The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibers heated to high temperatures
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High-temperature behaviour of HPC with polypropylene fibres
Kalifa, P., Chéné, G., & Gallé, C. (2001) · Cement and Concrete Research · doi:10.1016/s0008-8846(01)00596-8 · Cited by 752
State of the Art Report on High-Strength Concrete
ACI Committee (1984) · ACI Journal Proceedings · doi:10.14359/10692 · Cited by 622
Concrete at High Temperatures: Material Properties and Mathematical Models
Bažant, Z. P., & Kaplan, M. F. (1996) · Medical Entomology and Zoology · Cited by 608
Poon, C.-S., Azhar, S., Anson, M., & Wong, Y.-L. (2001) · Cement and Concrete Research · doi:10.1016/s0008-8846(01)00580-4 · Cited by 521
Poon, C. S., Shui, Z. H., & Lam, L. (2004) · Cement and Concrete Research · doi:10.1016/j.cemconres.2004.02.011 · Cited by 455
Chen, B., & Liu, J. (2004) · Cement and Concrete Research · doi:10.1016/j.cemconres.2003.11.010 · Cited by 375
Behnood, A., & Ziari, H. (2008) · Cement and Concrete Composites · doi:10.1016/j.cemconcomp.2007.06.003 · Cited by 349
Self-citationMechanical properties of high-strength concrete after fire
Li, M., Qian, C., & Sun, W. (2004) · Cement and Concrete Research · doi:10.1016/j.cemconres.2003.11.007 · Cited by 341
Chan, Y. N., Luo, X., & Sun, W. (2000) · Cement and Concrete Research · doi:10.1016/s0008-8846(99)00240-9 · Cited by 327
Shrinkage Cracking of Fiber Reinforced Concrete
Grzybowski, M., & Shah, S. P. (1990) · ACI Materials Journal · doi:10.14359/1951 · Cited by 315
Cited by
Properties of Concrete at Elevated Temperatures
Kodur, V. (2014) · ISRN Civil Engineering · doi:10.1155/2014/468510 · Cited by 683
Malik, M., Bhattacharyya, S. K., & Barai, S. V. (2021) · Construction and Building Materials · doi:10.1016/j.conbuildmat.2020.121398 · Cited by 259
Gupta, S., Kua, H. W., & Tan Cynthia, S. Y. (2017) · Cement and Concrete Composites · doi:10.1016/j.cemconcomp.2017.07.012 · Cited by 126
Metadata
- Authors
- Behnood, A., & Ghandehari, M.
- Venue
- Fire Safety Journal
- Publisher
- Elsevier BV
- Published
- 2009-11
- Volume
- 44
- Issue
- 8
- Pages
- 1015-1022
- ISSN
- 0379-7112 (ISSN-L)
- OpenAlex
- W2047383265
- Cited by
- 350
- References
- 24
- FWCI
- 18.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibers heated to high temperatures. https://app.cochat.ai/papers/10.1016/j.firesaf.2009.07.001
- The paper
- Behnood, A., & Ghandehari, M. (2009). Comparison of compressive and splitting tensile strength of high-strength concrete with and without polypropylene fibers heated to high temperatures. Fire Safety Journal. https://doi.org/10.1016/j.firesaf.2009.07.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.