The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Serum Levels of MicroRNA miR-371a-3p: A Sensitive and Specific New Biomarker for Germ Cell Tumours
Open accessAbstract
BACKGROUND: Clinical management of germ cell tumours (GCTs) relies on monitoring of serum tumour markers. However, the markers α-fetoprotein (AFP), the β-subunit of human chorionic gonadotropin (bHCG), and lactate dehydrogenase (LDH) are expressed in <60% of GCT cases. OBJECTIVE: To test the utility of the microRNAs (miRNAs) miR-371a-3p, miR-372-3p, miR-373-3p, and miR-367-3p as sensitive and specific GCT serum biomarkers. DESIGN, SETTING, AND PARTICIPANTS: Serum levels of miRNAs were measured in 166 consecutive patients with GCT before and after treatment and in 106 male controls. In the first 50 consecutive patients, all four miRNAs were measured. In the main study, only the most sensitive miRNA was further analysed. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: The specificity and sensitivity of the four miRNAs were studied using receiver operating characteristic curves. miRNA sensitivities were compared to those of classical markers. Statistical cross-comparisons of miRNA levels for GCT subgroups and controls were performed at various time points during treatment. RESULTS AND LIMITATIONS: Overall, miR-371a-3p performed best, with 88.7% sensitivity (95% confidence interval [CI] 82.5-93.3%) and 93.4% specificity (95% CI 86.9-97.3%) and an area under the curve of 0.94, outperforming AFP, bHCG, and LDH (combined sensitivity 50%). According to Kernel density estimation, the sensitivity and specificity were 86.3% and 92.5%, respectively. miR-371a-3p levels dropped to normal after completion of treatment. The miRNA levels correlated with treatment failure and relapse. Teratoma did not express miR-371a-3p. CONCLUSIONS: The miRNA miR-371a-3p is a specific and sensitive novel serum GCT biomarker that accurately correlates with disease activity. Validation of this test in a large-scale prospective study is needed. PATIENT SUMMARY: miR-371a-3p is a novel serum marker for germ cell tumours that is expressed by 88.7% of patients and thus is far more sensitive and specific than classical serum markers. It correlates with tumour burden and treatment results. Validation in a large patient cohort is needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments
Bustin, S. A., Benes, V., Garson, J. A., Hellemans, J., Huggett, J., Kubista, M., Mueller, R., Nolan, T., Pfaffl, M. W., Shipley, G. L., et al. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.112797 · Cited by 16,303 · cited 1×
“Details of the measurement methods are described in the Supplementary methods [19].”
Method
Cited by
Integrated Molecular Characterization of Testicular Germ Cell Tumors
Shen, H., Shih, J., Hollern, D. P., Wang, L., Bowlby, R., Tickoo, S. K., Thorsson, V., Mungall, A. J., Newton, Y., Hegde, A. M., et al. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.05.039 · Cited by 454
Metadata
- Authors
- Dieckmann, K.-P., Radtke, A., Spiekermann, M., Balks, T., Matthies, C., Becker, P., Ruf, C., Oing, C., Oechsle, K., Bokemeyer, C., Hammel, J., Melchior, S., Wosniok, W., & Belge, G.
- Venue
- European Urology
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 71
- Issue
- 2
- Pages
- 213-220
- ISSN
- 0302-2838 (ISSN-L)
- OpenAlex
- W2504019010
- Cited by
- 209
- References
- 1
- FWCI
- 19.91
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Serum Levels of MicroRNA miR-371a-3p: A Sensitive and Specific New Biomarker for Germ Cell Tumours. https://app.cochat.ai/papers/10.1016/j.eururo.2016.07.029
- The paper
- Dieckmann, K.-P., Radtke, A., Spiekermann, M., Balks, T., Matthies, C., Becker, P., Ruf, C., Oing, C., Oechsle, K., Bokemeyer, C., Hammel, J., Melchior, S., Wosniok, W., & Belge, G. (2017). Serum Levels of MicroRNA miR-371a-3p: A Sensitive and Specific New Biomarker for Germ Cell Tumours. European Urology. https://doi.org/10.1016/j.eururo.2016.07.029
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.