2014.12.001

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Dell’Osso, B., Oldani, L., Camuri, G., Dobrea, C., Cremaschi, L., Benatti, B., Arici, C., Grancini, B., & Carlo Altamura, A.
Venue
European Psychiatry
Published
2015-02
Volume
30
Issue
2
Pages
271-276
ISSN
  • 0924-9338 (ISSN-L)
  • 1778-3585
OpenAlex
W1995187678
Cited by
44
References
6
FWCI
2.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.