The DOI matches its Crossref record; the references it cites are not checked yet.
Using passive cooling strategies to improve thermal performance and reduce energy consumption of residential buildings in U.A.E. buildings
Open accessAbstract
Passive design responds to local climate and site conditions in order to maximise the comfort and health of building users while minimising energy use. The key to designing a passive building is to take best advantage of the local climate. Passive cooling refers to any technologies or design features adopted to reduce the temperature of buildings without the need for power consumption. Consequently, the aim of this study is to test the usefulness of applying selected passive cooling strategies to improve thermal performance and to reduce energy consumption of residential buildings in hot arid climate settings, namely Dubai, United Arab Emirates. One case building was selected and eight passive cooling strategies were applied. Energy simulation software – namely IES – was used to assess the performance of the building. Solar shading performance was also assessed using Sun Cast Analysis, as a part of the IES software. Energy reduction was achieved due to both the harnessing of natural ventilation and the minimising of heat gain in line with applying good shading devices alongside the use of double glazing. Additionally, green roofing proved its potential by acting as an effective roof insulation. The study revealed several significant findings including that the total annual energy consumption of a residential building in Dubai may be reduced by up to 23.6% when a building uses passive cooling strategies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Passive cooling strategies can reduce cooling load by 9%.
“The passive cooling strategies can also reduce the cooling load by 9% and even reduce energy consumption by around 24% [95].”
From Heatwaves in South Asia: Characterization, Consequences on Human Health, and Adaptation Strategies (2022) · cites this paper as [95]
Passive cooling strategies can reduce energy consumption by around 24%.
“The passive cooling strategies can also reduce the cooling load by 9% and even reduce energy consumption by around 24% [95].”
From Heatwaves in South Asia: Characterization, Consequences on Human Health, and Adaptation Strategies (2022) · cites this paper as [95]
Citations
The citation lists haven’t been fetched yet
References 19 · Cited by 263
Research works printed but not linked: 15
- Aboulnaga, 1998, A roof solar chimney assisted by cooling cavity for natural ventilation in buildings in hot arid climates: an energy conservation approach in Al-Ain city, Renew. Energy, 4, 357, 10.1016/S0960-1481(98)00090-1 · DOI
- Al-Sallal, 2012, Outdoor airflow analysis and potential for passive cooling in the modern urban context of Dubai, Renew. Energy, 38, 40, 10.1016/j.renene.2011.06.046 · DOI
- Al-Sallal, 2013, Designing a sustainable house in the desert of Abu Dhabi, Renew. Energy, 49, 80, 10.1016/j.renene.2012.01.061 · DOI
- El-Sherif, S.K., 2012. The Impact of Overhangs and Side-fins on Building Thermal Comfort, Visual Comfort and Energy Consumption in the Tropics (MSc thesis), British University in Dubai.
- Ghazal-Aswad, 2012, Clean energy awareness campaigns in the UAE: an awareness promoters perspective, Int. J. Innovation Knowl. Manag. MENA, 2, 131
- Gong, 2012, Optimization of passive design measures for residential buildings in different Chinese areas, Build. Environ., 58, 46, 10.1016/j.buildenv.2012.06.014 · DOI
- Hughes, 2012, The development of commercial wind towers for natural ventilation: a review, Appl. Energy, 92, 606, 10.1016/j.apenergy.2011.11.066 · DOI
- Jaffal, 2012, A comprehensive study of the impact of green roofs on building energy performance, Renew. Energy, 43, 157, 10.1016/j.renene.2011.12.004 · DOI · Paper page
- Liotsios, K., 2012. 3D Modeling and Energy Simulation of a Single Family House in Southern Greece (MSc thesis), KTH School of Architecture and the Built Environment.
- Noh-Pat, 2001, Thermal analysis for a double glazing unit with and without a solar control film (SnS–CuxS) for using in hot climates, Energy Build., 43, 704, 10.1016/j.enbuild.2010.11.015 · DOI
- Qui, 2006, Novel design and modeling of an evaporative cooling system for buildings, Int. J. Energy Res., 30, 985, 10.1002/er.1199 · DOI
- Rahman, M.M., Rasul, M.G. Khan, M.M.K., 2008. Energy conservation measures in an institutional building by dynamic simulation using DesignBuilder. In: Third International Conference on Energy and Environment, Cambridge, 23–25 February.
- Sadrzadehrafiei, 2011, Determining the cost saving and emission reduction of optimum insulation thickness and air gap for building wall, Aust. J. Basic Appl. Sci., 5, 2287
- Shen, 2001, The effect of reflective coatings on building surface temperature, indoor environment and energy consumption, Energy Build., 43, 573, 10.1016/j.enbuild.2010.10.024 · DOI
- Tiwari, 1994, Comparison of passive cooling techniques, Build. Environ., 29, 21, 10.1016/0360-1323(94)90049-3 · DOI
Metadata
- Authors
- Taleb, H. M.
- Affiliations
- British University in Dubai (AE)
- Corresponding author
- Taleb, Hanan M.
- ORCID
- Taleb, Hanan M.
- Venue
- Frontiers of Architectural Research
- Publisher
- Elsevier BV
- Published
- 2014-06
- Volume
- 3
- Issue
- 2
- Pages
- 154-165
- ISSN
- 2095-2635 (ISSN-L)
- OpenAlex
- W2133934944
- Cited by
- 263
- References
- 19
- Citations by year
- 2026: 18 · 2025: 19 · 2024: 41 · 2023: 29 · 2022: 23 · 2021: 39 · 2020: 26 · 2019: 22 · 2018: 16 · 2017: 17 · 2016: 9 · 2015: 2 · 2014: 2
- FWCI
- 14.83
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Frontiers of Architectural Research (publishedVersion, cc-by-nc-nd)
- LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas) (submittedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Physical Sciences › Engineering › Building and Construction › Solar Energy Systems and Technologies
- Physical Sciences › Engineering › Building and Construction › Building energy efficiency and sustainability
- Keywords
- passive cooling, residential buildings, building energy consumption, thermal performance, hot arid climate, natural ventilation, solar shading, double glazing, green roofs, roof insulation, building energy simulation, Dubai
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review